Slip Factor of a Centrifugal Compressor and Its Variation with Flow Rate

1974 ◽  
Vol 188 (1) ◽  
pp. 415-421 ◽  
Author(s):  
A. Whitfield

To predict the complete performance map of turbocharger centrifugal compressors, it has been found essential to include a procedure for estimating the slip factor at off-design flow rates. The many correlations available for the slip factor only concern themselves with design-point operation and consequently only provide a single value for the slip factor. The approach presented here attempts, within the confines of a one-dimensional procedure, to recognize the changing flow pattern at the impeller discharge in order to predict the variation of slip factor with flow rate. The procedure is based upon the well-established jet-wake flow model of Dean and the overall slip factor calculated from the jet slip factor. Experimental and theoretical slip factors are presented for three impellers with 34, 30 and 12 radial blades, respectively. The complete performance map of the 12-bladed turbocharger compressor and the effect of using a constant and varying slip factor on the predicted performance are presented.

1995 ◽  
Vol 117 (4) ◽  
pp. 602-608 ◽  
Author(s):  
A. Pinarbasi ◽  
M. W. Johnson

Detailed measurements have been taken of the three-dimensional velocity field within the vaneless diffuser of a backswept low speed centrifugal compressor using hot-wire anemometry. A 16 percent below and an 11 percent above design flow rate were used in the present study. Results at both flow rates show how the blade wake mixes out more rapidly than the passage wake. Strong secondary flows inherited from the impeller at the higher flow rate delay the mixing out of the circumferential velocity variations, but at both flow rates these circumferential variations are negligible at the last measurement station. The measured tangential/radial flow angle is used to recommend optimum values for the vaneless space and vane angle for design of a vaned diffuser.


2001 ◽  
Vol 7 (3) ◽  
pp. 173-181
Author(s):  
Tong-Miin Liou ◽  
Meng-Yu Chen

Laser-Doppler velocimetry (LDV) measurements are presented of relative mean velocity and turbulence intensity components inside the impeller passage of a centrifugal fan with twelve backward curved blades at design, under-design, and over-design flow rates. Additional LDV measurements were also performed at the volute outlet to examine the uniformity of the outlet flow for the three selected flow rates. Complementary flow visualization results in the tongue region are further presented. It is found that the number of characteristic flow regions and the average turbulence level increase with decreasing air flow rate. For the case of under-design flow rate, there are a through-flow region on the suction side, a reverse flow region on the pressure side, and a shear layer region in between. The corresponding average turbulence intensity is as high as 9.1% of blade tip velocity.


1975 ◽  
Vol 189 (1) ◽  
pp. 557-565 ◽  
Author(s):  
A. Whitfield ◽  
F. J. Wallace

A procedure to predict the complete performance map of turbocharger centrifugal compressors is presented. This is based on a one-dimensional flow analysis using existing published loss correlations that were available and thermodynamic models to describe the incidence loss and slip factor variation at flow rates which differ from the design point. To predict the losses within the complete compressor stage using a one-dimensional flow procedure, it is necessary to introduce a number of empirical parameters. The uncertainty associated with these empirical parameters is assessed by studying the effect of varying them upon the individual losses and upon the overall predicted performance.


1991 ◽  
Author(s):  
Ronald D. Flack ◽  
Steven M. Miner ◽  
Ronald J. Beaudoin

Turbulence profiles were measured in a centrifugal pump with an impeller with backswept blades using a two directional laser velocimeter. Data presented includes radial, tangential, and cross product Reynolds stresses. Blade to blade profiles were measured at four circumferential positions and four radii within and one radius outside the four bladed impeller. The pump was tested in two configurations; with the impeller running centered within the volute, and with the impeller orbiting with a synchronous motion (ε/r2 = 0.016). Flow rates ranged from 40% to 106% of the design flow rate. Variation in profiles among the individual passages in the orbiting impeller were found. For several regions the turbulence was isotropic so that the cross product Reynolds stress was low. At low flow rates the highest cross product Reynolds stress was near the exit. At near design conditions the lowest cross product stress was near the exit, where uniform flow was also observed. Also, near the exit of the impeller the highest turbulence levels were seen near the tongue. For the design flow rate, inlet turbulence intensities were typically 9% and exit turbulence intensities were 6%. For 40% flow capacity the values increased to 18% and 19%, respectively. Large local turbulence intensities correlated with separated regions. The synchronous orbit did not increase the random turbulence, but did affect the turbulence in the individual channels in a systematic pattern.


