scholarly journals Validation Study to Determine the Accuracy of Central Blood Pressure Measurement Using the Sphygmocor Xcel Cuff Device

Hypertension ◽  
2020 ◽  
Vol 76 (1) ◽  
pp. 244-250 ◽  
Author(s):  
Martin G. Schultz ◽  
Dean S. Picone ◽  
Matthew K. Armstrong ◽  
J. Andrew Black ◽  
Nathan Dwyer ◽  
...  

Numerous devices purport to measure central (aortic) blood pressure (BP) as distinct from conventional brachial BP. This validation study aimed to determine the accuracy of the Sphygmocor Xcel cuff device (AtCor Medical, CardieX, Sydney, Australia) for measuring central BP. 296 patients (mean age 61±12 years) undergoing coronary angiography had simultaneous measurement of invasive central BP and noninvasive cuff-derived central BP using the Xcel cuff device (total n=558 individual comparisons). A subsample (n=151) also had invasive brachial BP measured. Methods were undertaken according to the Artery Society recommendations, and several calibration techniques to derive central systolic BP (SBP) were examined. Minimum acceptable error was ≤5±≤8 mm Hg. Central SBP was significantly underestimated, and with wide variability, when using the default calibration of brachial-cuff SBP and diastolic BP (DBP; mean difference±SD, −7.7±11.0 mm Hg). Similar variability was observed using other calibration methods (cuff 33% form-factor mean arterial pressure and DBP, −4.4±11.5 mm Hg; cuff 40% form-factor mean arterial pressure and DBP, 4.7±11.9 mm Hg; cuff oscillometric mean arterial pressure and DBP, −18.2±12.1 mm Hg). Only calibration with invasive central integrated mean arterial pressure and DBP was within minimal acceptable error (3.3±7.5 mm Hg). The difference between brachial-cuff SBP and invasive central SBP was 3.3±10.7 mm Hg. A subsample analysis to determine the accuracy of central-to-brachial SBP amplification showed this to be overestimated by the Xcel cuff device (mean difference 4.3±9.1 mm Hg, P =0.02). Irrespective of cuff calibration technique, the Sphygmocor Xcel cuff device does not meet the Artery Society accuracy criteria for noninvasive measurement of central BP.

Author(s):  
Sidonia Alina BOGDAN ◽  
Vlad LUCA ◽  
Cosmin PESTEAN ◽  
Ciprian OBER ◽  
Lucia BEL ◽  
...  

Experimental studies on small lab animals, particularly rats are a widely-used model (Ordodi et. all 2004). Blood pressure measurement is one of the fastest and most informative means of assessing cardiovascular function and provides an accurate indication of drug effects, surgical events and hemodynamic trends (Tranquilli et. all, 2007). A close monitoring of the animals during the experiment is important to detect early imbalances and prevent any changes that could compromise the results.Blood pressure measurement is one of the basic procedures in biomedical research and it can be done by non-invasive or invasive technics. The gold standard procedures with the most accuracy are the invasive technics. This includes radial, femoral, brachial or carotid cannulation (Parasuraman et. all 2012). Carotid artery catheterization is a common procedure that allows precise monitoring of the blood pressure but surgery is required to perform them (Plehm et. all 2006).Experimental surgery on small lab animals, especially rats, it’s a widely used model. In order to perform surgery, anaesthesia must be used and it usually causes a slowdown of the respiration that induces metabolic imbalances. It could cause cardiovascular collapse and death if left unbalanced. A close monitoring of the respiration, ECG, blood pressure is necessary during the experiment (Ordodi et. all 2004).Because it may not be always available or the prohibitive cost of the special equipment used to perform these tasks, we adapted a simple device and method to record the mean arterial pressure (MAP) in rats by carotid catheterisation and the results obtained were sustainable.


