scholarly journals Multifeature Extraction of Three-Dimensional Topography of Carbon Steel Specimen during Fatigue Process

2021 ◽  
Vol 2021 ◽  
pp. 1-15
Author(s):  
Tao Liu ◽  
Jingxiong Wu ◽  
Jingfa Lei ◽  
Xue Wang ◽  
Bingqi Zhang ◽  
...  

In order to investigate the variation of three-dimensional metal surface topography during fatigue process, a three-dimensional (3D) topography acquisition platform was built with an in situ tensile tester and a three-dimensional profilometer. Q235 steel specimens were chosen as research objects, and the three-dimensional surface topography information at various stages of fatigue damage was obtained. Through the characterization of three-dimensional roughness, combined with surface height distribution and multifractal analysis, the variations of metal surface topography in the fatigue process were described. Results show that the arithmetic mean deviation of the surface (Sa), the width of the multifractal spectrum (Δα), and the mean value of surface height distribution (μ) and its standard deviation (δ) increase nonlinearly with the increase of fatigue cycles. The rate of fatigue damage is slow in the early stage and high in the middle and late stages. The surface height distribution amplitude (A) decreases with the increase of fatigue cycles, which indicates that the height data concentration decreases, and the metal surface becomes uneven. The Bayesian data fusion method was applied to establish a nonlinear mapping between the topography features and the damage, with the above five characteristic parameters (Sa, Δα, A, μ, and δ) as the data layer. Finally, a surface topography feature fusion method is proposed, and a case study is conducted to verify its applicability. The research results can provide reference for fatigue damage assessment.

Materials ◽  
2019 ◽  
Vol 12 (17) ◽  
pp. 2762 ◽  
Author(s):  
Ruimin Shi ◽  
Bukang Wang ◽  
Zhiwei Yan ◽  
Zongyan Wang ◽  
Lei Dong

In order to explore the relationship between the surface topography parameters and friction properties of a rough contact interface under fluid dynamic pressure lubrication conditions, friction experiments were carried out. The three-dimensional surface topography of specimens was measured and characterized with a profile microscopy measuring system and scanning electron microscope. The friction coefficient showed a trend of decreasing first and then increasing with the increase in some surface topography parameters at lower pressure, such as the surface height arithmetic mean Sa, surface height distribution kurtosis Sku, surface volume average volume Vvv, and surface center area average void volume Vvc, which are the ISO 25178 international standard parameters. The effects of surface topographic parameters on friction were analyzed and the wear mechanism of the worn surface was presented. The wear characteristics of the samples were mainly characterized as strain fatigue, grinding, and scraping. The results provide a theoretical basis for the functional characterization of surface topography.


Author(s):  
Michelle Carvalho de Sales ◽  
Rafael Maluza Flores ◽  
Julianny da Silva Guimaraes ◽  
Gustavo Vargas da Silva Salomao ◽  
Tamara Kerber Tedesco ◽  
...  

Dental surgeons need in-depth knowledge of the bone tissue status and gingival morphology of atrophic maxillae. The aim of this study is to describe preoperative virtual planning of placement of five implants and to compare the plan with the actual surgical results. Three-dimensional planning of rehabilitation using software programs enables surgical guides to be specially designed for the implant site and manufactured using 3D printing. A patient with five teeth missing was selected for this study. The patient’s maxillary region was scanned with CBCT and a cast model was produced. After virtual planning using ImplantViewer, five implants were placed using a printed surgical guide. Two weeks after the surgical procedure, the patient underwent another CBCT scan of the maxilla. Statistically significant differences were detected between the virtually planned positions and the actual positions of the implants, with a mean deviation of 0.36 mm in the cervical region and 0.7 mm in the apical region. The surgical technique used enables more accurate procedures when compared to the conventional technique. Implants can be better positioned, with a high level of predictability, reducing both operating time and patient discomfort.


