Diagnostic accuracy of point-of-care knee ultrasound for evaluation of meniscus and collateral ligaments pathology in comparison with MRI

2021 ◽  
pp. 028418512110582
Author(s):  
Ahmed Elshimy ◽  
Ahmed M Osman ◽  
Mohamed El Sayed Awad ◽  
Mohamed M Abdel Aziz

Background Although magnetic resonance imaging (MRI) is often the “gold standard” for diagnosing knee problems, it has many limitations. Therefore, ultrasonography has been suggested as an effective rapid alternative in many knee abnormalities, especially after injuries of the meniscus and collateral ligaments. Purpose To determine the diagnostic accuracy of point-of-care ultrasound (POCUS) in detecting injuries of the meniscus and collateral ligament compared to MRI. Material and Methods An observational cross-sectional blinded study was conducted of 60 patients with clinically suspicious meniscus and collateral ligament injuries who were planned for an arthroscopy and or operative procedure. These patients underwent both blinded POCUS and MRI of the knees before the intervention procedure and results of both imaging modalities were compared according to the operative and arthroscopic findings. Results The preoperative reliability of POCUS compared to MRI for the assessment of meniscus injuries was sensitivity (92.9% vs. 90.5%), specificity (88.9% vs. 83.3%), positive predictive value (PPV; 95.1% vs. 92.7%), negative predictive value (NPV; 84.2% vs. 79%), and overall accuracy (91.7% vs. 88.3%). However, for diagnosing collateral ligament injures, POCUS versus MRI assessed sensitivity (92.3% vs. 88.5%), specificity (100% vs. 97.1%), PPV (100% vs. 95.8%), NPV (94.4% vs. 91.7%), and overall accuracy (96.7% vs. 93.3%). Conclusion Ultrasonography is a useful screening tool for the initial diagnosis of meniscal and collateral ligament pathology compared to or even with potential advantages over MRI, especially when MRI is unavailable or contraindicated. As newly advanced portable ultrasonography becomes available, it could be considered as a point-of-injury diagnostic modality.

2020 ◽  
pp. emermed-2020-210125
Author(s):  
Svenja L Haak ◽  
Iris JE Renken ◽  
L Cara Jager ◽  
Heleen Lameijer ◽  
Brigitta (Britt) YM van der Kolk

BackgroundA promising modality for diagnosing pulmonary manifestations of COVID-19 in the emergency department (ED) is point-of-care ultrasound (POCUS) of the lungs. The currently used PCR as well as chest X-ray and CT scanning have important disadvantages. The aim of this study is to evaluate the diagnostic accuracy of POCUS in patients with suspected pulmonary manifestations of COVID-19 in the ED.MethodsThis prospective diagnostic accuracy study was conducted at the ED of our non-academic level 1 trauma centre (Isala, Zwolle, the Netherlands). Patients were enrolled between 14 April and 22 April 2020. Patients (aged ≥16 years) with suspected COVID-19 presenting to the ED underwent POCUS. All patients received current standard of care, including PCR (naso-oropharyngeal swab). Outcome of POCUS was compared with PCR or CT scan outcome to determine diagnostic accuracy. Diagnostic accuracy measures were calculated using 2×2 contingency tables.Results100 patients were eligible to participate in this study, data of 93 patients were analysed. 27 (29%) patients were found positive for COVID-19 by PCR or CT. POCUS had a sensitivity of 89% (95% CI 70% to 97%), specificity of 59% (95% CI 46% to 71%), negative predictive value of 93% (95% CI 79% to 98%) and positive predictive value of 47% (95% CI 33% to 61%). In a subgroup of patients without previous cardiopulmonary disease (n=37), POCUS had a sensitivity of 100% (95% CI 70% to 100%), specificity of 76% (95% CI 54% to 90%), negative predictive value of 100% (95% CI 79% to 100%) and positive predictive value of 67% (95% CI 41% to 86%).ConclusionPOCUS of the lungs could serve as a valuable, radiation-free tool for excluding pulmonary manifestations of COVID-19 in patients in the ED at the point of assessment, especially in patients without previous cardiopulmonary disease.Trial registrationDutch Trial Register, No: NTR8544.


