The biomechanical study of cervical spine: A Finite Element Analysis

2021 ◽  
pp. 039139882199549
Author(s):  
Pechimuthu Susai Manickam ◽  
Sandipan Roy

The biomechanical study helps us to understand the mechanics of the human cervical spine. A three dimensional Finite Element (FE) model for C3 to C6 level was developed using computed tomography (CT) scan data to study the mechanical behaviour of the cervical spine. A moment of 1 Nm was applied at the top of C3 vertebral end plate and all degrees of freedom of bottom end plate of C6 were constrained. The physiological motion of the cervical spine was validated using published experimental and FE analysis results. The von Mises stress distribution across the intervertebral disc was calculated along with range of motion. It was observed that the predicted results of functional spine units using FE analysis replicate the real behaviour of the cervical spine.

2005 ◽  
Vol 09 (01) ◽  
pp. 1-7 ◽  
Author(s):  
Ee-Chon Teo ◽  
Qing-Hang Zhang ◽  
Hong-Wan Ng

A detailed three-dimensional head-neck (C0–C7) finite element (FE) model developed previously based on the actual geometry of a cadaveric specimen was used to characterize the whiplash phenomenon of the head-neck region during rear-end collision. A maximum rear impact pulse of 8.5 G of acceleration was applied to C7. The effects of a headrest on the responses of head-neck complex were also discussed. The study demonstrates the effectiveness of the current C0–C7 FE model in characterizing the gross responses of human cervical spine under whiplash. The results showed that during whiplash, the lower cervical levels, especially the C6–C7, experience hyperextension in the early phase of acceleration. The whole cervical spine is at risk of extension injuries rather than flexion injuries in whiplash. The use of a proper headrest can effectively reduce the cervical spine from extension injury during the acceleration phase of cervical spine in whiplash.


Author(s):  
Nurullah Türker ◽  
Hümeyra Tercanlı Alkış ◽  
Steven J Sadowsky ◽  
Ulviye Şebnem Büyükkaplan

An ideal occlusal scheme plays an important role in a good prognosis of All-on-Four applications, as it does for other implant therapies, due to the potential impact of occlusal loads on implant prosthetic components. The aim of the present three-dimensional (3D) finite element analysis (FEA) study was to investigate the stresses on abutments, screws and prostheses that are generated by occlusal loads via different occlusal schemes in the All-on-Four concept. Three-dimensional models of the maxilla, mandible, implants, implant substructures and prostheses were designed according to the All-on-Four concept. Forces were applied from the occlusal contact points formed in maximum intercuspation and eccentric movements in canine guidance occlusion (CGO), group function occlusion (GFO) and lingualized occlusion (LO). The von Mises stress values for abutment and screws and deformation values for prostheses were obtained and results were evaluated comparatively. It was observed that the stresses on screws and abutments were more evenly distributed in GFO. Maximum deformation values for prosthesis were observed in the CFO model for lateral movement both in the maxilla and mandible. Within the limits of the present study, GFO may be suggested to reduce stresses on screws, abutments and prostheses in the All-on-Four concept.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Charles Savoldelli ◽  
Elodie Ehrmann ◽  
Yannick Tillier

AbstractWith modern-day technical advances, high sagittal oblique osteotomy (HSOO) of the mandible was recently described as an alternative to bilateral sagittal split osteotomy for the correction of mandibular skeletal deformities. However, neither in vitro nor numerical biomechanical assessments have evaluated the performance of fixation methods in HSOO. The aim of this study was to compare the biomechanical characteristics and stress distribution in bone and osteosynthesis fixations when using different designs and placing configurations, in order to determine a favourable plating method. We established two finite element models of HSOO with advancement (T1) and set-back (T2) movements of the mandible. Six different configurations of fixation of the ramus, progressively loaded by a constant force, were assessed for each model. The von Mises stress distribution in fixations and in bone, and bony segment displacement, were analysed. The lowest mechanical stresses and minimal gradient of displacement between the proximal and distal bony segments were detected in the combined one-third anterior- and posterior-positioned double mini-plate T1 and T2 models. This suggests that the appropriate method to correct mandibular deformities in HSOO surgery is with use of double mini-plates positioned in the anterior one-third and posterior one-third between the bony segments of the ramus.


2017 ◽  
Vol 7 ◽  
pp. 219-223
Author(s):  
Beril Demir Karamanli ◽  
Hülya Kılıçoğlu ◽  
Armagan Fatih Karamanli

Aims The aim of this study is to evaluate the effects of the chincup appliance used in the treatment of Class III malocclusions, not only on the mandible or temporomandibular joint (TMJ) but also on all the craniofacial structures. Materials and Methods Chincup simulation was performed on a three-dimensional finite element (FE) model. 1000 g (500 g per side) force was applied in the direction of chin-condyle head. Nonlinear FE analysis was used as the numerical analysis method. Results By the application of chincup, stresses were distributed not only on TMJ or mandible but also on the circummaxillary sutures and other craniofacial structures. Conclusions Clinical changes obtained by chincup treatment in Class III malocclusions are not limited by only mandible. It was seen that also further structures were affected.


