scholarly journals Influence of peracetic acid-ethanol sterilisation on the biomechanical properties of human meniscus transplants

2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Volker Eras ◽  
Josefine Graffunder ◽  
Norus Ahmed ◽  
Jan C. Brune

Abstract Purpose Meniscus allograft transplantation (MAT) is a possible treatment for patients suffering with pain after meniscectomy. Here, peracetic acid (PAA) sterilised meniscus transplants were investigated on whether they would provide an adequate alternative to fresh-frozen transplants in their viscoelastic and mechanical properties. Methods In this analysis, 31 menisci donors (26 male and 5 female) were included. The average donor age was 49.87 years, ranging from 32 to 65 years. Menisci of matched pairs of knees underwent chemical sterilisation while counterparts were left fresh-frozen. Stiffness and load to failure were determined via suture retention. Further menisci were analysed while attached to the tibial bone block using a novel test device to mimic physiological load distribution. Meniscus relaxation, stiffness and failure loads were determined. Histology and biphasic properties of the menisci were examined and results were analysed using paired t-tests. Results A novel custom built test device allowed the application of physiological loads for suture retention testing and revealed no significant differences between PAA sterilised (14.85 ± 4.46 N/mm, 50.49 ± 17.01 N) and fresh-frozen (18.26 ± 4.46 N/mm, 59.49 ± 21.07 N) regarding stiffness and failure load, respectively. Furthermore, initial 200 N loading showed significantly higher strain in sterilised menisci (18.87 ± 1.56) compared to fresh frozen (13.81 ± 1.04). Load relaxation experiments demonstrated significantly lower relaxation for sterilised menisci (77.71 ± 1.62) compared to fresh-frozen (89.11 ± 1.00, p-value < 0.0001). Conclusion Peracetic acid sterilised human menisci performed equally to fresh-frozen counterparts in a suture retention test and in physiological failure testing providing an adequate alternative. However, meniscus relaxation, biphasic properties and strain were shown to be significantly different between the groups. A common problem of MAT is graft extrusion or shrinkage, therefore the parameters measured here should be considered and may influence meniscus extrusion after transplantation. Level of evidence n/a (experimental study)

Hand ◽  
2017 ◽  
Vol 13 (3) ◽  
pp. 313-318 ◽  
Author(s):  
Aakash Chauhan ◽  
Patrick Schimoler ◽  
Mark C. Miller ◽  
Alexander Kharlamov ◽  
Gregory A. Merrell ◽  
...  

Background: The aim of the study was to compare biomechanical strength, repair times, and repair values for zone II core flexor tendon repairs. Methods: A total of 75 fresh-frozen human cadaveric flexor tendons were harvested from the index through small finger and randomized into one of 5 repair groups: 4-stranded cross-stitch cruciate (4-0 polyester and 4-0 braided suture), 4-stranded double Pennington (2-0 knotless barbed suture), 4-stranded Pennington (4-0 double-stranded braided suture), and 6-stranded modified Lim-Tsai (4-0 looped braided suture). Repairs were measured in situ and their repair times were measured. Tendons were linearly loaded to failure and multiple biomechanical values were measured. The repair value was calculated based on operating room costs, repair times, and suture costs. Analysis of variance (ANOVA) and Tukey post hoc statistical analysis were used to compare repair data. Results: The braided cruciate was the strongest repair ( P > .05) but the slowest ( P > .05), and the 4-stranded Pennington using double-stranded suture was the fastest ( P > .05) to perform. The total repair value was the highest for braided cruciate ( P > .05) compared with all other repairs. Barbed suture did not outperform any repairs in any categories. Conclusions: The braided cruciate was the strongest of the tested flexor tendon repairs. The 2-mm gapping and maximum load to failure for this repair approached similar historical strength of other 6- and 8-stranded repairs. In this study, suture cost was negligible in the overall repair cost and should be not a determining factor in choosing a repair.


Author(s):  
Mandeep S. Virk ◽  
Saleh S. Aiyash ◽  
Rachel M. Frank ◽  
Christopher S. Mellano ◽  
Elizabeth F. Shewman ◽  
...  

