scholarly journals Analgesia following Arthroscopic Knee Surgery. A Controlled Study of Intra-articular Morphine, Bupivacaine or Both Combined

1993 ◽  
Vol 21 (2) ◽  
pp. 201-203 ◽  
Author(s):  
M. M. McSwiney ◽  
G. P. Joshi ◽  
P. Kenny ◽  
S. M. McCarroll

In a double-blind, randomised controlled trial, we studied 40 patients who received one of four intra-articular injections at the end of arthroscopic surgery. Each group contained ten patients. The patients in Group 1 received normal saline 25 ml; those in Group 2 received bupivacaine 0.25% 25 ml; those in Group 3 received morphine 5 mg in normal saline 25 ml; and those in Group 4 received a combination of bupivacaine 0.5% 12.5 ml and 5 mg of morphine made up to 25 ml with normal saline to produce the same bupivacaine concentration as Group 2. At the time the patient awoke, and 30min, Ihr, Ihr 30min, 2hr, 4hr, 8hr, 12hr, and 24hr postoperatively, pain was assessed using a visual analogue scale. The need for supplementary analgesic agents in the first 24 hours was recorded. All pain scores were significantly lower (P< 0.05) in Groups 2, 3 and 4 compared with the control group with the exception of Group 2 at 24 hours. Pain scores were significantly lower (P<0.05) for Group 2 compared with Group 3 for the first 90 minutes postoperatively. At 4, 8, 12 and 24 hours postoperatively the pain scores were significantly lower (P<0.05%) for Group 3 compared with Group 2. Group 4 had the lowest pain scores over the recorded period compared with the other groups. The need for supplemental analgesia was significantly lower (P<0.05) in the treatment Groups 2, 3 and 4 compared to the control Group 1. There was no significant difference in supplemental analgesic requirements between Groups 2, 3 and 4. A combination of bupivacaine and morphine injected intra-articularly following arthroscopy provided superior analgesia compared with that achieved by either drug alone.

2021 ◽  
Vol 14 (4) ◽  
pp. 1508-1513
Author(s):  
Ibraheem F Alshiddi

In order to assess the influence of finishing and polishing on the surface brightness and color stability of the ceramic veneer, fifty specimens were fabricated with 10 mm diameter and 2 mm thickness using IPS E-Max Ceramic. After glazing, 10 specimens were untouched as control group, and the other 40 specimens were abraded using 125µm diamond bur to create surface roughness. Forty specimens were divided into four groups (n=10), in group 1: specimens were finished using diamond point, in group 2 specimens’ surface was polished with a polishing kit, Group 3: Each specimen surface was polished with the polishing kit as in protocol 2 and was polished a polishing past and group 4 Each specimen was glazed by heating at 621℃ for 3 minutes followed by a temperature increase of 83℃/min up to 918℃ for 30 seconds. Color measurement was performed using spectrophotometer. Color stability data were analyzed using two-way ANOVA and Tukey’s HSD test (α=0.05). For Ra values, paired-samples t-tests were used to analyze the data and compare groups. The change in L and E showed a significant difference among the study groups; (group 1, group 2, group 3 and group 4) with respect to three variables L, a and b. A significant difference was noted when compared each group with the control; however, only group 2 showed a significant difference from group 4; the remaining groups demonstrated similar findings for all three variables. The study displayed a significant impact of the finishing and polishing technique on the surface brightness and color stability of ceramic restoration. However, it was evident that combination of two or three polishing techniques which includes polish kit and glaze enhances the surface finish and adds color stability by alternating the yellow – blue axis (increase in b) and red- green axis (decrease in a).


Author(s):  
Mine ARGALI DENIZ ◽  
Hilal ER ULUBABA ◽  
M. Furkan ARPACI ◽  
Fatih CAVUS ◽  
Gokhan DEMIRTAS ◽  
...  