Author(s):  
Jordan N Yolles ◽  
Robyn B Lee-Stubbs

Quantitative blood pressure measurement is a critical parameter for assessing cardiovascular health, monitoring physiologic status under anesthesia, and making clinical decisions. The placement of an arterial catheter is the most accurate way to measure blood pressure, but is invasive and perhaps uncomfortable for the patient, requires sedation or anesthesia, and is technically challenging for staff. Noninvasive devices and methods, including oscillometry, high-definition oscillometry, and Doppler flow can be used to measure blood pressure. However, the American College of Veterinary Internal Medicine guidelines state that blood pressure should be measured using devices that have been validated in the species of interest and under the circumstances in which the measurement is being made. The alternatives listed above have not been validated in this manner. The objective of this study was to compare indirect ultrasonic Doppler flow detection and oscillometric blood pressure measures with direct arterial measurement in 8 healthy, anesthetized African green monkeys using the methods of Bland-Altman to assess agreement. Our results indicated that neither Doppler flow nor oscillometry consistently estimates direct blood pressure measurements in anesthetized African green monkeys. In 6 female monkeys, which weighed less than the 2 male subjects, the indirect Doppler measurement more closely predicted direct mean arterial pressure, indicating Dop- pler flow may be useful for monitoring mean arterial pressure in small patients.


Author(s):  
M.A. Bubnova ◽  
O.N. Kryuchkova

Patients with hypertension (HT) and chronic obstructive pulmonary disease (COPD) have a high risk of cardiovascular complications. Up to now, there is no optimal strategy for combined antihypertensive therapy. Still, the data of 24-hour blood pressure monitoring (BPM) are important while choosing treatment tactics. The aim of the paper is to study the features of indicators in patients with arterial hypertension (AH) and COPD. Materials and methods. 130 patients with HT were included in the study. The main group (n=90) included comorbid patients with HT and COPD, their average age was 61.30±1.01; the comparison group (n=40) consisted of patients with HT, their average age was 59.10±1.53. All patients underwent 24-hour BPM. Results. Comorbid patients revealed an increase in the mean 24-hour and night systolic and mean arterial pressure values as well as a significant increase in the load index of systolic, diastolic and mean arterial pressure. Also, comorbid patients demonstrated higher blood pressure in contrast to the patients of the comparison group. They had increased systolic, diastolic and mean blood pressure variability and a quicker rate of morning blood pressure rise. According to 24-hour blood pressure dynamics, pathological types of the 24-hour blood pressure curve, a higher frequency of the night-peaker profile dominated in patients with COPD if compared to patients with HT. Conclusion. The obtained data indicated a high risk of cardiovascular complications in comorbid patients, early target organ damage and an unfavorable disease prognosis. It means that both further study of hypertension clinical course in such patients and personalization of antihypertensive therapy are relevant. Keywords: hypertension, chronic obstructive pulmonary disease, 24-hour monitoring, blood pressure. Пациенты с артериальной гипертензией (АГ) и хронической обструктивной болезнью легких (ХОБЛ) имеют высокий риск возникновения кардиоваскулярных осложнений. В настоящее время в лечении не определена наиболее оптимальная стратегия комбинированной антигипертензивной терапии. Для выбора тактики терапии важную роль играют показатели суточного мониторирования артериального давления (СМАД). Цель. Изучить особенности показателей СМАД у пациентов с АГ на фоне ХОБЛ. Материалы и методы. В исследование включено 130 пациентов с АГ. В основную группу (n=90) вошли пациенты с АГ и ХОБЛ (средний возраст – 61,30±1,01 года), в группу сравнения (n=40) – больные только АГ (средний возраст – 59,10±1,53 года). Всем пациентам проведено СМАД. Результаты. У пациентов с коморбидностью выявлены следующие особенности суточных показателей артериального давления: увеличение значений среднесуточных и средненочных показателей систолического и среднего артериального давления; существенное повышение индекса нагрузки систолическим, диастолическим и средним артериальным давлением. Также эти больные отличались от пациентов группы сравнения более высокими значениями пульсового давления, имели повышенную вариабельность систолического, диастолического и среднего артериального давления, у них наблюдалось увеличение скорости утреннего подъема артериального давления. Суточная динамика артериального давления у пациентов с ХОБЛ характеризовалась преобладанием патологических типов суточной кривой АД, более высокой частотой профиля night-peaker по сравнению с больными только АГ. Выводы. Выявленные особенности свидетельствуют о высоком риске сердечно-сосудистых осложнений у пациентов с коморбидностью, раннем поражении органов-мишеней и неблагоприятном прогнозе заболевания, что требует дальнейшего изучения особенностей клинического течения АГ у таких больных и индивидуализации антигипертензивной терапии. Ключевые слова: артериальная гипертензия, хроническая обструктивная болезнь легких, суточное мониторирование, артериальное давление.