2021 ◽  
Vol 28 (12) ◽  
pp. 1812-1816
Author(s):  
Ijaz Ur Rehman ◽  
Samreen Younas ◽  
Salman Amin ◽  
Usman Tariq ◽  
Tahmasub Faraz Tayyab ◽  
...  

Objective: To evaluate the accuracy of ultrasonography in diagnosis of infectious maxillofacial/swelling. Study Design: Simple Cross Sectional study. Setting: Outpatient Department of Oral and Maxillofacial Surgery Unit, Punjab Dental Hospital, Lahore. Period: February 2016 to August 2016. Material & Methods: Conducted on 100 patients. The patients were evaluated with the ultrasound diagnostic modality. The ultrasound interpretation of all the cases was done and best possible diagnosis was made and recorded regarding diagnosis of infectious maxillofacial swellings. The incisional biopsy of every patient was done for histopathology. All findings of ultrasound and histopathology were entered to a proforma. Results: The average age of the patients was 35.81±14.31 years. In this study, 63% patients were males and 37% were females. Out of 100 patients, 70(70%) patients had infectious swelling while 30(30%) did not have infectious swelling. The sensitivity of ultrasonography was calculated as 84.72%, specificity was 67.86%, positive predictive value was 87.14%, negative predictive value was 63.33% and diagnostic accuracy was noted as 80% taking histopathology as gold standard. Conclusion: It was concluded from results of this study that ultrasonography has enough diagnostic accuracy to diagnose infectious swellings of maxillofacial region.


2021 ◽  
Vol 7 (3) ◽  
pp. 233
Author(s):  
Philipp Foessleitner ◽  
Herbert Kiss ◽  
Julia Deinsberger ◽  
Julia Ott ◽  
Lorenz Zierhut ◽  
...  

Pregnant women have an increased risk of vulvovaginal candidosis. Recurrent candidosis is under debate as a contributor to preterm birth, and vertical transmission may cause diaper dermatitis and oral thrush in the newborn. Apart from cultural methods, the gold standard for diagnosing candidosis is Gram staining, which is time-consuming and requires laboratory facilities. The objective of this prospective study was to validate a point-of-care vaginal yeast detection assay (SavvyCheckÔ Vaginal Yeast Test) and to evaluate it in asymptomatic pregnant women. We enrolled 200 participants, 100 of whom had vulvovaginal candidosis according to Gram stain (study group) and 100 were healthy pregnant controls (control group). Of these, 22 participants (11%) had invalid test results. The point-of-care test of the remaining 85 and 93 study participants in the study and control groups, respectively, showed a sensitivity of 94.1%, specificity of 98.9%, positive predictive value of 90.3%, and negative predictive value of 99.4% when compared with Gram stain. In conclusion, we found a high correlation between the SavvyCheckÔ Vaginal Yeast Test and Gram-stained smears during pregnancy. This suggests a potential role of this point-of-care test as a screening tool for asymptomatic pregnant women in early gestation.


2019 ◽  
pp. jramc-2018-001132
Author(s):  
Pierre Perrier ◽  
J Leyral ◽  
O Thabouillot ◽  
D Papeix ◽  
G Comat ◽  
...  