Objective: In this study, the effect of tracheal diverticula (TD) on chest anthropometry and its relation with chronic obstructive pulmonary disease (COPD) was evaluated. Method: Between January 2019 and March 2020, 995 patients who underwent chest CT were retrospectively analyzed and TD was detected in 31 cases. Group 1 is only TD, Group 2 is TD + COPD, Group 3 is only COPD, Group 4 is defined as control group. We measured the localization, size, the distance to carina and vocal cord of TDs. In all groups chest diameters at T4 and T9 levels were measured as transverse and vertical plans. Results: TDs detected mostly at the T2 and T3 levels. In Group 1 and Group 2, there was a statistically significant difference the distance to TD of vocal chords. A statistically significant difference was found between Group 1 and Group 3 only in the vertical diameter at the T4 and T9 levels. Conclusion: We observed that COPD effect TD location and also TD had opposite effect on anteroposteriorly increasing chest parameters in COPD. Precence of TD is essential on COPD patients about thorax anthropometry. Keywords: Tracheal diverticulum; antropometry; radiology; COPD; chest diameter


2015 ◽  
Vol 20 (2) ◽  
pp. 107-111 ◽  
Author(s):  
Bekir Serdar Unlu ◽  
Mehmet Yilmazer ◽  
Gulengul Koken ◽  
Dagistan Tolga Arioz ◽  
Ebru Unlu ◽  
...  

BACKGROUND: Hysterosalpingography (HSG) is the most commonly used method for evaluating the anatomy and patency of the uterine cavity and fallopian tubes, and is an important tool in the evaluation of infertility. The most frequent side effect is the pain associated with the procedure.OBJECTIVES: To evaluate four analgesic methods to determine the most useful method for reducing discomfort associated with HSG.METHODS: In the present prospective study, 75 patients undergoing HSG for evaluation of infertility were randomly assigned to four groups: 550 mg of a nonsteroidal anti-inflammatory drug (NSAID) (group 1); 550 mg NSAID + paracervical block (group 2); 550 mg NSAID + paracervical analgesic cream (group 3); or 550 mg NSAID + intrauterine analgesic instillation (group 4). A visual analogue scale was used to assess the pain perception at five predefined steps.RESULTS: Instillation of the liquids used for HSG was found to be the most painful step of HSG, and this step was where the only significant difference among groups was observed. When comparing visual analogue scale scores, group 2 and group 3 reported significantly less pain than the other groups. Group 1 reported significantly higher mean ( ± SD) scores (7.2 ± 1.6) compared with groups 2 and 3 (4.7 ± 2.5 and 3.8 ± 2.4, respectively) (P<0.001). In addition, group 2 reported significantly less pain than group 4 (4.7 ± 2.5 versus 6.7 ± 1.8, respectively) (P<0.02).CONCLUSIONS: For effective pain relief during HSG, in addition to 550 mg NSAID, local application of lidocaine cream to the posterior fornix of the cervix uteri and paracervical lidocaine injection into the cervix uteri appear to be the most effective methods.


2015 ◽  
Vol 63 (4) ◽  
pp. 426-431
Author(s):  
Ariani Rodrigues DIMER ◽  
Guilherme Anziliero AROSSI ◽  
Leonardo Haerter dos SANTOS ◽  
Diego Rafael KAPPAUN

Objective: To evaluate the influence of different additional polymerization methods on the microhardness of two direct composite resins. Methods: Direct Composite resins samples (Fill Magic and Opallis) and a Laboratory Composite Resin (Ceramage) were lightcured according to manufacturer instructions. Then, the direct resins were submitted to additional polymerization. Experimental groups were divided into (n = 5): group 1: Conventional Polymerization; group 2: Extra Light (80s); group 3: Autoclave; group 4: Laboratory Resin Ceramage. Vickers hardness test was carried out after a week of light-free storage in water, and results were subjected to ANOVA / Tukey statistical analysis. Results: Resin Lab Ceramage showed higher astatistically significant microhardness within all other resins in this study (p £ 0.05); Fill Magic showed no statistically significant difference between the groups tested compared to its control (p> 0.05); Opallis resin submitted to autoclave was the only method that showed a higher statistically significant difference compared to the control group (p £ 0.05). Conclusion: It concludes that hardness of a direct composite resin tested - Opallis - was increased by Autoclave post-cure polymerization, however, not enough to achieve the hardness of a laboratory composite. Furthermore, increasing lightcuring time does not produce a harder surface.


2007 ◽  
Vol 77 (5) ◽  
pp. 901-906 ◽  
Author(s):  
Tamer Turk ◽  
Selma Elekdag-Turk ◽  
Devrim Isci ◽  
Fethiye Cakmak ◽  
Nurhat Ozkalayci

