Performance Evaluation of Cascade Filtration with High Flow Rate Recirculating Plasma on the Secondary Filter

1987 ◽  
Vol 10 (2) ◽  
pp. 121-128 ◽  
Author(s):  
G. Busnach ◽  
A. Dal Col ◽  
M.L. Perrino ◽  
B. Brando ◽  
C. Brunati ◽  
...  

Cascade filtration (CF) has been performed in 67 on-line procedures in 9 normolipidemic patients with paraproteinemic disorders. A modified dead-end technique has been employed, with high flow rate recirculating plasma on the plasma fractionation filter (QD recycled CF), and an albumin-rich, globulin-poor filtrate was reinfused into the patient. Postprocedure recoveries were 81 ± 15% for albumin, 55 ± 23% for IgM and 48% for cryocrit, with an increase in A/G ratio from 1.8 to 2.1. An improvement was observed also in antiatherogenic/atherogenic lipoproteins ratio, suggesting a possible use of this technique in the treatment of familial hypercholesterolemia. Plasma primary separation was obtained by centrifugation or by filtration, and no significant differences were observed on subsequent protein fractionation process. An albumin priming of the plasmafractionation circuit accounted for an additional 13% saving in postprocedure level. Different surface area secondary filters have been employed: with larger surfaces, larger volumes were processed without any increase in the waste volume and with reduced need for washouts, but with an additional loss of small molecules possibly due to entrapping onto the membrane.

1992 ◽  
Vol 6 (5) ◽  
pp. 409-412 ◽  
Author(s):  
M. Yang ◽  
Fang Ming ◽  
J. Hubble ◽  
A. D. Lockett ◽  
R. R. Rathbone ◽  
...  

2018 ◽  
Vol 152 ◽  
pp. 02015
Author(s):  
Yoong Sion Ong ◽  
Ken Sim Ong ◽  
Y.k. Tan ◽  
Azadeh Ghadimi

A conventional design of rainwater harvesting system collects and directs the rainwater through water piping from roof of building to the water storage. The filtration system which locates before the water tank storage and first flush bypass system is the main focus of the research. A filtration system consists of a control volume of filter compartment, filter screen (stainless steel mesh) and water piping that direct the water flow. The filtration efficiency of an existing filter “3P Volume Filter VF1” by industrial company is enhanced. A full scale filter design prototype with filter screen of 1000 μm stainless steel metal mesh is tested to compare with the original filter system design. Three types of water inlet setups are tested. Among the proposed water inlet setups, the 90° inlet setup with extension provides the best filtration rate per unit time, following by the 45° inlet setup. The 45° and 90° inlet setup has similar filtration efficiency at low to medium flow rate while 45° inlet setup has better efficiency at high flow rate. The filtration efficiency with the 90° inlet setup with extension is observed to maintain at highest value at medium to high flow rate. The overall filtration performance achieved by the 90° inlet setup with extension at low to high flow rate is between 34.1 to 35.7%.


1992 ◽  
Vol 96 (3) ◽  
pp. 1228-1233 ◽  
Author(s):  
Laszlo Gyorgyi ◽  
Richard J. Field ◽  
Zoltan Noszticzius ◽  
William D. McCormick ◽  
Harry L. Swinney

2017 ◽  
Vol 18 (3) ◽  
pp. 188-195 ◽  
Author(s):  
Tapio Lantela ◽  
Matti Pietola

2019 ◽  
Author(s):  
Luis Vergara ◽  
Francisco Bacellar ◽  
Marcelo Neves ◽  
Arthur Watson ◽  
Grant Harris

2017 ◽  
Vol 51 (19) ◽  
pp. 11224-11234 ◽  
Author(s):  
Tina Šantl-Temkiv ◽  
Pierre Amato ◽  
Ulrich Gosewinkel ◽  
Runar Thyrhaug ◽  
Anaïs Charton ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document