Author(s):  
Jifeng Wang ◽  
Qubo Li ◽  
Norbert Mu¨ller

A mechanical and optimal analyses procedure is developed to assess the stresses and deformations of Novel Wound Composite Axial-Impeller under loading conditions particular to centrifuge. This procedure is based on an analytical method and Finite Element Analysis (FEA, commercial software ANSYS) results. A low-cost, light-weight, high-performance, composite turbomachinery impeller from differently designed patterns will be evaluated. Such impellers can economically enable refrigeration plants using water as a refrigerant (R718). To create different complex patterns of impellers, MATLAB is used for creating the geometry of impellers, and CAD software UG is used to build three-dimensional impeller models. Available loading conditions are: radial body force due to high speed rotation about the cylindrical axis and fluid forces on each blade. Two-dimensional plane stress and three-dimensional stress finite element analysis are carried out using ANSYS to validate these analytical mechanical equations. The von Mises stress is investigated, and maximum stress and Tsai-Wu failure criteria are applied for composite material failure, and they generally show good agreement.


2012 ◽  
Vol 215-216 ◽  
pp. 847-850
Author(s):  
Shou Jun Wang ◽  
Xing Xiong ◽  
Hong Jie Wang

In the condition of alternating impact ,the nut-supports subassembly is analyzed according to uncertainty of design parameters. Firstly, a three-dimensional (3-D) finite element (FE) model of the nut-supports subassembly is built and is meshed,and the constraints and loads are imposed.Secondly,the model of nut-supports was assembled using the software ANSYS to understand the stress distribution and various parts of the deformation of the nut-supports and its weak links in the harmonic forces.Finally,socket head cap screw has not enough pre-load in the condition of alternating impact and will be simplified.It is analyzed and checked whether it is cut or not; which provides the reference data for design and optimization of the wave maker.


2012 ◽  
Vol 201-202 ◽  
pp. 741-744 ◽  
Author(s):  
Zhen Ning Hou ◽  
Jun Wu ◽  
Qing Wang ◽  
Hong Gen Tian ◽  
Nan Chao ◽  
...  

A finite element approach based on Ansys is developed to simulate stress intensity distribution in a three dimensional model of coupling clamp joint, which includes ferrules, pipe caps and bolts. The characteristics of stress intensity distributions of coupling clamp joint under strength pressure loading have been studied by means of the non-linear finite element method. The FE model can also predict the clamp quality and tolerances to be expected under different process conditions and define the most effective process parameters to influence the tolerances. The study could give us a better understanding on the mechanism and basis for optimization design of the coupling clamp joint.


2013 ◽  
Vol 273 ◽  
pp. 588-592
Author(s):  
Zhi Yuan Yan ◽  
Dong Mei Wu ◽  
Li Tao Zhang ◽  
Jun Zhao

In order to obtain high-quality analytical results of the finite element model, it is essential to construct a three dimensional geometric model. The paper reconstructed an accurate three dimensional geometric model of cervical spine segments (C4-C7). The process of reconstruction included three-dimensional reconstruction, smooth processing, contour generation, grid generation and fitting surface. Moreover, the result of reconstruction was evaluated ultimately. The model was validated to be smooth and reasonable, and could meet the requirements of finite element analysis. The method is not merely applied to reconstruct the geometric model of the cervical spine. It is a way to construct the model of the skeletal system of the human body.


2020 ◽  
Vol 28 (6) ◽  
pp. 603-613 ◽  
Author(s):  
Efe Can Sivrikaya ◽  
Mehmet Sami Guler ◽  
Muhammed Latif Bekci

BACKGROUND: Zirconia has become a popular biomaterial in dental implant systems because of its biocompatible and aesthetic properties. However, this material is more fragile than titanium so its use is limited. OBJECTIVES: The aim of this study was to compare the stresses on morse taper implant systems under parafunctional loading in different abutment materials using three-dimensional finite element analysis (3D FEA). METHODS: Four different variations were modelled. The models were created according to abutment materials (zirconia or titanium) and loading (1000 MPa vertical or oblique on abutments). The placement of the implants (diameter, 5.0 × 15 mm) were mandibular right first molar. RESULTS: In zirconia abutment models, von Mises stress (VMS) values of implants and abutments were decreased. Maximum and minimum principal stresses and VMS values increased in oblique loading. VMS values were highest in the connection level of the conical abutments in all models. CONCLUSIONS: Using conical zirconia abutments decreases von Mises stress values in abutments and implants. However, these values may exceed the pathological limits in bruxism patients. Therefore, microfractures may be related to the level of the abutment.


Sign in / Sign up

Export Citation Format

Share Document