scholarly journals Assessment of cyclic fatigue resistance of Protaper Next and WaveOne Gold in different kinematics

2020 ◽  
Vol 44 (1) ◽  
Author(s):  
Amira Galal Ismail ◽  
Manar Galal ◽  
Nehal Nabil Roshdy

Abstract Background The purpose of the current study was to inspect and compare the influence of applying continuous rotation and reciprocation motions on the cyclic fatigue resistance of Protaper Next (PTN) file (X2) and WaveOne Gold (WOG) Primary file in simulated canals. Twenty Protaper Next files(X2) and 20 WaveOne Gold Primary files were included in this study. A cyclic fatigue testing device was employed to test the cyclic resistance of each file in different motions. The testing device has an artificial custom-made stainless-steel canal with a 60° angle of curvature and a 2-mm radius of curvature. The files were randomly divided into 4 groups; group 1: PTN in continuous rotation, group 2: PTN in reciprocation, group 3: WOG in continuous rotation and group 4: WOG in reciprocation. All the instruments were rotated until fracture occurred, and the time to fracture was recorded in seconds using a digital chronometer. The number of cycles to fracture (NCF) was calculated. The data were analyzed statistically (p < .05). Results Results represented that when using either continuous rotation motion or reciprocating motion, WOG files showed a significantly longer time until failure than PTN files (p < 0.001). The time till fracture increased significantly, when using both types of files with a reciprocating filing motion. Conclusion Within the confinement of this study, WOG file in reciprocation showed higher cyclic fatigue resistance than PTN in both continuous rotation and reciprocating motion. The reciprocating motion enhances both files behavior in terms of cyclic fatigue resistance.

2016 ◽  
Vol 10 (04) ◽  
pp. 541-545 ◽  
Author(s):  
Vadhana Sekar ◽  
Ranjith Kumar ◽  
Suresh Nandini ◽  
Suma Ballal ◽  
Natanasabapathy Velmurugan

ABSTRACT Objective: The purpose of this study was to assess the role of cross section on cyclic fatigue resistance of One Shape, Revo-S SU, and Mtwo rotary files in continuous rotation and reciprocating motion in dynamic testing model. Materials and Methods: A total of 90 new rotary One Shape, Revo-S SU, and Mtwo files (ISO size 25, taper 0.06, length 25 mm) were subjected to continuous rotation or reciprocating motion. A cyclic fatigue testing device was fabricated with 60° angle of curvature and 5 mm radius. The dynamic testing of these files was performed using an electric motor which permitted the reproduction of pecking motion. All instruments were rotated or reciprocated until fracture occurred. The time taken for each instrument to fracture was recorded. All the fractured files were analyzed under a scanning electron microscope (SEM) to detect the mode of fracture. Statistical analysis was performed using one-way ANOVA, followed by Tukey's honestly significant difference post hoc test. Results: The time taken for instruments in reciprocating motion to fail under cyclic loading was significantly longer when compared with groups in continuous rotary motion. There was a statistically significant difference between Mtwo rotary and the other two groups in both continuous and reciprocating motion. One Shape rotary files recorded significantly longer duration to fracture resistance when compared with Revo-S SU files in both continuous and reciprocating motion. SEM observations showed that the instruments of all groups had undergone a ductile mode of fracture. Conclusion: Reciprocating motion improved the cyclic fatigue resistance of all tested groups.


2020 ◽  
Vol 14 (3) ◽  
pp. 177-180
Author(s):  
Ahmet Demirhan Uygun

Background. This study aimed to compare the VDW.ROTATE instruments with the Reciproc Blue instruments in different kinematics in terms of the cyclic fatigue resistance. Methods. Sixty instruments, 40 VDW.ROTATE and 20 Reciproc Blue instruments, were divided into three groups (n=20): VDW.ROTATE was used in both continuous rotation and reciprocation, and Reciproc Blue was used in reciprocation only. The cyclic fatigue resistance test was carried out in an artificial canal (60°, r=3 mm) at an intracanal temperature of 35±2°C until fracture, and the time to fracture was recorded in seconds. The data were analyzed statistically using Kruskal–Wallis and Tamhane’s T2 tests (P<0.05). Results. DAll the reciprocating motion groups resulted in a longer mean duration to failure than the continuous rotation motion group (P<0.05). Conclusion. It was observed that the Reciproc Blue instruments had higher cyclic fatigue resistance than VDW.ROTATE instruments (P<0.05). Recent studies have shown that reciprocal movement increases cyclic fatigue resistance compared to rotational movement. The VDW.ROTATE instrument, which has a similar size, design, and alloy as the Reciproc Blue instrument, can also be used by clinicians in reciprocating motion with endo motors capable of reciprocating in different directions. However, even if the cyclic fatigue resistance increases by using VDW.ROTATE instruments in reciprocation, the cyclic fatigue resistance is lower than Reciproc Blue instruments.


