Time-activity Curves

Author(s):  
Gerhard Glatting
Keyword(s):  
1990 ◽  
Vol 29 (01) ◽  
pp. 28-34 ◽  
Author(s):  
F. C. Visser ◽  
M. J. van Eenige ◽  
G. Westera ◽  
J. P. Roos ◽  
C. M. B. Duwel

Changes in myocardial metabolism can be detected externally by registration of time-activity curves after administration of radioiodinated fatty acids. In this scintigraphic study the influence of lactate on fatty acid metabolism was investigated in the normal human myocardium, traced with 123l-17-iodoheptadecanoic acid (123l-17-HDA). In patients (paired, n = 7) lactate loading decreased the uptake of 123l-17-HDA significantly from 27 (control: 22-36) to 20 counts/min/pixel (16-31; p <0.05 Wilcoxon). The half-time value increased to more than 60 rriin (n = 5), oxidation decreased from 61 to 42%. Coronary vasodilatation, a well-known side effect of lactate loading, was studied separately in a dipyridamole study (paired, n = 6). Coronary vasodilatation did not influence the parameters of the time-activity curve. These results suggest that changes in plasma lactate level as occurring, among other effects, during exercise will influence the parameters of dynamic 123l-17-HDA scintigraphy of the heart.


1990 ◽  
Vol 29 (05) ◽  
pp. 204-209
Author(s):  
B. Ugarković ◽  
D. Ivančević ◽  
D. Babić ◽  
Ž. Babić

A method is presented which combines gastro-oesophageal reflux quantification and oesophageal transit measurement so as to differentiate true reflux from residual oesophageal activity. A group of 33 subjects with gastro-oesophageal reflux symptoms and endoscopically confirmed reflux oesophagitis and a group of 21 asymptomatic subjects with normal oesophageal, gastric and duodenal endoscopic findings were examined. The subjects were given 37 MBq 99mTc-Sn-colloid in saline orally and then scintiscanned dynamically. The gastro-oesophageal quantification was done after transit measurement and after the oesophageal time activity (to detect residual oesophageal activity) reached its minimum. The difference in the reflux indices between the two groups was highly significant. In low-grade oesophagitis measured reflux was lower than in higher grades of disease. Only 4.7% false-positive results were observed with a specificity of 95%, indicating that this method may be superior to methods published earlier.


1990 ◽  
Vol 29 (04) ◽  
pp. 170-176 ◽  
Author(s):  
M. V. Yester ◽  
Eva Dubovsky ◽  
C. D. Russell

Renal parenchymal transit time of the recently introduced radiopharmaceutical 99mTc-MAG3 (mercaptoacetylglycylglylcylglycinel) was measured in 37 kidneys, using factor analysis to separate parenchymal activity from that in the collecting system. A new factor algorithm was employed, based on prior interpolative background subtraction and use of the fact that the initial slope of the collecting system factor time-activity curve must be zero. The only operator intervention required was selection of a rectangular region enclosing the kidney (by identifying two points at opposite corners). Transit time was calculated from the factor time-activity curves both by deconvolution of the parenchymal factor curve and also by measuring the appearance time for collecting system activity from the collecting system factor curve. There was substantial agreement between the two methods. Factor analysis led to a narrower range of normal values than a conventional cortical region-of-interest method, presumably by decreasing crosstalk from the collecting system. In preliminary trials, the parenchymal transit time did not well separate four obstructed from seventeen unobstructed kidneys, but it successfully (p <0.05) separated six transplanted kidneys with acute rejection or acute tubular necrosis from 10 normal transplants.


1987 ◽  
Vol 26 (06) ◽  
pp. 248-252 ◽  
Author(s):  
M. J. van Eenige ◽  
F. C. Visser ◽  
A. J. P. Karreman ◽  
C. M. B. Duwel ◽  
G. Westera ◽  
...  

Optimal fitting of a myocardial time-activity curve is accomplished with a monoexponential plus a constant, resulting in three parameters: amplitude and half-time of the monoexponential and the constant. The aim of this study was to estimate the precision of the calculated parameters. The variability of the parameter values as a function of the acquisition time was studied in 11 patients with cardiac complaints. Of the three parameters the half-time value varied most strongly with the acquisition time. An acquisition time of 80 min was needed to keep the standard deviation of the half-time value within ±10%. To estimate the standard deviation of the half-time value as a function of the parameter values, of the noise content of the time-activity curve and of the acquisition time, a model experiment was used. In most cases the SD decreased by 50% if the acquisition time was increased from 60 to 90 min. A low amplitude/constant ratio and a high half-time value result in a high SD of the half-time value. Tables are presented to estimate the SD in a particular case.


