False-negative CTs in astrocytomas: The value of repeat scanning

Neurology ◽  
1982 ◽  
Vol 32 (7) ◽  
pp. 766-766 ◽  
Author(s):  
J. D. Wulff ◽  
P. Q. Proffitt ◽  
J. G. Panszi ◽  
D. K. Ziegler
Methodology ◽  
2019 ◽  
Vol 15 (3) ◽  
pp. 97-105
Author(s):  
Rodrigo Ferrer ◽  
Antonio Pardo

Abstract. In a recent paper, Ferrer and Pardo (2014) tested several distribution-based methods designed to assess when test scores obtained before and after an intervention reflect a statistically reliable change. However, we still do not know how these methods perform from the point of view of false negatives. For this purpose, we have simulated change scenarios (different effect sizes in a pre-post-test design) with distributions of different shapes and with different sample sizes. For each simulated scenario, we generated 1,000 samples. In each sample, we recorded the false-negative rate of the five distribution-based methods with the best performance from the point of view of the false positives. Our results have revealed unacceptable rates of false negatives even with effects of very large size, starting from 31.8% in an optimistic scenario (effect size of 2.0 and a normal distribution) to 99.9% in the worst scenario (effect size of 0.2 and a highly skewed distribution). Therefore, our results suggest that the widely used distribution-based methods must be applied with caution in a clinical context, because they need huge effect sizes to detect a true change. However, we made some considerations regarding the effect size and the cut-off points commonly used which allow us to be more precise in our estimates.


2003 ◽  
Vol 42 (02) ◽  
pp. 71-77 ◽  
Author(s):  
I. Schreivogel ◽  
C. Angerstein ◽  
U. Siefker ◽  
K. Lehmann ◽  
G. Altenvoerde ◽  
...  

SummaryAim: Formal and clinical comparison of a new 3rd-gene-ration-Tg-IRMA (3-G-IRMA; Dynotest®Tg-plus) with a conventional Tg-IRMA (3-G-IRMA; SELco®Tg-assay) for patients with differentiated thyroid carcinoma. In addition we evaluated, if thyroglobulin (Tg) levels above a specific threshold concentration indicate the need for further investigations for residual disease. Patients, methods: Tg concentration of 105 sera of 93 consecutive patients with a differentiated thyroid cancer was determined with both assays and compared at different cut-off values (Dynotest®Tg-plus: 0.2, 1, 2 ng/ml; SELco®Tg-assay: 0.5, 1, 2 ng/ml) with the clinical results in respect to the corresponding TSH concentration. Results: Tg concentration did not show any significant difference (SELco®Tg-assay 0.5 ng/ml, Dynotest® Tg-plus 0.2 ng/ml). The Tg-values of both assays correlated with 97%. However, correlation of recovery in both assays was small (40%). The sensitivities and specificities of both assays at different cut-offs and TSH values did not reveal significant differences. In patients with TSH concentration >30 µU/ml the functional assay sensitivity was superior to arbitrary cut-offs in the decision to start further evaluations. Conclusions: In our study neither formal nor clinical significant differences between two Tg-assays were found. In a hypothyroid patient (TSH >30 µU/ml, Tg concentration exceeding the functional assay sensitivity) further investigations for residual disease are warranted. Higher thresholds are of limited value, due to a inacceptable high rate of false negative results.


1974 ◽  
Vol 31 (02) ◽  
pp. 273-278
Author(s):  
Kenneth K Wu ◽  
John C Hoak ◽  
Robert W Barnes ◽  
Stuart L Frankel

SummaryIn order to evaluate its daily variability and reliability, impedance phlebography was performed daily or on alternate days on 61 patients with deep vein thrombosis, of whom 47 also had 125I-fibrinogen uptake tests and 22 had radiographic venography. The results showed that impedance phlebography was highly variable and poorly reliable. False positive results were noted in 8 limbs (18%) and false negative results in 3 limbs (7%). Despite its being simple, rapid and noninvasive, its clinical usefulness is doubtful when performed according to the original method.


Author(s):  
Brian M. Katt ◽  
Casey Imbergamo ◽  
Fortunato Padua ◽  
Joseph Leider ◽  
Daniel Fletcher ◽  
...  

Abstract Introduction There is a known false negative rate when using electrodiagnostic studies (EDS) to diagnose carpal tunnel syndrome (CTS). This can pose a management dilemma for patients with signs and symptoms that correlate with CTS but normal EDS. While corticosteroid injection into the carpal tunnel has been used in this setting for diagnostic purposes, there is little data in the literature supporting this practice. The purpose of this study is to evaluate the prognostic value of a carpal tunnel corticosteroid injection in patients with a normal electrodiagnostic study but exhibiting signs and symptoms suggestive of carpal tunnel, who proceed with a carpal tunnel release. Materials and Methods The group included 34 patients presenting to an academic orthopedic practice over the years 2010 to 2019 who had negative EDS, a carpal tunnel corticosteroid injection, and a carpal tunnel release. One patient (2.9%), where the response to the corticosteroid injection was not documented, was excluded from the study, yielding a study cohort of 33 patients. Three patients had bilateral disease, yielding 36 hands for evaluation. Statistical analysis was performed using Chi-square analysis for nonparametric data. Results Thirty-two hands (88.9%) demonstrated complete or partial relief of neuropathic symptoms after the corticosteroid injection, while four (11.1%) did not experience any improvement. Thirty-one hands (86.1%) had symptom improvement following surgery, compared with five (13.9%) which did not. Of the 32 hands that demonstrated relief following the injection, 29 hands (90.6%) improved after surgery. Of the four hands that did not demonstrate relief after the injection, two (50%) improved after surgery. This difference was statistically significant (p = 0.03). Conclusion Patients diagnosed with a high index of suspicion for CTS do well with operative intervention despite a normal electrodiagnostic test if they have had a positive response to a preoperative injection. The injection can provide reassurance to both the patient and surgeon before proceeding to surgery. Although patients with a normal electrodiagnostic test and no response to cortisone can still do well with surgical intervention, the surgeon should carefully review both the history and physical examination as surgical success may decrease when both diagnostic tests are negative. Performing a corticosteroid injection is an additional diagnostic tool to consider in the management of patients with CTS and normal electrodiagnostic testing.


Sign in / Sign up

Export Citation Format

Share Document