scholarly journals The role of air pollution and lung function in cognitive impairment

2018 ◽  
Vol 51 (2) ◽  
pp. 1701963 ◽  
Author(s):  
Anke Hüls ◽  
Andrea Vierkötter ◽  
Dorothea Sugiri ◽  
Michael J. Abramson ◽  
Ulrich Ranft ◽  
...  

Air pollution has been associated with impaired lung and cognitive function, especially impairment in visuo-construction performance (VCP). In this article, we evaluate whether the effect of air pollution on VCP is mediated by lung function.We used data from the SALIA cohort (baseline 1985–1994 and follow-up 2007–2010) including 587 women aged 55 years at baseline. Particulate matter (PM) and nitrogen dioxide (NO2) exposures at baseline were estimated via land-use regression models. Lung function was characterised by averages between baseline and follow-up. We used age- and height-controlled Global Lung Initiative (GLI) z-scores of forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC. VCP was assessed at follow-up with the CERAD-Plus neuropsychological test battery and causal mediation analysis was conducted.An increase of one interquartile range in FEV1 and FVC was positively associated with VCP (β=0.18 (95% CI 0.02–0.34) and β=0.23 (95% CI 0.07–0.39), respectively). The proportion of the association between NO2 on VCP mediated by FEV1 was 6.2% and this was higher in never smokers (7.2%) and non-carriers of the APOE-ε4 allele (11.2%). However, none of the mediations were statistically significant.In conclusion, air pollution associated VCP was partially mediated by lung function. Further studies on the mechanisms underlying this pathway are required to develop new strategies to prevent air pollution induced cognitive impairment.

2019 ◽  
Vol 53 (4) ◽  
pp. 1801780 ◽  
Author(s):  
Anke Hüls ◽  
Dorothee Sugiri ◽  
Michael J. Abramson ◽  
Barbara Hoffmann ◽  
Holger Schwender ◽  
...  

IntroductionThe beneficial effect of improving air quality on lung function in the elderly remains unclear. We examined associations between decline in air pollutants and lung function, and effect modifications by genetics and body mass index (BMI), in elderly German women.MethodsData were analysed from the prospective SALIA (Study on the influence of Air pollution on Lung function, Inflammation and Aging) study (n=601). Spirometry was conducted at baseline (1985–1994; age 55 years), in 2007–2010 and in 2012–2013. Air pollution concentrations at home addresses were determined for each time-point using land-use regression models. Global Lung Initiative 2012 z-scores were calculated. Weighted genetic risk scores (GRSs) were determined from lung function-related risk alleles and used to investigate interactions with improved air quality. Multiple linear mixed models were fitted.ResultsAir pollution levels decreased substantially during the study period. Reduction of air pollution was associated with an increase in z-scores for forced expiratory volume in 1 s (FEV1) and the FEV1/forced vital capacity ratio. For a decrease of 10 µg·m−3 in nitrogen dioxide (NO2), the z-score for FEV1 increased by 0.14 (95% CI 0.01–0.26). However, with an increasing number of lung function-related risk alleles, the benefit from improved air quality decreased (GRS×NO2 interaction: p=0.029). Interactions with BMI were not significant.ConclusionsReduction of air pollution is associated with a relative improvement of lung function in elderly women, but also depends on their genetic make-up.


2015 ◽  
Vol 46 (2) ◽  
pp. 355-363 ◽  
Author(s):  
Tricia L. Larose ◽  
Ben M. Brumpton ◽  
Arnulf Langhammer ◽  
Carlos A. Camargo ◽  
Yue Chen ◽  
...  