1978 ◽  
Vol 39 (02) ◽  
pp. 474-487 ◽  
Author(s):  
E R Cole ◽  
F Bachmann ◽  
C A Curry ◽  
D Roby

SummaryA prospective study in 13 patients undergoing open-heart surgery with extracorporeal circulation revealed a marked decrease of the mean one-stage prothrombin time activity from 88% to 54% (p <0.005) but lesser decreases of factors I, II, V, VII and X. This apparent discrepancy was due to the appearance of an inhibitor of the extrinsic coagulation system, termed PEC (Protein after Extracorporeal Circulation). The mean plasma PEC level rose from 0.05 U/ml pre-surgery to 0.65 U/ml post-surgery (p <0.0005), and was accompanied by the appearance of additional proteins as evidenced by disc polyacrylamide gel electrophoresis of plasma fractions (p <0.0005). The observed increases of PEC, appearance of abnormal protein bands and concomitant increases of LDH and SGOT suggest that the release of an inhibitor of the coagulation system (similar or identical to PIVKA) may be due to hypoxic liver damage during extracorporeal circulation.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Pengcheng Hu ◽  
Xin Lin ◽  
Weihai Zhuo ◽  
Hui Tan ◽  
Tianwu Xie ◽  
...  

Abstract Purpose A 2-m axial field-of-view, total-body PET/CT scanner (uEXPLORER) has been recently developed to provide total-body coverage and ultra-high sensitivity, which together, enables opportunities for in vivo time-activity curve (TAC) measurement of all investigated organs simultaneously with high temporal resolution. This study aims at quantifying the cumulated activity and patient dose of 2-[F-18]fluoro-2-deoxy-D-glucose (F-18 FDG ) imaging by using delayed time-activity curves (TACs), measured out to 8-h post-injection, for different organs so that the comparison between quantifying approaches using short-time method (up to 75 min post-injection) or long-time method (up to 8 h post-injection) could be performed. Methods Organ TACs of 10 healthy volunteers were collected using total-body PET/CT in 4 periods after the intravenous injection of F-18 FDG. The 8-h post-injection TACs of 6 source organs were fitted using a spline method (based on Origin (version 8.1)). To compare with cumulated activity estimated from spline-fitted curves, the cumulated activity estimated from multi-exponential curve was also calculated. Exponential curve was fitted with shorter series of data consistent with clinical procedure and previous dosimetry works. An 8-h dynamic bladder wall dose model considering 2 voiding were employed to illustrate the differences in bladder wall dose caused by the different measurement durations. Organ absorbed doses were further estimated using Medical Internal Radiation Dose (MIRD) method and voxel phantoms. Results A short-time measurement could lead to significant bias in estimated cumulated activity for liver compared with long-time-measured spline fitted method, and the differences of cumulated activity were 18.38% on average. For the myocardium, the estimated cumulated activity difference was not statistically significant due to large variation in metabolism among individuals. The average residence time differences of brain, heart, kidney, liver, and lungs were 8.38%, 15.13%, 25.02%, 23.94%, and 16.50% between short-time and long-time methods. Regarding effective dose, the maximum differences of residence time between long-time-measured spline fitted curve and short-time-measured multi-exponential fitted curve was 9.93%. When using spline method, the bladder revealed the most difference in the effective dose among all the investigated organs with a bias up to 21.18%. The bladder wall dose calculated using a long-time dynamic model was 13.79% larger than the two-voiding dynamic model, and at least 50.17% lower than previous studies based on fixed bladder content volume. Conclusions Long-time measurement of multi-organ TACs with high temporal resolution enabled by a total-body PET/CT demonstrated that the clinical procedure with 20 min PET scan at 1 h after injection could be used for retrospective dosimetry analysis in most organs. As the bladder content contributed the most to the effective dose, a long-time dynamic model was recommended for the bladder wall dose estimation.


Cancers ◽  
2021 ◽  
Vol 13 (10) ◽  
pp. 2342
Author(s):  
Corentin Martens ◽  
Olivier Debeir ◽  
Christine Decaestecker ◽  
Thierry Metens ◽  
Laetitia Lebrun ◽  
...  

Recent works have demonstrated the added value of dynamic amino acid positron emission tomography (PET) for glioma grading and genotyping, biopsy targeting, and recurrence diagnosis. However, most of these studies are based on hand-crafted qualitative or semi-quantitative features extracted from the mean time activity curve within predefined volumes. Voxelwise dynamic PET data analysis could instead provide a better insight into intra-tumor heterogeneity of gliomas. In this work, we investigate the ability of principal component analysis (PCA) to extract relevant quantitative features from a large number of motion-corrected [S-methyl-11C]methionine ([11C]MET) PET frames. We first demonstrate the robustness of our methodology to noise by means of numerical simulations. We then build a PCA model from dynamic [11C]MET acquisitions of 20 glioma patients. In a distinct cohort of 13 glioma patients, we compare the parametric maps derived from our PCA model to these provided by the classical one-compartment pharmacokinetic model (1TCM). We show that our PCA model outperforms the 1TCM to distinguish characteristic dynamic uptake behaviors within the tumor while being less computationally expensive and not requiring arterial sampling. Such methodology could be valuable to assess the tumor aggressiveness locally with applications for treatment planning and response evaluation. This work further supports the added value of dynamic over static [11C]MET PET in gliomas.


Sign in / Sign up

Export Citation Format

Share Document