2020 ◽  
Vol 2020 ◽  
pp. 1-4
Author(s):  
Abdullah Mahmoud Riyahi ◽  
Amr Bashiri ◽  
Khalid Alshahrani ◽  
Saad Alshahrani ◽  
Hadi M. Alamri ◽  
...  

TruNatomy (TN; Dentsply Sirona, Maillefer, Ballaigues, Switzerland) is a newly released system that was not tested in any previous studies. The objective of this work is to evaluate cyclic fatigue resistance of the new file and compare it with the Twisted Files (TF) and ProTaper Next (PTN). Forty-five files were distributed into 3 groups: PTN X2 (size 25 and taper 0.06), TF (size 25 and taper 0.06), and TN prime file (size 26 and taper 0.04). Each group included 15 files. Lengths of all files were 25 mm. Cyclic fatigue testing was done using artificial stainless-steel canals with 60-degree curvature and 5 mm radius. Continuous rotation movement at 300 rpm was used until the file fractures. Time for file separation was recorded in seconds. The number of cycles to failure (NCF) mean and standard deviation for each group was calculated. For statistical analysis of data, ANOVA and Tukey’s multiple comparison test were used. Mean and standard deviation (SD) of NCF were 259 ± 37.2, 521.67 ± 63.07 and 846.67 ± 37.16 for PTN, TF, and TN respectively. TN on average had significantly the highest NCF compared with PTN (p<0.05) and TF (p<0.05). TruNatomy file showed superior cyclic fatigue resistance. With its potential to preserve tooth structure, this file offers a good cyclic fatigue advantage. However, future studies are required to evaluate other properties of this file and to examine its clinical performance.


2021 ◽  
Author(s):  
Mohammad Al-Obaida ◽  
Khalid Merdad ◽  
Ali Alkhamis ◽  
Muneer Khan Mohammed ◽  
Rahaf Al-Obaida ◽  
...  

Abstract BackgroundThe aim of this study was to compare cyclic fatigue resistance (CFR) and separation patterns during rotating movement of five heat-treated nickel titanium files in both single and double-curved canals. MethodsCFR was compared between five groups of 24 files each: HyFlex® EDM, HyFlex™ CM, Vortex Blue®, Protaper Next®, and One Curve, by determining the time needed to fracture (TTF) and the number of cycles to failure (NCF) in a cyclic fatigue testing device with a single 5-mm radius of curvature (ROC) and 60° angle, and a double curvature; coronal curvature (5 mm ROC and 60° angle) and apical curvature (2 mm ROC and 70° angle). The separation pattern was evaluated, and file fragment separated length were measured. One-way ANOVA and Tukey’s post-hoc were used to compare statistical differences between the groups. Scanning Electron Microscope (SEM) was used to investigate the fracture sites. Results HyFlex™ CM files displayed significantly higher CFR, followed by HyFlex® EDM and Vortex Blue® in single curvature canals, and Protaper Next® (PTN) in the double curvature canals, as observed by TFF and NCF. PTN group had the highest tendency for files to extrude apically after separation in both curvatures. ConclusionHyFlex™ CM instruments have superior resistance to cyclic flexural fatigue within single canals with single and double curvatures, followed by HyFlex® EDM and Vortex Blue® instruments. Protaper Next® files followed by One Curve had the highest tendency to extrude apically after separationClinical relevanceHyFlex™ CM instruments showed the highest safety in preparing canals with single or double curvatures, considering CFR.


2017 ◽  
Vol 31 (2) ◽  
pp. 78-82
Author(s):  
Massimo Amato ◽  
Giuseppe Pantaleo ◽  
Dina Abdellatif ◽  
Andrea Blasi ◽  
Roberto Lo Giudice ◽  
...  

Aim: The aim of present study was to compare cyclic fatigue resistance of three modern Ni-Ti instruments used with continuous rotation. Materials and methods: For this study 3 groups of rotating instruments with continuous rotation (HyFlex EDM, Twisted File Adaptive, Revo S SU) have been used, each group consisted of 20 files. The various groups were subjected to cyclic fatigue testing through an artificial metal device. A statistical analysis with Kruskal-Wallis test and Mann-Whitney test was performed. Results: There were statistically significant differences between the three groups. The HyFlex EDM instruments have a fracture resistance slightly higher than the Twisted file and far higher than Revo S SU. Conclusions: Modern Ni-Ti alloys increase resistance of the rotating instruments to cyclic fatigue.