The association between serum 25-hydroxyvitamin D (25(OH)D) level and lung function changes in the general population remains unclear.We conducted cross-sectional (n=1220) and follow-up (n=869) studies to investigate the interrelationship of serum 25(OH)D, smoking and lung function changes in a random sample of adults from the Nord-Trøndelag Health (HUNT) Study, Norway.Lung function was measured using spirometry and included forced expiratory volume in 1 s (FEV1) % predicted, forced vital capacity (FVC) % pred and FEV1/FVC ratio. Multiple linear and logistic regression models estimated the adjusted difference in lung function measures or lung function decline, adjusted odds ratios for impaired lung function or development of impaired lung function and 95% confidence intervals.40% of adults had serum 25(OH)D levels <50 nmol·L−1. Overall, those with a serum 25(OH)D level <50 nmol·L−1 showed worse lung function and increased odds of impaired lung function compared to the ≥50 nmol·L−1 group. These associations tended to be stronger among ever-smokers, including greater decline in FEV1/FVC ratio and greater odds of the development of impaired lung function (FEV1/FVC <70% OR 2.4, 95% CI 1.2–4.9). Associations among never-smokers were null. Results from cross-sectional and follow-up studies were consistent. There were no associations between serum 25(OH)D levels and lung function or lung function changes in never-smokers, whereas significant associations were observed in ever-smokers.


2016 ◽  
Vol 48 (6) ◽  
pp. 1602-1611 ◽  
Author(s):  
Arnulf Langhammer ◽  
Ane Johannessen ◽  
Turid L. Holmen ◽  
Hasse Melbye ◽  
Sanja Stanojevic ◽  
...  

We studied the fit of the Global Lung Function Initiative (GLI) all-age reference values to Norwegians, compared them with currently used references (European Community for Steel and Coal (ECSC) and Zapletal) and estimated the prevalence of obstructive lung disease.Spirometry data collected in 30 239 subjects (51.7% females) aged 12–90 years in three population-based studies were converted to z-scores.We studied healthy non-smokers comprising 2438 adults (57.4% females) aged 20–90 years and 8725 (47.7% female) adolescents aged 12–19 years. The GLI-2012 prediction equations fitted the Norwegian data satisfactorily. Median±sd z-scores were respectively 0.02±1.03, 0.01±1.04 and −0.04±0.91 for forced expiratory volume in 1 s (FEV1), forced vital capacity (FVC) and FEV1/FVC in males, and −0.01±1.02, 0.07±0.97 and −0.21±0.82 in females. The ECSC and Zapletal references significantly underestimated FEV1 and FVC. Stricter criteria of obstruction (FEV1/FVC <GLI-2012 lower limit of normal (LLN)) carried a substantially higher risk of obstructive characteristics than FEV1/FVC <0.7 and >GLI-2012 LLN. Corresponding comparison regarding myocardial infarction showed a four-fold higher risk for women.The GLI-2012 reference values fit the Norwegian data satisfactorily and are recommended for use in Norway. Correspondingly, the FEV1/FVC GLI-2012 LLN identifies higher risk of obstructive characteristics than FEV1/FVC <0.7.


Author(s):  
John S Ji ◽  
Linxin Liu ◽  
Yi Zeng ◽  
Lijing L Yan

Abstract Forkhead Box O 3 (FOXO3) genotype is strongly associated with human longevity and may be protective against neurodegeneration. Air pollution is a risk factor for cognitive decline and dementia. We aimed to study the individual and combined effects of FOXO3 and air pollution on cognitive function in a large prospective cohort with up to 14 years of follow-up. We measured cognitive function and impairment using the Mini-Mental State Examination (MMSE). We used tagging SNPs rs2253310, rs2802292, and rs4946936 to identify the FOXO3 gene, of which roughly half of the population had the longevity associated polymorphism. We matched annual average fine particulate matter (PM2.5) concentrations within 1 km^2 grid. We conducted cross-sectional and longitudinal analyses using multivariable linear and logistic regression models and generalized estimating equation. At baseline, carriers of the longevity associated homozygous minor alleles of FOXO3 SNPs had a higher MMSE score than the carriers of homozygous major alleles. In the longitudinal follow-up, carriers of FOXO3 homozygous minor alleles had lower odds of cognitive impairment compared to non-carriers. Higher PM2.5 was associated with a lower MMSE score and higher odds of cognitive impairment. The positive effects of FOXO3 were the strongest in females, older people, and residents in areas with lower air pollution.


