scholarly journals The Impact of Anticoagulation on COVID-19 (SARS CoV-2) Patient Outcomes: A Systematic Review

2021 ◽  
pp. 089719002110150
Author(s):  
Dovena Lazaridis ◽  
Simon Leung ◽  
Lisa Kohler ◽  
Carla Hawkins Smith ◽  
Margaretta L. Kearson ◽  
...  

Background: Emerging data suggest that coagulopathy, cytokine storm, and acute respiratory distress syndrome are associated with the 2019 coronavirus disease (COVID-19). The prevalence of hypercoagulable state in these patients is unknown, but appears to be higher compared to those with other critically ill patients. Elevated D-dimer, large blood vessels clots, deep vein thrombosis, pulmonary embolism and disseminated intravascular coagulation have been reported in patients diagnosed with COVID-19 either on admission or during hospitalization and may be predictors of poor outcomes. Methods: We performed a comprehensive literature review using the search terms of COVID-19; severe acute respiratory syndrome coronavirus-2, coagulopathy, thrombosis and anticoagulation in PubMed, Ovid, google scholar, Medline and EMBASE databases from December 2019 to May 30, 2020. Results: A total of 64 relevant studies were reviewed; of which, 4 studies met the inclusion criteria and were included for analysis. The majority of the studies were retrospective involving 525 critically ill COVID-19 patients. The most commonly studied anticoagulant administered was low molecular weight heparins. Anticoagulation dosing varied throughout the studies and may be classified as standard venous thromboembolism prophylaxis, intermediate dosing, or full dose anticoagulation. The most studied objective was improvement in coagulopathy. Significant reduction in D-dimer, improvement in coagulopathy markers such as Interlukin-6, fibrinogen degradation product level, as well as lymphocyte count were reported. Conclusion: Despite the limited quality of studies analyzed, prophylaxis and higher intensity dosed anticoagulation is associated with improved pulmonary oxygenation, decreased coagulopathy markers and decreased mortality in COVID-19 patients.

2016 ◽  
Vol 8 (2) ◽  
pp. 237-240 ◽  
Author(s):  
Christopher A. March ◽  
Gretchen Scholl ◽  
Renee K. Dversdal ◽  
Matthew Richards ◽  
Leah M. Wilson ◽  
...  

ABSTRACT  With the widespread adoption of electronic health records (EHRs), there is a growing awareness of problems in EHR training for new users and subsequent problems with the quality of information present in EHR-generated progress notes. By standardizing the case, simulation allows for the discovery of EHR patterns of use as well as a modality to aid in EHR training.Background  To develop a high-fidelity EHR training exercise for internal medicine interns to understand patterns of EHR utilization in the generation of daily progress notes.Objective  Three months after beginning their internship, 32 interns participated in an EHR simulation designed to assess patterns in note writing and generation. Each intern was given a simulated chart and instructed to create a daily progress note. Notes were graded for use of copy-paste, macros, and accuracy of presented data.Methods  A total of 31 out of 32 interns (97%) completed the exercise. There was wide variance in use of macros to populate data, with multiple macro types used for the same data category. Three-quarters of notes contained either copy-paste elements or the elimination of active medical problems from the prior days' notes. This was associated with a significant number of quality issues, including failure to recognize a lack of deep vein thrombosis prophylaxis, medications stopped on admission, and issues in prior discharge summary.Results  Interns displayed wide variation in the process of creating progress notes. Additional studies are being conducted to determine the impact EHR-based simulation has on standardization of note content.Conclusions


Blood ◽  
2020 ◽  
Vol 136 (Supplement 1) ◽  
pp. 38-38
Author(s):  
Cong Zhang ◽  
Jialan Shi ◽  
Changjun WU ◽  
Chunxu Wang ◽  
Xinyi Zhao ◽  
...  

