Can multiphase dynamic CT angiography provide a better assessment of aortic dissection compared with the standard triphasic protocol?

2017 ◽  
Vol 59 (1) ◽  
pp. 58-64 ◽  
Author(s):  
Chun-yan Lu ◽  
Yi-ke Diao ◽  
Ying-qiang Guo ◽  
Xiao-hui Zhang ◽  
Hong-li Bai ◽  
...  

Background Acute aortic dissection (AD) is a life-threatening medical emergency. It has been debated whether the multiphase dynamic computed tomography angiography (CTA) protocol is superior to the standard triphasic protocol for revealing the characteristics of AD. Purpose To examine two multiphase dynamic protocols, Dynamic four-dimensional (4D) CTA using the shuttle mode and Flash 4D CTA using the high-pitch mode for the assessment of AD and to compare them with the standard triphasic protocol. Material and Methods A total of 54 consecutive patients were randomly and equally assigned to three groups and scanned with a second-generation DSCT scanner. Groups A, B, and C were assessed with the Dynamic 4D CTA in the shuttle mode, the Flash 4D CTA in the high-pitch mode, and the standard triphasic acquisition protocol, respectively. Image quality of all patients was evaluated. The effective radiation dose (ED) was recorded. Results In 54 patients, CTA images could display the true and false lumens, the intimal flap, the entry tear, and branch vessel involvement in the AD. Compared with group C, additional diagnostic information was obtained in groups A and B, including the dynamic enhancement delay between the true and false lumens (A = 18, B = 18); the presence of membrane oscillation (A = 8, B = 14); dynamic ejection of the contrast material from the true lumen into the false lumen (A = 6, B = 7); and the dynamic obstruction of the left renal artery (B = 2). The ED in these three groups was significantly different ( P < 0.05). Conclusion Compared to the standard triphasic protocol, the multiphase dynamic CTA protocol is feasible and is able to reveal additional diagnostic information. Therefore, we recommend using the high-pitch, dual-source multiphase dynamic CTA to assess ADs.

2005 ◽  
Vol 44 (01) ◽  
pp. 8-14 ◽  
Author(s):  
B. Dietl ◽  
J. Marienhagen

Summary Aims: An explorative analysis of the diagnostic as well as therapeutic impact of 18F-FDG whole body PET on patients with various tumours in the setting of an university hospital radiation therapy was performed. Patients and methods: 222 FDG PET investigations (148 initial stagings, 74 restagings) in 176 patients with diverse tumour entities (37 lung carcinoma, 15 gastrointestinal tumours, 38 head and neck cancer, 30 lymphoma, 37 breast cancer, 19 sarcoma and 16 other carcinomas) were done. All PET scans were evaluated in an interdisciplinary approach and consecutively confirmed by other imaging modalities or biopsy. Unconfirmed PET findings were ignored. Proportions of verified PET findings, additional diagnostic information (diagnostic impact) and changes of the therapeutic concept intended and documented before PET with special emphasis on radiooncological decisions (therapeutic impact) were analysed. Results: 195/222 (88%) FDG-PET findings were verified, 104/222 (47%) FDG-PET scans yielded additional diagnostic information (38 distant, 30 additional metastasis, 11 local recurrencies, 10 primary tumours and 15 residual tumours after chemoptherapy). The results of 75/222 (34%) scans induced changes in cancer therapy and those of 58/222 (26%) scans induced modifications of radiotherapeutic treatment plan (esp. target volumes). Conclusion: 18F-FDG whole body PET is a valuable diagnostic tool for therapy planning in radiooncology with a high impact on therapeutic decisions in initial staging as well as in restaging. Especially in a curative setting it should be used for definition of target volumes.


2015 ◽  
Vol 18 (5) ◽  
pp. 208
Author(s):  
Erhan Kaya ◽  
Hakan Fotbolcu ◽  
Zeki Şimşek ◽  
Ömer Işık

We report a 61-year-old patient who suffered from a type A aortic dissection that mimicked an acute inferior myocardial infarction. During a routine cardiac catheterization procedure, diagnostic catheters can be inserted accidentally into the false lumen. Invasive cardiologists should keep this complication in mind.


2011 ◽  
Vol 14 (6) ◽  
pp. 373 ◽  
Author(s):  
Saina Attaran ◽  
Maria Safar ◽  
Hesham Zayed Saleh ◽  
Mark Field ◽  
Manoj Kuduvalli ◽  
...  

<p>Management of acute Stanford type A aortic dissection remains a major surgical challenge. Directly cannulating the ascending aorta provides a rapid establishment of cardiopulmonary bypass but consists of risks such as complete rupture of the aorta, false lumen cannulation, subsequent malperfusion and propagation of the dissection.</p><p>We describe a technique of cannulating the ascending aorta in patients with acute aortic dissection that can be performed rapidly in hemodynamically unstable patients under ultrasound-epiaortic and transesophageal (TEE) guidance.</p>


2020 ◽  
Vol 04 (05) ◽  
Author(s):  
Hervé Rousseau ◽  
Paul Revel-Mouroz ◽  
Charline Zadro ◽  
Camille Dambrin ◽  
Christophe Cron ◽  
...  