Abstract Introduction Management of the subscapularis during shoulder arthroplasty is controversial. The purpose of this study was to compare the biomechanical performance of subscapularis peel (SP) and lesser tuberosity osteotomy (LTO) in a cadaveric model. Methods The subscapularis and proximal humerus were dissected from all soft tissues in 21 fresh-frozen human cadaveric shoulders and randomized to undergo SP, LTO, or standard subscapularis tenotomy (ST, control). For SP and LTO, six #5 sutures were passed through eyelets in the implant (on lateral border and through drill holes in bicipital groove [2] and under trunion [4]). Double-row repair was performed using two lateral row transosseous sutures and four medial row sutures through the tendon (SP) or osseotendinous junction (LTO). Biomechanical properties and mode of failure were tested. Results There were no significant differences in elongation amplitude, cyclic elongation, or maximum load to failure between the three groups (P > 0.05). Mean stiffness was significantly higher in LTO (P = 0.009 vs. SP and ST). In the ST group, 7/7 specimens failed at the tendon-suture interface. For SP, 4/7 failed at the tendon-suture interface, one at the suture-bone interface, one fractured around the implant stem, and one at the knots. For LTO, 3/7 failed at the tendon-suture interface, two at the suture-bone interface and two fractured around the implant stem. Conclusions In this cadaveric model, subscapularis repair via ST, SP, and LTO techniques was biomechanically equivalent. Additional studies are needed to confirm these findings and determine the influence of biologic healing on healing rates and clinical outcomes. Level of evidence N/a, biomechanical laboratory study


2016 ◽  
Vol 2016 ◽  
pp. 1-8 ◽  
Author(s):  
ZiYing Wu ◽  
Chong Zhang ◽  
Peng Zhang ◽  
TianWu Chen ◽  
ShiYi Chen ◽  
...  

Purpose. To compare the biomechanical properties of 3 suture-bridge techniques for rotator cuff repair. Methods. Twelve pair-matched fresh-frozen shoulder specimens were randomized to 3 groups of different repair types: the medially Knotted Suture Bridge (KSB), the medially Untied Suture Bridge (USB), and the Modified Suture Bridge (MSB). Cyclic loading and load-to-failure test were performed. Parameters of elongation, stiffness, load at failure, and mode of failure were recorded. Results. The MSB technique had the significantly greatest load to failure (515.6±78.0 N, P=0.04 for KSB group; P<0.001 for USB group), stiffness (58.0±10.7 N/mm, P=0.005 for KSB group; P<0.001 for USB group), and lowest elongation (1.49±0.39 mm, P=0.009 for KSB group; P=0.001 for USB group) among 3 groups. The KSB repair had significantly higher ultimate load (443.5±65.0 N) than USB repair (363.5±52.3 N, P=0.024). However, there was no statistical difference in stiffness and elongation between KSB and USB technique (P=0.396 for stiffness and P=0.242 for elongation, resp.). The failure mode for all specimens was suture pulling through the cuff tendon. Conclusions. Our modified suture bridge technique (MSB) may provide enhanced biomechanical properties when compared with medially knotted or knotless repair. Clinical Relevance. Our modified technique may represent a promising alternative in arthroscopic rotator cuff repair.


2020 ◽  
Vol 7 (1) ◽  
Author(s):  
Guanqi Hang ◽  
Andy Khye Soon Yew ◽  
Siaw Meng Chou ◽  
Yoke Rung Wong ◽  
Shian Chao Tay ◽  
...  