Abstract Objective: To evaluate shear bond strengths (SBSs) of a self-etching primer (SEP) following saliva contamination at different stages of bonding at debond times of 5, 15, and 30 minutes and 24 hours. Materials and Methods: Two-hundred forty human premolars were divided into four groups: group 1, uncontaminated; group 2, saliva contamination after priming; group 3, saliva contamination before priming; and group 4, saliva contamination before and after priming. Four subgroups according to debond times of 5, 15, 30 minutes and 24 hours were composed. Metal brackets were bonded with an SEP (Transbond Plus) and light-cure adhesives paste (Transbond XT). SBS values and the adhesive remnants were determined. Results: The highest SBS was obtained at a debond time of 24 hours for the control group. This was significantly different from the other groups. SBSs at 5, 15, and 30 minutes showed no significant difference from each other in the control group (P &gt; .05). Lowest SBSs were obtained at a debond time of 5 minutes for groups 1, 2, 3, and 4 (8.38, 7.10, 7.06, and 6.26 MPa, respectively) and were not significantly different from each other (P &gt; .05). SBSs at 24 hours were not significantly different from each other for groups 2, 3, and 4 (P &gt; .05). Significant differences were found in the adhesive remnant (P &lt; .001). Conclusions: SEP (Transbond Plus) may produce clinically acceptable bracket bonding after 5, 15, and 30 minutes from time of placement on the teeth, even with light and heavy saliva contamination.


Author(s):  
R Piradhiba ◽  
Evan A Clement ◽  
Navaneetha Nambi ◽  
S Veerasankar ◽  
S Madhumitra ◽  
...  

Introduction: Orthodontic elastics are a very significant tool in orthodontics, as it is the most commonly used force delivering unit. Temperature plays a key role in the amount of force that elastics are able to produce. Hence, there is a need to evaluate the influence of storage temperature on the properties of orthodontic elastics before its clinical use. Aim: To evaluate the influence of different storage temperature of latex orthodontic elastics. Materials and Methods: This cross-sectional study was conducted at Sathyabama Dental College and Hospital, Chennai, in November 2019. Sample of 40 latex orthodontic elastics (TP Orthodontics, medium force, standard size of 3/16′′) were divided into four groups with 10 elastics each, based on their storage temperature and stored in closed plastic packages. Group 1 was kept as a Control group and Group 2, Group 3 and Group 4 were stored in three Incubators under the specified storage temperatures such as 26-28°C, 4-8°C, 37°C respectively. The elastics were stretched and their forces measured in six progressive increases of 100% of their inner diameter, starting at a level of 100% stretching, with the Universal Testing Machine, Instron. The samples were also tested for Maximum Stress (MPa), Maximum Force (N), Maximum Elongation (%) and Break Distance (mm). Data were analysed using Statistical Package for the Social Science (SPSS) software version 16.0, one-way Analysis of Variance (ANOVA) and post-hoc test. Results: On evaluating the stress at 100%, 200%, 300%, 400%, 500%, 600% of strain, there was no statistically significant difference between the groups. Maximum Stress MPa was found to be 24.12±3.32, 25.12±3.42, 23.3±3.41, 23.97±3.50 for group1, group 2, group 3 and group 4 respectively. Maximum Elongation (%) was found to be 1369.0±25.108, 1364.0±23.190, 1359.0±35.103, 1363.0±34.657 for group 1, group 2, group 3 and group 4, respectively. Break Distance (mm) was found to be 68.48±1.267, 68.28±1.267, 67.87±1.77 and 68.19±1.727 for group1, group 2, group 3 and group 4, respectively. And none of the parameters tested showed statistical significance between the four groups. Conclusion: Latex elastics may be stored under any of the conditions tested in the present study over a period of one month, since different storage temperatures over a period of one month did not interfere in their mechanical properties.


VASA ◽  
2020 ◽  
Vol 49 (4) ◽  
pp. 281-284
Author(s):  
Atıf Yolgosteren ◽  
Gencehan Kumtepe ◽  
Melda Payaslioglu ◽  
Cuneyt Ozakin