Background:The prevalence of deep vein thrombosis in hospitalized patients with COVID-19 is higher and is associated with adverse outcomes. However, the treatment options received by patients with different classifications are different, and previous studies have not discussed the differences in specific coagulation parameters between patients with mild, severe, and critically ill COVID-19. Aim:To investigate the change in coagulation function and the incidence of low limb venous thromboembolic events in mild/severe/critically ill patients with COVID-19. Methods:A retrospective analysis of coagulation parameters and lower extremity venous ultrasound examination results in 77 patients with laboratory-confirmed COVID-19 admitted to the first affiliated hospital of Harbin Medical University. We discussed the occurrence of vascular complications in patients with normal, severe and critically ill patients Rate and explore the nature of such vascular events. The anticoagulation dose was left to the discretion of the treating physician based on the individual risk of thrombosis and patients were classified as treated with prophylactic anticoagulation or therapeutic anticoagulation. Approval was obtained from the local institutional review board and all procedures were performed in accordance with the Declaration of Helsinki. Results:The incidence of low limb venous thromboembolic events in COVID-19 patients included in the study was 28.6% (22/77). A total of 22 cases with deep vein thrombosis, 13 of whom with multiple thrombosis events, and 9 cases with independent distal deep vein thrombosis. There were 0 cases, 8 cases (17.4%) and 14 cases (87.5%) of patients with deep vein thrombosis occurred in mild, severe and critically ill patients, respectively. There were 4 cases (50%) and 9 cases (64.29%) of severe and critically ill patients with multiple deep vein thrombosis events, respectively. There was no difference in age and gender between patients with lower extremity venous thrombosis and those without. The mortality rate of patients with thrombotic events has an upward trend; the mortality rate of patients with thrombosis is 18.18%, and the mortality rate of patients without thrombosis is 3.64%. Compared with mild patients, white blood cell counts, neutrophil percentage, fibrinogen, IL-6, IL-10 serum levels are higher in severe and critically ill patients. The patients whose ultrasonography reported thrombosis mostly showed a dynamic increase and/or a significant increase in D-dimer. The patients whose ultrasonography reported no thrombosis showed mildly elevated D-dimer or within the normal range. Conclusions:The development of massive venous thrombotic events, as observed in our study cohort, suggests the possibility of COVID-19 associated hypercoagulability and endothelial activation and/or dysfunction in affected individuals. Figure Disclosures No relevant conflicts of interest to declare.


2006 ◽  
Vol 12 (4) ◽  
pp. 421-426 ◽  
Author(s):  
Fredrik Lindberg ◽  
Martin Björck ◽  
Ib Rasmussen ◽  
Rickard Nyman ◽  
David Bergqvist

To investigate the rate of deep vein thrombosis (DVT) after laparoscopic surgery, 50 patients underwent bilateral phlebography 7-11 days after laparoscopic cholecystectomy (LC). All received thromboembolism prophylaxis, either low molecular weight heparin (LMWH) or dextran. Three patients were converted to open cholecystectomy. D-dimer was investigated preoperatively, on day 1 and on the day of phlebography. One asymptomatic DVT was found. One phlebogram was incomplete. Seven phlebograms were not optimal but of sufficient quality to rule out DVT. The frequency of DVT was thus 1 of 49 or 2.0% (95% confidence interval, 0-6.0%). No anticoagulants were prescribed after discharge. No patient developed late thromboembolic complications. D-dimer values increased significantly at day 1 and were further increased at the time of phlebography. The frequency of phlebographical DVTs thus seems to be low despite prophylaxis of questionable efficacy. The D-dimer values, however, suggest that the effects of LC on coagulation/fibrinolysis have a duration of longer than 1 week.


1991 ◽  
Vol 65 (01) ◽  
pp. 028-032 ◽  
Author(s):  
B Boneu ◽  
G Bes ◽  
H Pelzer ◽  
P Sié ◽  
H Boccalon

SummaryThis study was performed to determine the accuracy of D-Dimer fibrin derivatives, thrombin-antithrombin III (TAT) complexes and prothrombin fragments 1 + 2 (F 1 + 2) determinations for the diagnosis of deep vein thrombosis (DVT). One hundred and sixteen consecutive patients referred to the angiology unit of our hospital for a clinically suspected DVT were investigated. They were submitted to mercury strain gauge plethysmography and to ultrasonic duplex scanning examination; in cases of inconclusive results or of proximal DVT (n = 35), an ascending phlebography was performed. After these investigations were completed, the diagnosis of DVT was confirmed in 34 and excluded in 82. One half of the patients were already under anticoagulant therapy at the time of investigation. The 3 biological markers were assayed using commercially available ELISA techniques and the D-Dimer was also assayed with a fast latex method. The normal distribution of these markers was established in 40 healthy blood donors. The most accurate assay for the diagnosis of DVT was the D-Dimer ELISA which had both a high sensitivity (94%) and a high negative predictive value (95%). The D-Dirner latex, TAT complexes and F 1 + 2 were far less sensitive and provided negative predictive values which ranged between 78 and 85%. In spite of positive and significant correlations between the levels of ihe 3 markers, their association did not improve their overall accuracy for detecting D\/L Therefore, with the exception of the D-Dimer ELISA, these markers were of little value for the diagnosis of DVT in this specific population.


1996 ◽  
Vol 75 (03) ◽  
pp. 412-416 ◽  
Author(s):  
Armando D’Angelo ◽  
Gabriella D’Alessandro ◽  
Loredana Tomassini ◽  
Jean Louis Pittet ◽  
G Dupuy ◽  
...  