2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Mohammad Amin Abazari ◽  
Deniz Rafieianzab ◽  
M. Soltani ◽  
Mona Alimohammadi

AbstractAortic dissection (AD) is one of the fatal and complex conditions. Since there is a lack of a specific treatment guideline for type-B AD, a better understanding of patient-specific hemodynamics and therapy outcomes can potentially control the progression of the disease and aid in the clinical decision-making process. In this work, a patient-specific geometry of type-B AD is reconstructed from computed tomography images, and a numerical simulation using personalised computational fluid dynamics (CFD) with three-element Windkessel model boundary condition at each outlet is implemented. According to the physiological response of beta-blockers to the reduction of left ventricular contractions, three case studies with different heart rates are created. Several hemodynamic features, including time-averaged wall shear stress (TAWSS), highly oscillatory, low magnitude shear (HOLMES), and flow pattern are investigated and compared between each case. Results show that decreasing TAWSS, which is caused by the reduction of the velocity gradient, prevents vessel wall at entry tear from rupture. Additionally, with the increase in HOLMES value at distal false lumen, calcification and plaque formation in the moderate and regular-heart rate cases are successfully controlled. This work demonstrates how CFD methods with non-invasive hemodynamic metrics can be developed to predict the hemodynamic changes before medication or other invasive operations. These consequences can be a powerful framework for clinicians and surgical communities to improve their diagnostic and pre-procedural planning.


2021 ◽  
pp. 152660282199672
Author(s):  
Ahmed Eleshra ◽  
Fiona Rohlffs ◽  
Konstantinos Spanos ◽  
Giuseppe Panuccio ◽  
Franziska Heidemann ◽  
...  

Purpose: To report a single-center experience with the use of a custom-made Candy-Plug (CP) for distal false-lumen (FL) occlusion in subacute and chronic aortic dissection (AD). Materials and Methods: A retrospective single-center analysis was conducted on consecutive patients with subacute and chronic AD who were treated with a custom-made CP for distal FL occlusion using 3 design generations (CP I to CP III) from October 2013 to September 2019. Results: A custom-made CP was used in 57 patients. Of these, 34 patients (29 males, mean age 62±10 years) were treated with a CP I vs 23 patients (16 males, mean age 59±17 years) with CP II/III. Technical success was achieved in 57 (100%) patients. Clinical success was achieved in 54 (95%) patients; 33 (97%) in CP I group vs 21 (91%) patients in CP II/III group, p=0.116. The mean hospital stay was 10±8 days (9±5 days in CP I group vs 13±9 days in CP II/III, p=0.102). The 30-day computed tomography angiography (CTA) confirmed successful CP placement at the intended level in all patients within both groups. Early complete FL occlusion was achieved in 50 (88%) patients; 30 (88%) patients in CP I group vs 20 (87%) in CP II/III group, p=0.894. Follow up CTA was available in 44 (77%) patients. Of these; 30/34 (88%) patients in CP I group with mean follow-up 29±17 months) vs. 14/23 (61%) patients with mean follow-up 14±5 months in CP II/III group. Thoracic aortic remodeling was achieved in 34/44 (77%) patients; 25/30 (83%) patients in CP I group vs 9/14 (64%) patients in CP II/III group, p=0.197. The aneurysm size remained stable in 9/44 (20%) patients; 5/30 (17%) patients in CP I group vs 4/14 (29%) patients in CP II/III group, p=0.741. The thoracic aneurysm increased size was seen in 1/44 (2%) patient. This patient was in CPII/III group. Conclusion: CP technique using custom-made devices is technically feasible with a low mortality and morbidity, and a high rate of aortic remodeling. Both, the original design (CP I) and newer designs with a self-closing central sleeve (CP II and CP III) showed similar excellent outcomes.


2021 ◽  
Vol 9 ◽  
pp. 2050313X2110211
Author(s):  
Roxana Carmen Geana ◽  
Platon Pavel ◽  
Reza Nayyerani ◽  
Iulia Kulcsar ◽  
Adrian Tulin ◽  
...  

Here, we describe a case of a 61-year-old male patient with acute type A aortic dissection involving the ascending aorta, aortic arch, descending aorta, and the abdominal aorta down to the iliac bifurcation with evidence of left common iliac artery occlusion. Computed tomography angiography revealed progressive dissection into the superior mesenteric artery and left renal artery with no clinical signs of mesenteric ischemia. Emergent ascending aortic reconstruction of the dissected aorta relieves the leg ischemia. On a postoperative day 9, the evolution was complicated by massive right hemothorax. Although the patient was hemodynamically stable after obtaining hemostasis, the patient developed paralytic ileus with a high elevated lactate level. Visceral malperfusion was not detected by exploratory laparotomy. Emergency abdominal aortic angiography revealed superior mesenteric artery intermittent occlusion, successfully treated by stenting implantation.


Surgery Today ◽  
2004 ◽  
Vol 34 (8) ◽  
Author(s):  
Yoshihiko Kurimoto ◽  
Kiyofumi Morishita ◽  
Nobuyoshi Kawaharada ◽  
Johji Fukada ◽  
Yasufumi Asai ◽  
...  

Sign in / Sign up

Export Citation Format