2019 ◽  
Vol 63 (5) ◽  
pp. 50402-1-50402-9 ◽  
Author(s):  
Ing-Jr Ding ◽  
Chong-Min Ruan

Abstract The acoustic-based automatic speech recognition (ASR) technique has been a matured technique and widely seen to be used in numerous applications. However, acoustic-based ASR will not maintain a standard performance for the disabled group with an abnormal face, that is atypical eye or mouth geometrical characteristics. For governing this problem, this article develops a three-dimensional (3D) sensor lip image based pronunciation recognition system where the 3D sensor is efficiently used to acquire the action variations of the lip shapes of the pronunciation action from a speaker. In this work, two different types of 3D lip features for pronunciation recognition are presented, 3D-(x, y, z) coordinate lip feature and 3D geometry lip feature parameters. For the 3D-(x, y, z) coordinate lip feature design, 18 location points, each of which has 3D-sized coordinates, around the outer and inner lips are properly defined. In the design of 3D geometry lip features, eight types of features considering the geometrical space characteristics of the inner lip are developed. In addition, feature fusion to combine both 3D-(x, y, z) coordinate and 3D geometry lip features is further considered. The presented 3D sensor lip image based feature evaluated the performance and effectiveness using the principal component analysis based classification calculation approach. Experimental results on pronunciation recognition of two different datasets, Mandarin syllables and Mandarin phrases, demonstrate the competitive performance of the presented 3D sensor lip image based pronunciation recognition system.


BMJ Open ◽  
2021 ◽  
Vol 11 (2) ◽  
pp. e041427
Author(s):  
Biming He ◽  
Rongbing Li ◽  
Dongyang Li ◽  
Liqun Huang ◽  
Xiaofei Wen ◽  
...  

IntroductionThe classical pathway for diagnosing prostate cancer is systematic 12-core biopsy under the guidance of transrectal ultrasound, which tends to underdiagnose the clinically significant tumour and overdiagnose the insignificant disease. Another pathway named targeted biopsy is using multiparametric MRI to localise the tumour precisely and then obtain the samples from the suspicious lesions. Targeted biopsy, which is mainly divided into cognitive fusion method and software-based fusion method, is getting prevalent for its good performance in detecting significant cancer. However, the preferred targeted biopsy technique in detecting clinically significant prostate cancer between cognitive fusion and software-based fusion is still beyond consensus.Methods and analysisThis trial is a prospective, single-centre, randomised controlled and non-inferiority study in which all men suspicious to have clinically significant prostate cancer are included. This study aims to determine whether a novel three-dimensional matrix positioning cognitive fusion-targeted biopsy is non-inferior to software-based fusion-targeted biopsy in the detection rate of clinically significant cancer in men without a prior biopsy. The main inclusion criteria are men with elevated serum prostate-specific antigen above 4–20 ng/mL or with an abnormal digital rectal examination and have never had a biopsy before. A sample size of 602 participants allowing for a 10% loss will be recruited. All patients will undergo a multiparametric MRI examination, and those who fail to be found with a suspicious lesion, with the anticipation of half of the total number, will be dropped. The remaining participants will be randomly allocated to cognitive fusion-targeted biopsy (n=137) and software-based fusion-targeted biopsy (n=137). The primary outcome is the detection rate of clinically significant prostate cancer for cognitive fusion-targeted biopsy and software-based fusion-targeted biopsy in men without a prior biopsy. The clinically significant prostate cancer will be defined as the International Society of Urological Pathology grade group 2 or higher.Ethics and disseminationEthical approval was obtained from the ethics committee of Shanghai East Hospital, Tongji University School of Medicine, Shanghai, China. The results of the study will be disseminated and published in international peer-reviewed journals.Trial registration numberClinicalTrials.gov Registry (NCT04271527).


2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Annarita Perillo ◽  
Valeria Landoni ◽  
Alessia Farneti ◽  
Giuseppe Sanguineti