SummaryThe sensitivity and specificity for deep vein thrombosis (DVT) of a new rapid, quantitative and precise (total imprecision < 10%) D-dimer assay suitable for individual measurements (VIDAS D-DIMER, bio-Merieux, France) were evaluated in a consecutive series of 103 in- and out-patients submitted to serial compression ultrasonography (C-US) for the clinical suspicion of DVT (n = 66) or of DVT recurrence (n = 37) and symptoms lasting from 1 to 15 days. DVT was found in 22 patients at baseline testing and no patient with an initially negative C-US developed vein incompressibility at follow up. The time elapsed from the onset of symptoms was negatively associated with D-dimer levels both in patients with and in those without DVT. In the entire series of patients, the sensitivity of a positive D-dimer test (≥1.0 Μg/ml) for the presence of DVT was 96% (21/22 patients, 95% confidence interval 75-100%) with a specificity of 75% (64-84%), a negative predictive value of 98% (90-100%), a positive predictive value of 51% (35-67%), and an overall accuracy of 80% (70-87%). A normal D-dimer value (0.22 Μg/ml) was observed in one patient with DVT and symptoms lasting from 15 days. The approach of withholding C-US testing in patients with symptoms lasting from less than 11 days and D-dimer levels below the cut-off value was compared to serial C-US testing alone in a cost-effectiveness analysis subdividing the 66 patients with a first episode according to their clinical pretest probability of DVT. Thrombosis was detected in 6.7% of the patients in the low probability group (n = 15), 16.7% of the patients in the moderate probability group (n = 24), 51.9% of the patients in the high probability group (n = 27) and 8.1% of patients with suspected DVT recurrence. Calculated cost-savings for each DVT diagnosed ranged from 5% in the high pretest probability group to 55% in the low pretest probability group and to 77% in patients with suspected DVT recurrence.The safety of avoiding C-US testing in symptomatic patients with a negative D-dimer test should be evaluated in clinical management studies.


1996 ◽  
Vol 76 (04) ◽  
pp. 518-522 ◽  
Author(s):  
A Elias ◽  
I Aptel ◽  
B Huc ◽  
J J Chale ◽  
F Nguyen ◽  
...  

SummaryThe current D-Dimer ELISA methods provide high sensitivity and negative predictive value for the diagnosis of deep vein thrombosis but these methods are not suitable for emergency or for individual determination. We have evaluated the performance of 3 newly available fast D-Dimer assays (Vidas D-Di, BioMerieux; Instant IA D-Di, Stago; Nycocard D-Dimer, Nycomed) in comparison with 3 classic ELISA methods (Stago, Organon, Behring) and a Latex agglutination technique (Stago). One-hundred-and-seventy-one patients suspected of presenting a first episode of deep vein thrombosis were investigated. A deep vein thrombosis was detected in 75 patients (43.8%) by ultrasonic duplex scanning of the lower limbs; in 11 of them the thrombi were distal and very limited in size (<2 cm). We compared the performance of the tests by calculating their sensitivity, specificity, positive and negative predictive value for different cut-off levels and by calculating the area under ROC curves. The concordance of the different methods was evaluated by calculating the kappa coefficient. The performances of the 3 classic ELISA and of the Vidas D-Di were comparable and kappa coefficients indicated a good concordance between the results provided by these assays. Their sensitivity slightly declined for detection of the very small thrombi. Instant IA D-Di had a non-significantly lower sensitivity and negative predictive value than the 4 previous assays; however its performance was excellent for out-patients. As expected, the Latex assay had too low a sensitivity and negative predictive value to be recommended. In our hands, Nycocard D-Dimer also exhibited low sensitivity and negative predictive value, which were significantly improved when the plasma samples were tested by the manufacturer. Thus significant progress has been made, allowing clinical studies to be planned to compare the safety and cost-effectiveness of D-Dimer strategy to those of the conventional methods for the diagnosis of venous thrombosis.


1997 ◽  
Vol 77 (03) ◽  
pp. 602-603 ◽  
Author(s):  
J Y Borg ◽  
H Lévesque ◽  
N Cailleux ◽  
C Franc ◽  
M F Hellot ◽  
...  

2021 ◽  
Vol 16 (1) ◽  
Author(s):  
Jian Xiang Wu ◽  
Jiang Hui Qing ◽  
Yao Yao ◽  
Dong Yang Chen ◽  
Qing Jiang

Abstract Purpose To compare the specificity and sensitivity of preoperative D-dimer and age-adjusted D-dimer value for predicting the incidence of the DVT preoperatively in total joint arthroplasty (TJA) patients. Methods We enrolled 406 patients finally above 50 years old. Everyone had done ultrasonography bedside, and D-dimer concentrations were collected before surgery. The D-dimer and age-adjusted D-dimer cut-off was calculated by multiple logistic regression and receiver operating curve (ROC) analyses. Results A total of 39 patients had found asymptomatic deep vein thrombosis (DVT) by ultrasonography. The age (odds ratio [OR] 1.067; p = 0.003) and D-dimer (OR 1.331; p = 0.025) were related to the existence of DVT. For conventional D-dimer and age-adjusted D-dimer value, the area under the curves (AUCs) were 0.685 (0.499–0.696) and 0.795 (0.611–0.881), respectively. Conclusion Compared to traditional D-dimer, age-adjusted D-dimer showed better performance in screening DVT, which was useful clinically.


Sign in / Sign up

Export Citation Format

Share Document