2015 ◽  
Vol 309 (10) ◽  
pp. R1273-R1284 ◽  
Author(s):  
Jennifer Magnusson ◽  
Kevin J. Cummings

The role of serotonin (5-HT) neurons in cardiovascular responses to acute intermittent hypoxia (AIH) has not been studied in the neonatal period. We hypothesized that a partial loss of 5-HT neurons would reduce arterial blood pressure (BP) at rest, increase the fall in BP during hypoxia, and reduce the long-term facilitation of breathing (vLTF) and BP following AIH. We exposed 2-wk-old, 5,7-dihydroxytryptamine-treated and controls to AIH (10% O2; n = 13 control, 14 treated), acute intermittent hypercapnia (5% CO2; n = 12 and 11), or acute intermittent hypercapnic hypoxia (AIHH; 10% O2, 5% CO2; n = 15 and 17). We gave five 5-min challenges of AIH and acute intermittent hypercapnia, and twenty ∼20-s challenges of AIHH to mimic sleep apnea. Systolic BP (sBP), diastolic BP, mean arterial pressure, heart rate (HR), ventilation (V̇e), and metabolic rate (V̇o2) were continuously monitored. 5,7-Dihydroxytryptamine induced an ∼35% loss of 5-HT neurons from the medullary raphe. Compared with controls, pups deficient in 5-HT neurons had reduced resting sBP (∼6 mmHg), mean arterial pressure (∼5 mmHg), and HR (56 beats/min), and experienced a reduced drop in BP during hypoxia. AIHH induced vLTF in both groups, reflected in increased V̇e and V̇e/V̇o2, and decreased arterial Pco2. The sBP of pups deficient in 5-HT neurons, but not controls, was increased 1 h following AIHH. Our data suggest that a relatively small loss of 5-HT neurons compromises resting BP and HR, but has no influence on ventilatory plasticity induced by AIHH. AIHH may be useful for reversing cardiorespiratory defects related to partial 5-HT system dysfunction.


1998 ◽  
Vol 94 (1) ◽  
pp. 49-55 ◽  
Author(s):  
Sharmini Puvi-Rajasingham ◽  
Gareth D. P. Smith ◽  
Adeola Akinola ◽  
Christopher J. Mathias

1. In human sympathetic denervation due to primary autonomic failure, food and exercise in combination may produce a cumulative blood pressure lowering effect due to simultaneous splanchnic and skeletal muscle dilatation unopposed by corrective cardiovascular reflexes. We studied 12 patients with autonomic failure during and after 9 min of supine exercise, when fasted and after a liquid meal. Standing blood pressure was also measured before and after exercise. 2. When fasted, blood pressure fell during exercise from 162 ± 7/92 ± 4 to 129 ± 9/70 ± 5 mmHg (mean arterial pressure by 22 ± 5%), P < 0.0005. After the meal, blood pressure fell from 159 ± 8/88 ± 6 to 129 ± 6/70 ± 4 mmHg (mean arterial pressure by 22 ± 3%), P < 0.0001, and further during exercise to 123 ± 6/61 ± 3 mmHg (mean arterial pressure by 9 ± 3%), P < 0.01. The stroke distance—heart rate product, an index of cardiac output, did not change after the meal. During exercise, changes in the stroke distance—heart rate product were greater when fasted. 3. Resting forearm and calf vascular resistance were higher when fasted. Calf vascular resistance fell further after exercise when fasted. Resting superior mesenteric artery vascular resistance was lower when fed; 0.19 ± 0.02 compared with 032 ± 0.06, P < 0.05. After exercise, superior mesenteric artery vascular resistance had risen by 82%, to 0.53 ± 0.12, P < 0.05 (fasted) and by 47%, to 0.29 ± 0.05, P < 0.05 (fed). 4. On standing, absolute levels of blood pressure were higher when fasted [83 ± 7/52 ± 7 compared with 71 ± 2/41 ± 3 (fed), each P < 0.05]. Subjects were more symptomatic on standing post-exercise when fed. 5. In human sympathetic denervation, exercise in the fed state lowered blood pressure further than when fasted and worsened symptoms of postural hypotension.


