Second Paper: Observations of Ball to Track Contact Angles and Inclination of Ball Rolling Axis in an Angular Contact Ball Race

1970 ◽  
Vol 185 (1) ◽  
pp. 366-372
Author(s):  
D. J. Haines

Discrepancies between predicted and actual ball race performance have drawn attention to the theoretical assumptions at present in use. This paper reports an experimental study of contact angle positions and ball rolling axis inclinations from which it is concluded that centrifugal track expansions should be included in predictions of contact angle positions, and as speed is increased the ball rolling axis moves out of the centreline plane of the bearing.

Author(s):  
Gen Matsuura ◽  
Hidehira Fukaya ◽  
Emiyu Ogawa ◽  
Sota Kawakami ◽  
Hitoshi Mori ◽  
...  

Background: Local impedance (LI) can indirectly measure catheter contact and tissue temperature during radiofrequency catheter ablation (RFCA). However, data on the effects of catheter contact angle on LI parameters are scarce. This study aimed to evaluate the influence of catheter contact angle on LI changes and lesion size with 2 different LI-sensing catheters in a porcine experimental study. Methods: Lesions were created by the INTELLANAV MiFi™ OI (MiFi) and the INTELLANAV STABLEPOINT™ (STABLEPOINT). RFCA was performed with 30 watts and a duration of 30 seconds. The CF (0, 5, 10, 20, and 30 g) and catheter contact angle (30°, 45°, and 90°) were changed in each set (n=8 each). The LI rise, LI drop, and lesion size were evaluated. Results: The LI rise increased as CF increased. There was no angular dependence with the LI rise under all CFs in the MiFi. On the other hand, the LI rise at 90° was lower than at 30° under 5 and 10 g of CF in STABLEPOINT. The LI drop increased as CF increased. Regarding the difference in catheter contact angles, the LI drop at 90° was lower than that at 30° for both catheters. The maximum lesion widths and surface widths were smaller at 90° than at 30°, whereas there were no differences in lesion depths. Conclusion: The LI drop and lesion widths at 90° were significantly smaller than those at 30°, although the lesion depths were not different among the 3 angles for the MiFi and STABLEPOINT.


2021 ◽  
Vol 42 (Supplement_1) ◽  
Author(s):  
G Matsuura ◽  
H Fukaya ◽  
E Ogawa ◽  
S Kawakami ◽  
D Saito ◽  
...  

Abstract Background Local impedance (LI) at a distal tip of the ablation catheter can indirectly measure catheter contact and tissue temperature during radiofrequency catheter ablation (RFCA). LI decreases by RFCA, and a degree of LI drop is correlated with lesion size. However, data on the effects of catheter contact angle on lesion size and LI drop were scarce. This study aimed to evaluate the influence of catheter contact angle on lesion size and LI drop in a porcine experimental study. Methods Lesions were created on porcine myocardial left ventricles by the LI-sensing ablation catheter (IntellaNav MiFi OI®). Contact force (CF) was measured using pressure to current transducer (load cell). Radiofrequency ablation was performed with a power of 30 Watt and a duration of 30 seconds. CF (0g, 5g, 10g, 20g, and 30g) and catheter angle (30°, 45°, and 90°) were changed in each set (total 120 lesions, n=8 each). LI rise, LI drop by RF application, and lesion size (maximum lesion width, maximum surface width, and maximum lesion depth) were evaluated. Results There was no angular dependence in LI rise in all CF. The values of LI rise increased as CF increased. The LI drop also increased as CF increased in all contact angles. Regarding the difference of catheter angles, LI drop with 90° was lower than those with 30° and 45°in CF 10g, 20g, and 30g, respectively. Maximum lesion width and surface width were larger in 30° and 45° than those in 90°, whereas there were no differences in maximum lesion depth. Conclusion LI drop in 90° were significantly lower than those in 45° and 30°. Although lesion depths were not different among the three angles, the absolute values of LI drop were different. Caution should be exercised to comprehend the LI drop with catheter angles. FUNDunding Acknowledgement Type of funding sources: None.


Author(s):  
Rami Benkreif ◽  
Fatima Zohra Brahmia ◽  
Csilla Csiha

AbstractSurface tension of solid wood surfaces affects the wettability and thus the adhesion of various adhesives and wood coatings. By measuring the contact angle of the wood, the surface tension can be calculated based on the Young-Dupré equation. Several publications have reported on contact angle measured with different test liquids, under different conditions. Results can only be compared if the test conditions are similar. While the roles of the drop volume, image shooting time etc., are widely recognized, the role of the wood surface moisture content (MC) is not evaluated in detail. In this study, the effect of wood moisture content on contact angle values, measured with distilled water and diiodomethane, on sanded birch (Betula pendula) surfaces was investigated, in order to find the relationship between them. With increasing MC from approximately 6% to 30%, increasing contact angle (decreasing surface tension) values were measured according to a logarithmic function. The function makes possible the calculation of contact angles that correspond to different MCs.