Abstract Purpose The purpose of this study is to evaluate inter- and intra-fraction organ motion as well as to quantify clinical target volume (CTV) to planning target volume (PTV) margins to be adopted in the stereotactic treatment of early stage glottic cancer. Methods and materials Stereotactic body radiotherapy (SBRT) to 36 Gy in 3 fractions was administered to 23 patients with early glottic cancer T1N0M0. Patients were irradiated with a volumetric intensity modulated arc technique delivered with 6 MV FFF energy. Each patient underwent a pre-treatment cone beam computed tomography (CBCT) to correct the setup based on the thyroid cartilage position. Imaging was repeated if displacement exceeded 2 mm in any direction. CBCT imaging was also performed after each treatment arc as well as at the end of the delivery. Swallowing was allowed only during the beam-off time between arcs. CBCT images were reviewed to evaluate inter- and intra-fraction organ motion. The relationships between selected treatment characteristics, both beam-on and delivery times as well as organ motion were investigated. Results For the population systematic (Ʃ) and random (σ) inter-fraction errors were 0.9, 1.3 and 0.6 mm and 1.1, 1.3 and 0.7 mm in the left-right (X), cranio-caudal (Y) and antero-posterior (Z) directions, respectively. From the analysis of CBCT images acquired after treatment, systematic (Ʃ) and random (σ) intra-fraction errors resulted 0.7, 1.6 and 0.7 mm and 1.0, 1.5 and 0.6 mm in the X, Y and Z directions, respectively. Margins calculated from the intra-fraction errors were 2.4, 5.1 and 2.2 mm in the X, Y and Z directions respectively. A statistically significant difference was found for the displacement in the Z direction between patients irradiated with > 2 arcs versus ≤ 2 arcs, (MW test, p = 0.038). When analyzing mean data from CBCT images for the whole treatment, a significant correlation was found between the time of delivery and the three dimensional displacement vector (r = 0.489, p = 0.055), the displacement in the Y direction (r = 0.553, p = 0.026) and the subsequent margins to be adopted (r = 0.626, p = 0.009). Finally, displacements and the subsequent margins to be adopted in Y direction were significantly greater for treatments with more than 2 arcs (MW test p = 0.037 and p = 0.019, respectively). Conclusions In the setting of controlled swallowing during treatment delivery, intra-fraction motion still needs to be taken into account when planning with estimated CTV to PTV margins of 3, 5 and 3 mm in the X, Y and Z directions, respectively. Selected treatments may require additional margins.


2020 ◽  
Vol 11 (1) ◽  
pp. 301
Author(s):  
Sławomir Paśko ◽  
Wojciech Glinkowski

Scoliosis is a three-dimensional trunk and spinal deformity. Patient evaluation is essential for the decision-making process and determines the selection of specific and adequate treatment. The diagnosis requires a radiological evaluation that exposes patients to radiation. This exposure reaches hazardous levels when numerous, repetitive radiographic studies are required for diagnostics, monitoring, and treatment. Technological improvements in radiographic devices have significantly reduced radiation exposure, but the risk for patients remains. Optical three-dimensional surface topography (3D ST) measurement systems that use surface topography (ST) to screen, diagnose, and monitor scoliosis are safer alternatives to radiography. The study aimed to show that the combination of plain X-ray and 3D ST scans allows for an approximate presentation of the vertebral column spinous processes line in space to determine the shape of the spine’s deformity in scoliosis patients. Twelve patients diagnosed with scoliosis, aged 13.1 ± 4.5 years (range: 9 to 20 years) (mean: Cobb angle 17.8°, SD: ±9.5°) were enrolled in the study. Patients were diagnosed using full-spine X-ray and whole torso 3D ST. The novel three-dimensional assessment of the spinous process lines by merging 3D ST and X-ray data in patients with scoliosis was implemented. The method’s expected uncertainty is less than 5 mm, which is better than the norm for a standard measurement tool. The presented accuracy level is considered adequate; the proposed solution is accurate enough to monitor the changes in the shape of scoliosis’s spinous processes line. The proposed method allows for a relatively precise calculation of the spinous process lines based on a three-dimensional point cloud obtained with a four-directional, three-dimensional structured light diagnostic system and a single X-ray image. The method may help reduce patients’ total radiation exposure and avoid one X-ray in the sagittal projection if biplanar radiograms are required for reconstructing the three-dimensional line of the spinous processes line.


2021 ◽  
Vol 10 (2) ◽  
pp. 184
Author(s):  
Maximilian Kerschbaum ◽  
Siegmund Lang ◽  
Florian Baumann ◽  
Volker Alt ◽  
Michael Worlicek

Insertion of sacro-iliac (SI) screws for stabilization of the posterior pelvic ring without intraoperative navigation or three-dimensional imaging can be challenging. The aim of this study was to develop a simple method to visualize the ideal SI screw corridor, on lateral two-dimensional images, corresponding to the lateral fluoroscopic view, used intraoperatively while screw insertion, to prevent neurovascular injury. We used multiplanar reconstructions of pre- and postoperative computed tomography scans (CT) to determine the position of the SI corridor. Then, we processed the dataset into a lateral two-dimensional slice fusion image (SFI) matching head and tip of the screw. Comparison of the preoperative SFI planning and the screw position in the postoperative SFI showed reproducible results. In conclusion, the slice fusion method is a simple technique for translation of three-dimensional planned SI screw positioning into a two-dimensional strict lateral fluoroscopic-like view.


Sign in / Sign up

Export Citation Format

Share Document