193 nm
Recently Published Documents


TOTAL DOCUMENTS

2012
(FIVE YEARS 67)

H-INDEX

59
(FIVE YEARS 4)

PLoS ONE ◽  
2021 ◽  
Vol 16 (11) ◽  
pp. e0260494
Author(s):  
Ibrahim Abdelhalim ◽  
Omnia Hamdy ◽  
Aziza Ahmed Hassan ◽  
Salah Hassab Elnaby

Corneal reshaping is a common medical procedure utilized for the correction of different vision disorders relying on the ablation effect of the UV pulsed lasers, especially excimer lasers (ArF) at 193 nm. This wavelength is preferred in such medical procedures since laser radiation at 193 nm exhibits an optimum absorption by corneal tissue. However, it is also significantly absorbed by the water content of the cornea resulting in an unpredictability in the clinical results, as well as the high service and operation cost of the commercial ArF excimer laser device. Consequently, other types of solid-state UV pulsed lasers have been introduced. The present work investigates the ablation effect of solid-state laser at 266 nm in order to be utilized in corneal reshaping procedures. Different number of pulses has been applied to Polymethyl Methacrylate (PMMA) and ex-vivo rabbit cornea to evaluate the ablation effect of the produced laser radiation. PMMA target experienced ellipse-like ablated areas with a conical shape in the depth. The results revealed an almost constant ablation area regardless the number of laser pulses, which indicates the stability of the produced laser beam, whereas the ablation depth increases only with increasing the number of laser pulses. Examination of the ex-vivo cornea showed a significant tissue undulation, minimal thermal damage, and relatively smooth ablation surfaces. Accordingly, the obtained 266-nm laser specifications provide promising alternative to the traditional 193-nm excimer laser in corneal reshaping procedure.


2021 ◽  
Author(s):  
Gyo Wun Kim ◽  
Won Jun Chang ◽  
Ji Eun Kang ◽  
Hee Ju Kim ◽  
Geun Young Yeom

Abstract Even though EUV lithography has the advantage of implenting a finer pattern compared to ArF immersion lithography due to the use of 13.5 nm instead of 193 nm as the wavelengh of the light source, due to the low energy of EUV light source, EUV resist has a thinner thickness than conventional ArF resist. EUV resist having such a thin thickness is more vulnerable to radiation damage received during the etching because of its low etch resistance and also tends to have a problem of low etch selectivity. In this study, the radiation damage to EUV resist during etching of hardmask materials such as Si3N4, SiO2, etc. using CF4 gas was compared between neutral beam etching (NBE) and ion beam etching (IBE). When NBE was used, after the etching of 20 nm thick EUV resist, the line edge roughness (LER) increase and the critical dimension (CD) change of EUV resist were reduced by ~ 1/3 and ~ 1/2, respectively, compared to those by IBE. Also, at that EUV etch depth, the RMS(root mean square) surface roughness value of EUV resist etched by NBE was ~2/3 compared to that by IBE on the average. It was also confirmed that the etching selectivity between SiO2, Si3N4, etc. and EUV resist was higher for NBE compared to IBE. The less damage to the EUV resist and the higher etch selectivity of materials such as Si3N4 and SiO2 over EUV resist for NBE compared to IBE are believed to be related to the no potential energy released by the neutralization of the ions during the etching for NBE.


Analytica ◽  
2021 ◽  
Vol 2 (4) ◽  
pp. 140-155
Author(s):  
Mowei Zhou ◽  
Ju Yeon Lee ◽  
Gun Wook Park ◽  
Neha Malhan ◽  
Tao Liu ◽  
...  

Despite the successful application of tandem mass tags (TMT) for peptide quantitation, missing reporter ions in higher energy collisional dissociation (HCD) spectra remains a challenge for consistent quantitation, especially for peptides with labile post-translational modifications. Ultraviolet photodissociation (UVPD) is an alternative ion activation method shown to provide superior coverage for sequencing of peptides and intact proteins. Here, we optimized and evaluated 193 nm UVPD for the characterization of TMT-labeled model peptides, HeLa proteome, and N-glycopeptides from model proteins. UVPD yielded the same TMT reporter ions as HCD, at m/z 126–131. Additionally, UVPD produced a wide range of fragments that yielded more complete characterization of glycopeptides and less frequent missing TMT reporter ion channels, whereas HCD yielded a strong tradeoff between characterization and quantitation of TMT-labeled glycopeptides. However, the lower fragmentation efficiency of UVPD yielded fewer peptide identifications than HCD. Overall, 193 nm UVPD is a valuable tool that provides an alternative to HCD for the quantitation of large and highly modified peptides with labile PTMs. Continued development of instrumentation specific to UVPD will yield greater fragmentation efficiency and fulfil the potential of UVPD to be an all-in-one spectrum ion activation method for broad use in the field of proteomics.


Molecules ◽  
2021 ◽  
Vol 26 (18) ◽  
pp. 5571
Author(s):  
Piotr Rytlewski ◽  
Bartłomiej Jagodziński ◽  
Rafał Malinowski ◽  
Bogusław Budner ◽  
Krzysztof Moraczewski ◽  
...  

Polyurethane coatings containing copper(II) L-tyrosine and glass microspheres were laser irradiated and underwent electroless metallization. Various sizes of glass microspheres were incorporated into the polyurethane coating matrix in order to examine their effects on surface activation and electroless metallization. The surface of the coatings was activated by using ArF excimer laser emitting ultraviolet radiation (λ = 193 nm) using different number of laser pulses and their fluence. The effects of surface activation and metallization were evaluated mainly based on optical and scanning electron microcopies (SEM), energy-dispersive X-ray spectroscopy (EDX) and photoelectron spectroscopy (XPS). It was found that the presence of glass microspheres enabled the reduction in copper complex content, intensified the ablation process (higher cone-like structures created) and resulted in higher content of copper metallic seeds. On the other hand, the glass microspheres concentration, which was higher for lower size microspheres, was advantageous for obtaining a fully metallized layer.


2021 ◽  
Vol 22 (16) ◽  
pp. 8436
Author(s):  
Konrad Szustakiewicz ◽  
Bartłomiej Kryszak ◽  
Paulina Dzienny ◽  
Błażej Poźniak ◽  
Marta Tikhomirov ◽  
...  

In this research we subjected samples of poly(L-lactide) (PLLA) extruded film to ultraviolet (193 nm ArF excimer laser) radiation below the ablation threshold. The modified film was immersed in Simulated Body Fluid (SBF) at 37 °C for 1 day or 7 days to obtain a layer of apatite ceramic (CaP) coating on the modified PLLA surface. The samples were characterized by means of optical profilometry, which indicated an increase in average roughness (Ra) from 25 nm for the unmodified PLLA to over 580 nm for irradiated PLLA incubated in SBF for 1 day. At the same time, the water contact angle decreased from 78° for neat PLLA to 35° for irradiated PLLA incubated in SBF, which suggests its higher hydrophilicity. The obtained materials were investigated by means of cell response fibroblasts (3T3) and macrophage-like cells (RAW 264.7). Properties of the obtained composites were compared to the unmodified PLLA film as well as to the UV-laser irradiated PLLA. The activation of the PLLA surface by laser irradiation led to a distinct increase in cytotoxicity, while the treatment with SBF and the deposition of apatite ceramic had only a limited preventive effect on this harmful impact and depended on the cell type. Fibroblasts were found to have good tolerance for the irradiated and ceramic-covered PLLA, but macrophages seem to interact with the substrate leading to the release of cytotoxic products.


Sign in / Sign up

Export Citation Format

Share Document