Biomimetics ◽  
2021 ◽  
Vol 6 (2) ◽  
pp. 38
Author(s):  
Quentin Legrand ◽  
Stephane Benayoun ◽  
Stephane Valette

This investigation of morphology-wetting links was performed using a biomimetic approach. Three natural leaves’ surfaces were studied: two bamboo varieties and Ginkgo Biloba. Multiscale surface topographies were analyzed by SEM observations, FFT, and Gaussian filtering. A PDMS replicating protocol of natural surfaces was proposed in order to study the purely morphological contribution to wetting. High static contact angles, close to 135∘, were measured on PDMS replicated surfaces. Compared to flat PDMS, the increase in static contact angle due to purely morphological contribution was around 20∘. Such an increase in contact angle was obtained despite loss of the nanometric scale during the replication process. Moreover, a significant decrease of the hysteresis contact angle was measured on PDMS replicas. The value of the contact angle hysteresis moved from 40∘ for flat PDMS to less than 10∘ for textured replicated surfaces. The wetting behavior of multiscale textured surfaces was then studied in the frame of the Wenzel and Cassie–Baxter models. Whereas the classical laws made it possible to describe the wetting behavior of the ginkgo biloba replications, a hierarchical model was developed to depict the wetting behavior of both bamboo species.


2020 ◽  
Vol 146 ◽  
pp. 03004
Author(s):  
Douglas Ruth

The most influential parameter on the behavior of two-component flow in porous media is “wettability”. When wettability is being characterized, the most frequently used parameter is the “contact angle”. When a fluid-drop is placed on a solid surface, in the presence of a second, surrounding fluid, the fluid-fluid surface contacts the solid-surface at an angle that is typically measured through the fluid-drop. If this angle is less than 90°, the fluid in the drop is said to “wet” the surface. If this angle is greater than 90°, the surrounding fluid is said to “wet” the surface. This definition is universally accepted and appears to be scientifically justifiable, at least for a static situation where the solid surface is horizontal. Recently, this concept has been extended to characterize wettability in non-static situations using high-resolution, two-dimensional digital images of multi-component systems. Using simple thought experiments and published experimental results, many of them decades old, it will be demonstrated that contact angles are not primary parameters – their values depend on many other parameters. Using these arguments, it will be demonstrated that contact angles are not the cause of wettability behavior but the effect of wettability behavior and other parameters. The result of this is that the contact angle cannot be used as a primary indicator of wettability except in very restricted situations. Furthermore, it will be demonstrated that even for the simple case of a capillary interface in a vertical tube, attempting to use simply a two-dimensional image to determine the contact angle can result in a wide range of measured values. This observation is consistent with some published experimental results. It follows that contact angles measured in two-dimensions cannot be trusted to provide accurate values and these values should not be used to characterize the wettability of the system.


2021 ◽  
Vol 11 (1) ◽  
Author(s):  
Seyed Mehran Mirmohammadi ◽  
Sasha Hoshian ◽  
Ville P. Jokinen ◽  
Sami Franssila

AbstractA polydimethylsiloxane (PDMS)/Cu superhydrophobic composite material is fabricated by wet etching, electroless plating, and polymer casting. The surface topography of the material emerges from hierarchical micro/nanoscale structures of etched aluminum, which are rigorously copied by plated copper. The resulting material is superhydrophobic (contact angle > 170°, sliding angle < 7° with 7 µL droplets), electrically conductive, elastic and wear resistant. The mechanical durability of both the superhydrophobicity and the metallic conductivity are the key advantages of this material. The material is robust against mechanical abrasion (1000 cycles): the contact angles were only marginally lowered, the sliding angles remained below 10°, and the material retained its superhydrophobicity. The resistivity varied from 0.7 × 10–5 Ωm (virgin) to 5 × 10–5 Ωm (1000 abrasion cycles) and 30 × 10–5 Ωm (3000 abrasion cycles). The material also underwent 10,000 cycles of stretching and bending, which led to only minor changes in superhydrophobicity and the resistivity remained below 90 × 10–5 Ωm.


1998 ◽  
Vol 518 ◽  
Author(s):  
Sang-Ho Lee ◽  
Myong-Jong Kwon ◽  
Jin-Goo Park ◽  
Yong-Kweon Kim ◽  
Hyung-Jae Shin

AbstractHighly hydrophobic fluorocarbon films were prepared by the vapor phase (VP) deposition method in a vacuum chamber using both liquid (3M's FC40, FC722) and solid sources (perfluorodecanoic acid (CF3(CF2)8COOH), perfluorododecane (C12F26)) on Al, Si and oxide coated wafers. The highest static contact angles of water were measured on films deposited on aluminum substrate. But relatively lower contact angles were obtained on the films on Si and oxide wafers. The advancing and receding contact angle analysis using a captive drop method showed a large contact angle hysteresis (ΔH) on the VP deposited fluorocarbon films. AFM study showed poor film coverage on the surface with large hysteresis. FTIR-ATR analysis positively revealed the stretching band of CF2 groups on the VP deposited substrates. The thermal stability of films was measured at 150°C in air and nitrogen atmospheres as a function of time. The rapid decrease of contact angles was observed on VP deposited FC and PFDA films in air. However, no decrease of contact angle on them was observed in N2.


Sign in / Sign up

Export Citation Format

Share Document