IntroductionTo evaluate the usefulness of point-of-care ultrasound (POCUS) performed by young military medicine residents after short training in the diagnosis of medical emergencies.MethodsA prospective study was performed in the emergency department of a French army teaching hospital. Two young military medicine residents received ultrasound training focused on gall bladder, kidneys and lower limb veins. After clinical examination, they assigned a ‘clinicaldiagnostic probability’ (CP) on a visual analogue scale from 0 (definitely not diagnosis) to 10 (definitive diagnosis). The same student performed ultrasound examination and assigned an ‘ultrasounddiagnostic probability’ (UP) in the same way. The absolute difference between CP and UP was calculated. This result corresponded to the Ultrasound Diagnostic Index (UDI), which was positive if UP was closer to the final diagnosis than CP (POCUS improved the diagnostic accuracy), and negative conversely (POCUS decreased the diagnostic accuracy).ResultsForty-eight patients were included and 48 ultrasound examinations were performed. The present pathologies were found in 14 patients (29%). The mean UDI value was +3 (0–5). UDI was positive in 35 exams (73%), zero in 12 exams (25%) and negative in only one exam (2%).ConclusionPOCUS performed after clinical examination increases the diagnostic accuracy of young military medicine residents.


2021 ◽  
Vol 15 (6) ◽  
pp. 1679-1681
Author(s):  
Afaque Ali ◽  
Majid Shaikh ◽  
Ahsanullah . ◽  
Adeel Ahmed ◽  
Abid Ali Sahito ◽  
...  

Objective: To determine the diagnostic accuracy of High-resolution computed tomography (HRCT) chest in detection of covid-19 infection taking PCR as gold standard. Study Design: Cross-sectional study Setting: Radiology department of Tabba Hospital, Karachi. Duration: From March 2019 to September 2020 Material and Methods: All the clinically suspected patients of covid-19, of any age, both genders and those referred to radiology for High-resolution computed tomography (HRCT) chest to detect the covid-19 infection were included. After two days, patients’ PCR reports were collected from the ward, after taking informed consent and permission from head of department. The diagnostic accuracy of HRCT was established with respect to sensitivity, PPV, NPV, and specificity by taking PCR as gold standard. All the information was collected via study proforma. Results: Total 70 patients suspected for COVID-19 were studied, and the patients’ mean age was 58.23±9.52 years. Males were in majority 54(77.1%). As per HRCT findings, COVID-19 infection was positive in 46 patients, however, 48 patients were detected positive for COVID-19 infection as per PCR findings. In the detection of COVID-19 infection, HRCT chest showed sensitivity of 91%, specificity of 90%, PPV of 83%, NPV of 84% and diagnostic accuracy of 94%; by taking PCR as gold standard. Conclusion: High-resolution computed tomography (HRCT) is a reliable diagnostic approach in promptly detecting the COVID-19; with 91% sensitivity, 90% specificity, 83% positive predictive value, 84% negative predictive value and 94% diagnostic accuracy. Keywords: Accuracy, HRCT, COVID-19


Diagnostics ◽  
2020 ◽  
Vol 10 (12) ◽  
pp. 1011
Author(s):  
Sofia Nevander ◽  
Eva Landberg ◽  
Marie Blomberg ◽  
Bertil Ekman ◽  
Caroline Lilliecreutz

Gestational diabetes mellitus (GDM) is a common complication with negative impacts on mother and child. The primary aim of this study was to examine whether plasma glucose cutoffs for GDM diagnosis based on venous sampling can be replaced by cutoffs based on capillary sampling. A prospective cross-sectional study was performed at an antenatal care clinic including 175 pregnant women undergoing an oral glucose tolerance test (OGTT). Duplicate samples were collected by capillary and venous puncture while fasting and 1 h and 2 h after an OGTT. Both samples were analyzed on Accu-Chek Inform II. The cutoffs for a GDM diagnosis using capillary samples were corrected from 5.1 to 5.3 mmol/L for the fasting sample, from 10.0 to 11.1 mmol/L for the 1 h sample, and from 8.5 to 9.4 mmol/L for the 2-h sample using half of the dataset. Applying these cutoffs to the remaining dataset resulted in a sensitivity, specificity, and accuracy of 85.0%, 95.0%, and 90.3%, respectively, with a positive predictive value (PPV) of 83%, an negative predictive value (NPV) of 96%, and a positive negative likelihood ratio (LHR) of 16.4 using capillary sampling for the GDM diagnosis at fasting and 2-h after. Corrected cutoffs and capillary samples can be used for the diagnosis of GDM with maintained diagnostic accuracy using Accu-Chek Inform II.