Summary. Background: Prosthetic vascular graft infection (PVGI) is a complication with high mortality. Cyanoacrylate (CA) is an adhesive which has been used in a number of surgical procedures. In this in-vivo study, we aimed to evaluate the relationship between PVGI and CA. Materials and methods: Thirty-two rats were equally divided into four groups. Pouch was formed on back of rats until deep fascia. In group 1, vascular graft with polyethyleneterephthalate (PET) was placed into pouch. In group 2, MRSA strain with a density of 1 ml 0.5 MacFarland was injected into pouch. In group 3, 1 cm 2 vascular graft with PET piece was placed into pouch and MRSA strain with a density of 1 ml 0.5 MacFarland was injected. In group 4, 1 cm 2 vascular graft with PET piece impregnated with N-butyl cyanoacrylate-based adhesive was placed and MRSA strain with a density of 1 ml 0.5 MacFarland was injected. All rats were scarified in 96th hour, culture samples were taken where intervention was performed and were evaluated microbiologically. Bacteria reproducing in each group were numerically evaluated based on colony-forming unit (CFU/ml) and compared by taking their average. Results: MRSA reproduction of 0 CFU/ml in group 1, of 1410 CFU/ml in group 2, of 180 200 CFU/ml in group 3 and of 625 300 CFU/ml in group 4 was present. A statistically significant difference was present between group 1 and group 4 (p < 0.01), between group 2 and group 4 (p < 0.01), between group 3 and group 4 (p < 0.05). In terms of reproduction, no statistically significant difference was found in group 1, group 2, group 3 in themselves. Conclusions: We observed that the rate of infection increased in the cyanoacyrylate group where cyanoacrylate was used. We think that surgeon should be more careful in using CA in vascular surgery.


2012 ◽  
Vol 2012 ◽  
pp. 1-6 ◽  
Author(s):  
Lyudmil Terziev ◽  
Violeta Dancheva ◽  
Veneta Shopova ◽  
Galya Stavreva

Aim. To investigate the effects of MnTE-2-PyP on some markers of antioxidant defence system in asthma mice model.Material and Methods. The animals were divided into four groups: group 1, controls; group 2, injected with ovalbumin, group 3, treated with MnTE-2-PyP, and group 4, treated with ovalbumin and MnTE-2-PyP. The activities of superoxide dismutase, catalase, glutathione peroxidase and nonprotein sulfhydryl groups content (NPSH) were determined in lung homogenate.Results. The activities of superoxide dismutase and catalase in group 2 decreased significantly as compared to control group. The decrease of the same enzymes in group 4 was lower and significant as compared to group 2. Changes in the glutathione peroxidase activity showed a similar dynamics. The NPSH groups content decreased in group 2. In group 4 this decrease was relatively lower as compared to group 2.Conclusions. The application of MnTE-2-PyP mitigated the effects of oxidative stress in asthma mice model.


2018 ◽  
Vol 24 (1) ◽  
pp. 37
Author(s):  
Annisa Trissatharra ◽  
Sri Ratna Dwiningsih ◽  
Ratna Sofaria Munir

Objectives: To identify the effect of monoclonal antibody bZP3 at ovarian follicles that undergo atresia and diameter of various ovarian follicles.Materials and Methods: This is a true experimental research with post only control group design. Samples were 36 female mices (Mus musculus) which is divided into 6 groups, there are 3 control groups (group 1, 2, and 3) injected by Phospatase Buffer Saline (PBS) 50µl and 3 treatment groups (group 4, 5, and 6) injected by Mab bZP3 50µl. Group 1 and 4 terminated at 5th day, group 2 and 5 terminated at 10th day, and group 3 and 6 terminated at 20th day. Evaluation of atretic ovarian follicles and diameter of ovarian follicles performed by hematoxylin eosin (HE) and the data processed by parametric statistic.Results: There are no significant in different among groups in the aspect of atretic follicles and diameter of folicles (p>0.05), but descriptively, number of follicles undergo atresia of the follicle primary, secondary, and tertiary treatment group was higher than the control group, except on the 20th day of observation time.Conclusion: administration of Mab bZP3 had no effect to amount of atretic follicles and diameter of folicles during observation time.


2020 ◽  
Vol 11 (1) ◽  
pp. 280-284 ◽  
Author(s):  
Julietpoornamathy J ◽  
Parameswari C.S.

In medical sciences, toxicity is an area wherein extensive studies have been carried to improve the diseases as well as to prevent. So, there is a high requirement for novel and improved alternative therapeutic strategies to manage diseases. The liver is the largest gland in the body, which executes several important mechanisms; it stores minerals and vitamins and releases them in periods of need. The main aim of this study was to give a closer insight into potent non- toxic compounds that is capable of modifying the responses. Animals were divided into five equal groups viz control (Group 1), administered with food and water ad libitum, (Group 2) administered with olive oil, (Group 3) administered with zingerone, (Group 4) administered with concanavalin A, (Group 5) administered with cyclosporine A followed by zingerone. Our results revealed significant changes in liver marker enzymes and liver histology of zingerone treated rats when compared to control rats.  A corollary, zingerone has no toxic effect on hepatocytes and was found to be safe at a dose of 10mg/kg b wt and also ameliorates hepatotoxicity.


Sign in / Sign up

Export Citation Format

Share Document