2001 ◽  
Vol 163 (2) ◽  
pp. 356-361 ◽  
Author(s):  
CHRISTIAN SCHINDLER ◽  
NINO KÜNZLI ◽  
JEAN-PIERRE BONGARD ◽  
PHILIPPE LEUENBERGER ◽  
WERNER KARRER ◽  
...  

2020 ◽  
Vol 77 (6) ◽  
pp. 386-392 ◽  
Author(s):  
Kristin J Cummings ◽  
Marcia L Stanton ◽  
Kathleen Kreiss ◽  
Randy J Boylstein ◽  
Ju-Hyeong Park ◽  
...  

ObjectivesFour machine manufacturing facility workers had a novel occupational lung disease of uncertain aetiology characterised by lymphocytic bronchiolitis, alveolar ductitis and emphysema (BADE). We aimed to evaluate current workers’ respiratory health in relation to job category and relative exposure to endotoxin, which is aerosolised from in-use metalworking fluid.MethodsWe offered a questionnaire and spirometry at baseline and 3.5 year follow-up. Endotoxin exposures were quantified for 16 production and non-production job groups. Forced expiratory volume in one second (FEV1) decline ≥10% was considered excessive. We examined SMRs compared with US adults, adjusted prevalence ratios (aPRs) for health outcomes by endotoxin exposure tertiles and predictors of excessive FEV1 decline.ResultsAmong 388 (89%) baseline participants, SMRs were elevated for wheeze (2.5 (95% CI 2.1 to 3.0)), but not obstruction (0.5 (95% CI 0.3 to 1.1)). Mean endotoxin exposures (range: 0.09–28.4 EU/m3) were highest for machine shop jobs. Higher exposure was associated with exertional dyspnea (aPR=2.8 (95% CI 1.4 to 5.7)), but not lung function. Of 250 (64%) follow-up participants, 11 (4%) had excessive FEV1 decline (range: 403–2074 mL); 10 worked in production. Wheeze (aPR=3.6 (95% CI 1.1 to 12.1)) and medium (1.3–7.5 EU/m3) endotoxin exposure (aPR=10.5 (95% CI 1.3 to 83.1)) at baseline were associated with excessive decline. One production worker with excessive decline had BADE on subsequent lung biopsy.ConclusionsLung function loss and BADE were associated with production work. Relationships with relative endotoxin exposure indicate work-related adverse respiratory health outcomes beyond the sentinel disease cluster, including an incident BADE case. Until causative factors and effective preventive strategies for BADE are determined, exposure minimisation and medical surveillance of affected workforces are recommended.


Thorax ◽  
2020 ◽  
Vol 75 (9) ◽  
pp. 771-779 ◽  
Author(s):  
Min Zhou ◽  
Lili Xiao ◽  
Shijie Yang ◽  
Bin Wang ◽  
Tingming Shi ◽  
...  

BackgroundExposure to zinc was suggested to be associated with pulmonary damage, but whether zinc exposure affects lung function remains unclear.ObjectivesTo quantify the association between urinary zinc and lung function and explore the potential mechanisms.MethodsUrinary zinc and lung function were measured in 3917 adults from the Wuhan-Zhuhai cohort and were repeated after 3 years of follow-up. Indicators of systemic inflammation (C reactive protein), lung epithelium integrity (club cell secretory protein-16) and oxidative damage (8-hydroxy-2′-deoxyguanosine and 8-isoprostane) were measured at baseline. Linear mixed models were used to estimate the exposure–response relationship between urinary zinc and lung function. Mediation analyses were conducted to assess mediating roles of inflammation and oxidative damage in above relationships.ResultsEach 1-unit increase in log-transformed urinary zinc values was associated with a 35.72 mL decrease in forced vital capacity (FVC) and a 24.89 mL decrease in forced expiratory volume in 1 s (FEV1) in the baseline analyses. In the follow-up analyses, there was a negative association between urinary zinc and FVC among participants with persistent high urinary zinc levels, with an estimated change of −93.31 mL (95% CI −178.47 to −8.14). Furthermore, urinary zinc was positively associated with restrictive ventilatory impairment. The mediation analyses suggested that C reactive protein mediated 8.62% and 8.71% of the associations of urinary zinc with FVC and FEV1, respectively.ConclusionUrinary zinc was negatively associated with lung function, and the systemic inflammation may be one of the underlying mechanisms.