Abstract Purpose The aim of this study was to (1) develop suture techniques in repairing radial meniscal tear; (2) to compare the biomechanical properties of the proposed repair techniques with the conventional double horizontal technique. Methods Thirty-six fresh-frozen porcine medial menisci were randomly assigned into four groups and a complete tear was made at the midline of each meniscus. The menisci were subsequently repaired using four different repair techniques: double vertical (DV), double vertical cross (DVX), hybrid composing one vertical and one horizontal stitch, and conventional double horizontal (DH) suture technique with suturing parallel to the tibia plateau. The conventional double horizontal group was the control. The repaired menisci were subjected to cyclic loading followed by the load to failure testing. Gap formation and strength were measured, stiffness was calculated, and mode of failure was recorded. Results Group differences in gap formation were not statistically significant at 100 cycles (p = .42), 300 cycles (p = .68), and 500 cycles (p = .70). A trend was found toward higher load to failure in DVX (276.8 N, p < .001), DV (241.5 N, p < .001), and Hybrid (237.6 N, p < .001) compared with DH (148.5 N). Stiffness was also higher in DVX (60.7 N/mm, p < .001), DV (55.3 N/mm, p < .01), and Hybrid (52.1 N/mm, p < .01), than DH group (30.5 N/mm). Tissue failure was the only failure mode observed in all specimens. Conclusion Our two proposed vertical suture techniques, as well as the double vertical technique, had superior biomechanical properties than the conventional technique as demonstrated by higher stiffness and higher strength.


2018 ◽  
Vol 39 (7) ◽  
pp. 836-842 ◽  
Author(s):  
Fred T. Finney ◽  
Simon Lee ◽  
Jaron Scott ◽  
Todd A. Irwin ◽  
James R. Holmes ◽  
...  

Background: Lesser toe metatarsal-phalangeal (MTP) joint instability can be a major source of pain and dysfunction. Instability occurs when there is incompetence of the plantar plate and/or collateral ligaments. Newer operative treatments focus on performing anatomic repairs of the plantar plate. The goal of this study was to compare the biomechanical properties of 3 suture configurations that may be used for plantar plate repairs. Methods: Biomechanical analysis of 27 lesser toe plantar plates from fresh frozen human cadavers was completed. The plantar plate was detached from the proximal phalanx, and suture was placed in the distal plantar plate in a horizontal mattress, luggage-tag, or Mason-Allen suture configuration. Cyclic loading followed by load-to-failure testing was performed. Results: There was a significant difference in peak load-to-failure force between constructs (mattress: 115.53 ± 15.95 N; luggage-tag 102.42 ± 19.33 N; Mason-Allen: 89.96 ± 15.78 N; P = .015). Post hoc analysis demonstrated that the mattress configuration had significantly higher load-to-failure force compared with the Mason-Allen configuration ( P = .004). There were no significant differences between the mattress and the luggage-tag configurations or the luggage-tag and the Mason-Allen configurations. There were no differences in construct stiffness, axial displacement at the time of failure, or number of cycles required to produce 2 mm of displacement. Conclusion: The mattress configuration demonstrated better peak load-to-failure force compared with the Mason-Allen configuration but was not statistically different from the luggage-tag configuration. Although not significant, the mattress configuration trended toward higher load-to-failure force compared with the luggage-tag. Clinical Relevance: The horizontal mattress stitch may be the biomechanically superior configuration in plantar plate repairs.


2021 ◽  
Vol 6 (2) ◽  
pp. 247301142110126
Author(s):  
Jeffrey Donahue ◽  
Ademola Shofoluwe ◽  
Kurt Krautmann ◽  
Emilio Grau-Cruz ◽  
Stephen Becher ◽  
...  

Background: Fractures of the talus are a rare but challenging injury. This study sought to quantify the area of osseous exposure afforded by a posteromedial approach to the talus and medial malleolar osteotomy. Methods: Five fresh-frozen cadaveric lower extremities were dissected using a posteromedial approach and medial malleolar osteotomy respectively. Following exposure, the talar surfaces directedly visualized were marked and captured using a calibrated digital image. The digital images were then analyzed using ImageJ software (National Institutes of Health) to calculate the surface area of the exposure. Results: The average square area of talus exposed using the posteromedial approach was 9.70 cm2 (SD = 2.20, range 7.20-12.46). The average quantity of talar exposure expressed as a percentage was 9% (SD = 1.58, range 7.03-10.40). The average square area of talus exposed using a medial malleolar osteotomy was 14.32 cm2 (SD = 2.00, range 11.26-16.66). The average quantity of talar exposure expressed as a percentage was 12.94% (SD = 1.79, range 9.97-14.73). The posteromedial approach provided superior visualization of the posterior talus, whereas the medial malleolar osteotomy offered greater access to the medial body. Conclusion: The posteromedial approach and medial malleolar osteotomy allow for significant exposure of the talus, yielding 9.70 and 14.32 cm2, respectively. Given the differing portions of the talus exposed, surgeons may prefer to use the posteromedial approach for operative fixation of posterior process fractures and elect to use a medial malleolar osteotomy in cases requiring more extensive medial and distal exposure for neck or neck/body fractures. Level of Evidence: Level IV.