2012 ◽  
Vol 20 (01) ◽  
pp. 132-138
Author(s):  
MUHAMMAD ATIF ◽  
MUHAMMAD ABDULLAH ◽  
MUHAMMAD JAVAD YOUSAF ◽  
Khalid Buland

Objective: To compare the accuracy of Upper lip bite test with modified Mallampati classification for predicting the difficultlaryngoscopic intubation. Study Design: Cross sectional Study. Place and duration of study: The study was carried out at Department ofAnaesthesiology, Intensive Care and Pain management, Combined Military hospital, Rawalpindi from September 2008 to August 2009.Patients and Methods: Four hundred patients undergoing elective surgery meeting the inclusion/exclusion criteria were enrolled afterwritten informed consent. The airways of the patients were evaluated by using the modified Mallampati classification (MMP) and theUpper lip bite test (ULBT). MMP class 3 or 4 and ULBT class 3 were considered as indicators of difficult intubation. The laryngeal view wasgraded by Cormack and Lehane classification (Gold standard). Grade 1 or 2 was considered to represent easy intubation and grade 3 or 4to represent difficult intubation. Sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy werecalculated for both the tests separately by using the 2×2 table. Results: ULBT had a higher accuracy of 94%, specificity of 99.2% andpositive predictive value 70% compared to MMP accuracy of 82.7%, specificity of 84.4% and positive predictive value of 22.7%.Conclusions: The diagnostic accuracy of the Upper lip bite test was more than the modified Mallampati classification. We suggest that itbe compared with the other prevailing tests as well which are often used to assess difficult intubations.


Circulation ◽  
2020 ◽  
Vol 142 (Suppl_3) ◽  
Author(s):  
Libo Wang ◽  
Jonathan Harrison ◽  
Elizabeth Dranow ◽  
Lillian Khor

Introduction: Accurate intravascular volume status assessment is central to heart failure management, but current non-invasive bedside techniques remain a challenge. The visual inspection of jugular venous pulsation (JVP) in a reclined position and measuring its height from the sternal notch has been used as a surrogate for right atrial pressure (RAP). There are no studies on the predictive value of a visible internal jugular vein (IJV) in the upright position (U 2 JVP). Hypothesis: Point of care ultrasound (POCUS) for volume assessment in the upright position is predictive of clinically significant hypervolemia. Methods: Adult patients undergoing right heart catheterization (RHC) were enrolled prior for IJV imaging with point of care ultrasound (POCUS) device, Butterfly iQ™. The IJV and its size in comparison to the carotid artery was identified on ultrasound with the patient upright. Elevated RAP and PCWP was present if the IJV was still visible and not collapsed throughout the entirety of the respiratory cycle. Valsalva was used to confirm the position of a collapsed IJV. Results: 72 participants underwent U 2 JVP assessment on the same day prior to RHC. Average BMI was 31.9 kg/m2. The area under the curve (AUC) of U 2 JVP predicting RAP greater than 10 mmHg and PCWP of 15 mmhg or higher on RHC was 0.78 (95% CI 0.66-0.9, p<0.001), with AUC of 0.86 and 0.74 for non-obese and obese subgroups respectively, p= 0.38. The finding of a visible U 2 JVP in the upright position was 70.6 % sensitive and 85.5 % specific with a negative predictive value of 90.4% for identifying both RAP greater than 10 mmHg and PCWP equal or greater than 15 mmHg. Conclusions: The U 2 JVP is novel and pragmatic bed-side approach to the assessment of clinically significant elevated intra-cardiac pressures in our increasingly obese heart failure population.


Sign in / Sign up

Export Citation Format

Share Document