2014 ◽  
Vol 40 (7) ◽  
pp. 995-999 ◽  
Author(s):  
Sekar Vadhana ◽  
Balasubramanian SaravanaKarthikeyan ◽  
Suresh Nandini ◽  
Natanasabapathy Velmurugan

2015 ◽  
Vol 03 (01) ◽  
pp. 012-019
Author(s):  
Ankita Sood ◽  
Varun Jindal ◽  
Ajay Chhabra ◽  
Arvind Arora ◽  
Ankur Vats

Abstract Aim: The aim of this study was to evaluate the apical transportation, centering ability and cyclic fatigue resistance of Hero shaper, Twisted file, Hyflex file and RACE rotary file systems. Methods: Mesiobuccal roots of eighty maxillary molars were divided into four groups and instrumented with Hero shaper, Twisted file, Hyflex file and RACE rotary file systems with a final apical size being 25/.04. Apical deviation was assessed by the radiographic platform method that enables obtaining superimposed images of the first and last instrument used in root canal preparation in the same radiograph. Apical transportation was measured in millimeters with the aid of the AUTOCAD 2008 software. Forty canals were sectioned at 7mm from the apex and stereomicroscopic Images were taken at 6x magnification before and after instrumentation for evaluation of centering ability. The cyclic fatigue testing was conducted with the instrumentrotating freely at angles of curvature of 45 degree. Total 10 instruments were tested in each group. The instruments were rotated at 400rpm using the X-smart motor (Dentsply, Maillefer) until fracture occurred. Results: There was no statistically significant difference between the four groups in apical transportation and centering ability whereas twisted files showed the maximum cyclic fatigue resistance. Conclusion: The different rotary file systems provided minimum canal transportation and the twisted file performed significantly better in terms of cyclic fatigue resistance.


2016 ◽  
Vol 10 (1) ◽  
pp. 704-713 ◽  
Author(s):  
Fredson Marcio Acris de Carvalho ◽  
Leonardo Cantanhede de Oliveira Gonçalves ◽  
André Augusto Franco Marques ◽  
Vanessa Alves ◽  
Carlos Eduardo da Silveira Bueno ◽  
...  

Objective: To compare cleaning effectiveness by histological analysis of a reciprocating single-file system with ProTaper rotary instruments during the preparation of curved root canals in extracted teeth. Methods: A total of 40 root canals with curvatures ranging between 20 - 40 degrees were divided into two groups of 20 canals. Canals were prepared to the following apical sizes: Reciproc size 25 (n=20); ProTaper: F2 (n=20). The normal distribution of data was tested by the Kolmogorov-Smirnov test and the values obtained for the test (Mann-Whitney U test, P < .05) were statistically analyzed using the GraphPad InStat for the Mac OS software (GraphPad Software, La Jolla, CA, USA). Results: There were no significant differences in remaining debris (P > .05) between the two groups. Conclusion: The application of reciprocating motion during instrumentation did not result in increased debris when compared with continuous rotation motion, even in the apical part of curved canals. Both instruments resulted in debris in the canal lumen, irrespective of the movement kinematics applied.


2018 ◽  
Vol 29 (2) ◽  
pp. 208-213 ◽  
Author(s):  
Eduarda Santiago Vaz-Garcia ◽  
Victor Talarico Leal Vieira ◽  
Natasha Pereira da Silva Ferreira Petitet ◽  
Edson Jorge Lima Moreira ◽  
Hélio Pereira Lopes ◽  
...  

Abstract The aim of the present study was to evaluate the cyclic fatigue of two anatomic finishing files: XP-Endo Finisher and XP-Clean. Roughness pattern and the micro-hardness of the files were also assessed. Instruments were subjected to cyclic fatigue resistance measuring the time to fracture in an artificial stainless-steel canal with a 60° angle and a 5-mm radius of curvature. The fracture surface of all fragments was examined with a scanning electron microscope. The roughness of the working parts was quantified by using a profilometer and the micro-hardness test was carried out using a Vickers hardness tester. Results were statistically analyzed using a student´s t-test at a significance level of P < 0.05. Weibull analysis was also performed. XP-Endo Finisher presented significantly longer cyclic fatigue life than XP-Clean instruments (P<0.05). XP-Endo Finisher was able to withstand 1000% more cycles to fracture when compared to XP-Clean instruments. SEM visual inspection of the fracture surfaces revealed fractographic characteristics of ductile fracture in all tested instruments; wide-ranging forms of dimples were identified and no plastic deformation in the helical shaft of the fractured instruments was observed. When mean life was compared XP-Endo Finisher lasted longer than XP-Clean with a probability of 99.9%. XP-Endo Finisher instruments also exhibited significantly lower roughness than XP-Clean instruments (P<0.05). No differences in the micro-hardness was observed between the files (P>0.05). It can be concluded that XP-Endo Finisher instruments showed improved performance when compared with XP-Clean instruments, demonstrating higher cyclic fatigue resistance and lower roughness.


Sign in / Sign up

Export Citation Format

Share Document