2015 ◽  
Vol 47 (3) ◽  
pp. 742-750 ◽  
Author(s):  
Suneela Zaigham ◽  
Per Wollmer ◽  
Gunnar Engström

The use of baseline lung function in the prediction of chronic obstructive pulmonary disease (COPD) hospitalisations, all-cause mortality and lung function decline was assessed in the population-based “Men Born in 1914” cohort.Spirometry was assessed at age 55 years in 689 subjects, of whom 392 had spirometry reassessed at age 68  years. The cohort was divided into three groups using fixed ratio (FR) and lower limit of normal (LLN) criterion: forced expiratory volume in 1 s (FEV1)/vital capacity (VC) ≥70%, FEV1/VC <70% but ≥LLN (FR+LLN−), and FEV1/VC <70% and <LLN (FR+LLN+).Over 44 years of follow-up, 88 men were hospitalised due to COPD and 686 died. Hazard ratios (95% CI) for incident COPD hospitalisation were 4.15 (2.24–7.69) for FR+LLN− and 7.88 (4.82–12.87) for FR+LLN+ (reference FEV1/VC ≥70%). Hazard ratios for death were 1.30 (0.98–1.72) for FR+LLN− and 1.58 (1.25–2.00) for FR+LLN+. The adjusted FEV1 decline between 55 and 68 years of age was higher for FR+LLN− and FR+LLN+ relative to the reference. Of those with FR+LLN− at 55 years, 53% had progressed to the FR+LLN+ group at 68 years.Airflow obstruction at age 55 years is a powerful risk factor for future COPD hospitalisations. The FR+LLN− group should be carefully evaluated in clinical practice in relation to future risks and potential benefit from early intervention. This is reinforced by the increased FEV1 decline in this group.


2019 ◽  
Vol 34 (2) ◽  
pp. 211-218
Author(s):  
Toluwanimi Mobolade Oni ◽  
Godson R.E.E. Ana

Abstract Background There is an increasing range of adverse health effects associated with air pollution at very low concentrations. Few studies have assessed respiratory parameters among filling station attendants. Objectives This study assessed air pollutants; particulate matter (PM10) and total volatile organic compounds (TVOC) concentrations at filling stations as well as determined forced expiratory volume in one second (FEV1) and peak expiratory flow rate (PEFR) levels among filling station attendants. Methods A cross-sectional study was conducted to assess PM10 and TVOC concentrations at 20 systematically selected filling stations in Ibadan North Local Government Area, Ibadan for 2 months using a Thermo Scientific pDR 1500 PM10 monitor and SF2000-TVOC meter. FEV1 and PEFR levels were measured in order to assess the effect of exposure to PM10 and TVOC on lung function of 100 filling station attendants using a PIKO-1 Electronic peakflow/FEV1 meter. Results Total mean PM10 concentrations (μg/m3) in the morning (43.7±16.5) and afternoon (27.8±7.9) were significantly lower (p<0.01) than the World Health Organization (WHO) guideline limit (50 μg/m3). Total mean TVOC concentrations (ppm) in the morning (12.0±3.4) and afternoon (5.6±2.4) were however significantly higher (p<0.01) than the Occupational Safety and Health Administration (OSHA) guideline limit (3 ppm). Mean FEV1 for filling station attendants was 1.63±0.39 and PEFR was 171.7±45.9. Conclusion Filling stations are hotspots for the emission of VOCs and PM10. However, filling station attendants in this study are at risk of exposure to high concentrations of VOCs but not PM10. FEV1 and PEFR values among filling station attendants were very low which could possibly be attributed to extended exposure to air pollutants. Regular medical examinations should also be conducted on filling station attendants in order to aid early detection of deviations in their health status.


Sign in / Sign up

Export Citation Format

Share Document