2021 ◽  
pp. 1-8
Author(s):  
Yi-Tse Hsiao ◽  
Yun-Wen Peng ◽  
Pin Huan Yu

Monitoring blood pressure helps a clinical veterinarian assess various conditions in birds. Blood pressure is not only a bio-indicator of renal or cardiovascular disease but is also a vital indicator for anesthesia. Anesthetic- and sedation-related mortality is higher in birds than dogs or cats. The traditional method of blood pressure measurement in mammals mainly relies on indirect methods. However, indirect blood pressure measurement is not reliable in birds, making the direct method the only gold standard. Although an arterial catheter can provide continuous real-time arterial pressure in birds, the method requires technical skill and is limited by bird size, and is thus not practical in birds with circulatory collapse. Intra-osseous (IO) blood pressure is potentially related to arterial pressure and may be a much easier and safer technique that is less limited by animal size. However, the relationship between IO pressure and arterial blood pressure has not been established. This study used mathematical methods to determine the relationship between IO pressure and arterial blood pressure. The Granger causality (G.C.) theory was applied in the study and used to analyze which pressure signal was leading the other. Our findings suggest that IO pressure is G.C. by arterial blood pressure; thus, the use of IO pressure measurements as an alternative to arterial blood pressure measurement is a rational approach.


2002 ◽  
Vol 93 (6) ◽  
pp. 1966-1972 ◽  
Author(s):  
Maria T. E. Hopman ◽  
Jan T. Groothuis ◽  
Marcel Flendrie ◽  
Karin H. L. Gerrits ◽  
Sibrand Houtman

The purpose of the present study was to determine the effect of a spinal cord injury (SCI) on resting vascular resistance in paralyzed legs in humans. To accomplish this goal, we measured blood pressure and resting flow above and below the lesion (by using venous occlusion plethysmography) in 11 patients with SCI and in 10 healthy controls (C). Relative vascular resistance was calculated as mean arterial pressure in millimeters of mercury divided by the arterial blood flow in milliliters per minute per 100 milliliters of tissue. Arterial blood flow in the sympathetically deprived and paralyzed legs of SCI was significantly lower than leg blood flow in C. Because mean arterial pressure showed no differences between both groups, leg vascular resistance in SCI was significantly higher than in C. Within the SCI group, arterial blood flow was significantly higher and vascular resistance significantly lower in the arms than in the legs. To distinguish between the effect of loss of central neural control vs. deconditioning, a group of nine SCI patients was trained for 6 wk and showed a 30% increase in leg blood flow with unchanged blood pressure levels, indicating a marked reduction in vascular resistance. In conclusion, vascular resistance is increased in the paralyzed legs of individuals with SCI and is reversible by training.


Author(s):  
Sidharth Sraban Routray ◽  
Ramakanta Mohanty

ABSTRACTObjective: During laparoscopic surgeries, pneumoperitoneum can lead to various pathophysiologic changes in the cardiovascular system resulting inhypertension and tachycardia. Search for ideal drug to prevent this hemodynamic response goes on. The aim of our study was to evaluate the effect oforally administered moxonidine in attenuating the hemodynamic responses that occur during the laparoscopic surgeries.Methods: A total of 50 adult acetylsalicylic acid I and II patients scheduled for elective laparoscopic surgeries were selected for this prospectiverandomized double-blinded study. They were randomly allocated into two groups: moxonidine group (M) and placebo group (P). M group receivedoral moxonidine 0.3 mg at 8 pm on the day before surgery and at 8 am on the day of surgery. P group received a placebo at the same timing as that ofthe M group.Results: Following pneumoperitoneum rise in systolic blood pressure (SBP), diastolic BP (DBP), mean arterial pressure (MAP), and heart rate (HR)was higher in P group in comparison to M group which was statistically significant.Conclusion: Significant rise in HR, SBP, DBP, and mean BP was noted in the P group in comparison to moxonidine group. Moxonidine provided betterperioperative hemodynamic stability in patients undergoing laparoscopic surgeries.Keywords: Moxonidine, Stress response, Laparoscopic.


2019 ◽  
Vol 201 ◽  
pp. 06003
Author(s):  
Łukasz Stala ◽  
Krzysztof Tomczuk

The paper presents two methods of determining calibration curve of a new device for blood pressure measurement. The device was developed at Wrocław University of Science and Technology. First method is based on parallel measurement of systolic and diastolic pressure measurement with use of reference device such as sphygmomanometer and researched new device with pneumatic sensor equipped with voltage type output. Obtained data (systolic ps and diastolic pd pressure, maximum us and minimum ud voltage) was then used to determine individual pressure-voltage characteristic of the device, which can be represented as a linear equation. Second method is based on substitution of experimentally proved coefficient b with its analytical equivalent extracted from mathematical model of described pneumatic sensor. Described methods were verified experimentally and compared. Metrological parameters of the device were designated.