2021 ◽  
pp. 036354652110095
Author(s):  
Danko Dan Milinkovic ◽  
Christian Fink ◽  
Christoph Kittl ◽  
Petri Silanpää ◽  
Elmar Herbst ◽  
...  

Background: In contrast to the majority of existing techniques for reconstruction of the medial patellofemoral ligament (MPFL), the technique described in this article uses the adductor magnus muscle tendon to gain a flat, broad graft, leaving its distal femoral insertion intact, and does not require drilling within or near the femoral physis. It also allows for soft tissue patellar fixation and could facilitate anatomic MPFL reconstruction in skeletally immature patients. Purpose: To evaluate the anatomic and structural properties of the native MPFL and the adductor tendon (AT), followed by biomechanical evaluation of the proposed reconstruction. Study Design: Descriptive laboratory study. Methods: The morphological and topographical features of the AT and MPFL were evaluated in 12 fresh-frozen cadaveric knees. The distance between the distal insertion of the AT on the adductor tubercle and the adductor hiatus, as well as the desired length of the graft, was measured to evaluate this graft’s application potential. Load-to-failure tests were performed to determine the biomechanical properties of the proposed reconstruction construct. The construct was placed in a uniaxial testing machine and cyclically loaded 500 times between 5 and 50 N, followed by load to failure, to measure the maximum elongation, stiffness, and maximum load. Results: The mean ± SD length of the AT was 12.6 ± 1.5 cm, and the mean distance between the insertion on the adductor tubercle and adductor hiatus was 10.8 ± 1.3 cm, exceeding the mean desired length of the graft (7.5 ± 0.5 cm) by 3.3 ± 0.7 cm. The distal insertion of the AT was slightly proximal and posterior to the insertion of the MPFL. The maximum elongation after cyclical loading was 1.9 ± 0.4 mm. Ultimately, the mean stiffness and load to failure were 26.2 ± 7.6 N/mm and 169.7 ± 19.2 N, respectively. The AT graft failed at patellar fixation in 2 of the initially tested specimens and at the femoral insertion in the remaining 10. Conclusion: The described reconstruction using the AT has potential for MPFL reconstruction. The AT graft presents a graft of significant volume, beneficial anatomic topography, and adequate tensile properties in comparison with the native MPFL following the data from previously published studies. Clinical Relevance: Given its advantageous anatomic relationship as an application that avoids femoral drilling and osseous patellar fixation, the AT may be considered a graft for MPFL reconstruction in skeletally immature patients.


2013 ◽  
Vol 17 (2) ◽  
pp. 296-306 ◽  
Author(s):  
Daniel Deluiz ◽  
Luciano Santos Oliveira ◽  
Fábio Ramôa Pires ◽  
Eduardo Muniz Barretto Tinoco

2018 ◽  
Vol 46 (8) ◽  
pp. 1857-1862 ◽  
Author(s):  
Dayne T. Mickelson ◽  
Thomas Lefebvre ◽  
Ken Gall ◽  
Jonathan C. Riboh

Background: Adjustable-loop cortical buttons for femoral fixation of bone-tendon-bone grafts have potential advantages over interference screw fixation; however, these devices have not been benchmarked biomechanically against interference screws. Purpose/Hypothesis: The purpose was to compare the time zero biomechanical properties of commercially available, adjustable-loop cortical button and metallic interference screws for femoral fixation of bone-tendon-bone grafts. It was hypothesized that no significant differences would be found in biomechanical properties between fixation techniques. Study Design: Controlled laboratory study. Methods: Adjustable-loop cortical buttons (n = 8) and metallic interference screws (n = 8) were used to fix matched pairs of human bone-tendon-bone allografts in porcine distal femurs. These constructs were preconditioned (10 N to 50 N at 1 Hz, 10 cycles), subjected to cyclic loading (50 N to 250 N at 1 Hz, 500 cycles), and then pulled to failure at 20 mm/min. Results: The loads to failure (mean ± SD, 700 ± 256 N vs 688 ± 215 N, P = .92) and linear stiffnesses (219 ± 48 N/mm vs 218 ± 49 N/mm, P = .97) for the adjustable-loop cortical button and metallic interference screws, respectively, were not significantly different. Cyclic displacement was higher in the adjustable-loop cortical button group (2.1 ± 0.6 mm vs 1.3 ± 0.4 mm, P = .01). The mechanism of failure was different between groups, with bone block slippage occurring most commonly in the interference screw group (n = 5) and fracture of the bone block through the suture hole occurring most commonly in the adjustable-loop cortical button group (n = 6). Conclusion: Adjustable-loop cortical buttons and interference screws have similar time zero failure loads, although cyclic displacement was higher with the adjustable-loop cortical buttons. The mean difference in displacement was less than 1 mm compared with the interference screw. Clinical Relevance: Adjustable-loop cortical buttons may be an acceptable alternative to an interference screw for femoral fixation of bone-tendon-bone grafts in anterior cruciate ligament reconstruction. The clinical relevance of the observed differences in cyclic displacement is unknown and should be evaluated in future studies.


2020 ◽  
Vol 48 (9) ◽  
pp. 2081-2089
Author(s):  
Luciano A. Rossi ◽  
Ignacio Tanoira ◽  
Tomás Gorodischer ◽  
Ignacio Pasqualini ◽  
Domingo Luis Muscolo ◽  
...  

Background: There is a lack of evidence in the literature comparing outcomes between the classic and the congruent arc Latarjet procedures in athletes. Purpose: To compare return to sports, functional outcomes, and complications between the classic and the congruent arc Latarjet procedures in athletes with recurrent glenohumeral instability. Study Design: Cohort study; Level of evidence, 3. Methods: Between June 2009 and June 2017, 145 athletes with recurrent anterior glenohumeral instability underwent surgery with the Latarjet as a primary procedure in our institution. The classic procedure was used in 66 patients, and the congruent arc method was used in 79 patients. Return to sports, range of motion (ROM), the Rowe score, a visual analog scale (VAS) for pain in sports activity, and the Athletic Shoulder Outcome Scoring System (ASOSS) were used to assess functional outcomes. Recurrences were also evaluated. The postoperative bone block position and consolidation were assessed with computed tomography. Results: In the total population, the mean follow-up was 41.3 months (range, 24-90 months) and the mean age was 25.3 years (range, 18-45 years). In total, 90% of patients were able to return to sports; of these, 91% returned at their preinjury level of play. No significant difference in shoulder ROM was found between preoperative and postoperative results. The Rowe, VAS, and ASOSS scores showed statistical improvement after operation ( P < .001). The Rowe score increased from a preoperative mean of 42.8 points to a postoperative mean of 95.2 points ( P < .01). Subjective pain during sports improved from 3.2 points preoperatively to 0.7 points at last follow-up ( P < .01). The ASOSS score improved significantly from a preoperative mean of 46.4 points to a postoperative mean of 88.4 points ( P < .01). No significant differences in shoulder ROM and functional scores were found between patients who received the classic vs congruent arc procedures. There were 5 recurrences (3.5%): 3 dislocations (2%) and 2 subluxations (1%). No significant difference in the recurrence rate was noted between groups. The bone block healed in 134 cases (92%). Conclusion: In athletes with recurrent anterior glenohumeral instability, the Latarjet procedure produced excellent functional outcomes. Most athletes returned to sports at their preinjury level, and the rate of recurrence was very low, regardless of whether the patients received surgery with the classic or congruent arc technique.


Sign in / Sign up

Export Citation Format

Share Document