Author(s):  
Matthias Hamann ◽  
Elias Chebli ◽  
Markus Müller ◽  
Alexander Krampitz

Centrifugal compressors for automotive turbochargers have large influence on the operation characteristic of combustion engines. Especially the improvement of the surge margin is one of the most important development targets. Thereby, a reliable detection of local flow phenomena within the compressor stage is necessary and a procedure to gain this information from standard measurement data is discussed in this paper. A one–dimensional calculation methodology for a single-stage centrifugal compressor with a vaneless diffuser and casing treatment is presented. The tool calculates the flow properties at the impeller inlet and exit as well as at diffuser exit, based on the measured inlet and outlet data and the geometry information of the compressor. The calculated flow characteristics are plotted within the measured compressor performance map to show local flow parameters. The unsteady recirculation flow within the casing treatment, the inflow angle and the total pressure losses are considered. The tool is validated on different compressor sizes. Thereby the compressor is equipped with static pressure measuring points at the impeller inlet and exit as well as at the diffuser exit. The calculated static pressure correlated well with the measured data with an accuracy of 2 % to 5 % on 95 % of the operating range. In this paper an experimental parameter study is executed in order to improve the surge margin. Thereby the geometry of the diffuser and the casing treatment is varied and the compressor performance is measured on a turbocharger test rig. The calculation of the flow angles and other flow characteristics within the diffuser enables one to find out whether surge is triggered through the diffuser or the impeller.


1992 ◽  
Vol 114 (2) ◽  
pp. 350-358 ◽  
Author(s):  
R. D. Flack ◽  
S. M. Miner ◽  
R. J. Beaudoin

Turbulence profiles were measured in a centrifugal pump with an impeller with backswept blades using a two-directional laser velocimeter. Data presented include radial, tangential, and cross product Reynolds stresses. Blade-to-blade profiles were measured at four circumferential positions and four radii within and one radius outside the four-bladed impeller. The pump was tested in two configurations: with the impeller running centered within the volute, and with the impeller orbiting with a synchronous motion (ε/r2 = 0.016). Flow rates ranged from 40 to 106 percent of the design flow rate. Variation in profiles among the individual passages in the oribiting impeller were found. For several regions the turbulence was isotropic so that the cross product Reynolds stress was low. At low flow rates the highest cross product Reynolds stress was near the exit. At near-design conditions the lowest cross product stress was near the exit, where uniform flow was also observed. Also, near the exit of the impeller the highest turbulence levels were seen near the tongue. For the design flow rate, inlet turbulence intensities were typically 9 percent and exit turbulence intensities were 6 percent. For 40 percent flow capacity the values increased to 18 and 19 percent, respectively. Large local turbulence intensities correlated with separated regions. The synchronous orbit did not increase the random turbulence, but did affect the turbulence in the individual channels in a systematic pattern.


1965 ◽  
Vol 87 (2) ◽  
pp. 181-188 ◽  
Author(s):  
Alfred F. Stahler

Several of the methods of explaining and evaluating the slip factor of a centrifugal impeller with straight radial blades are presented. The slip factors are calculated by these methods and compared to the experimentally observed characteristics of an impeller with 19 blades. It is shown that the slip factor depends on the gas-flow rate, the rotational speed, and the impeller-tip diameter. It is concluded that the slip-factor characteristics are better described by means of a constant leaving angle of the flow relative to the impeller and that the leaving angle is only a function of the impeller geometry.


Author(s):  
Francois G. Louw ◽  
Theodor W. von Backström ◽  
Sybrand J. van der Spuy

Large axial flow fans are used in forced draft air cooled heat exchangers (ACHEs). Previous studies have shown that adverse operating conditions cause certain sectors of the fan, or the fan as a whole to operate at very low flow rates, thereby reducing the cooling effectiveness of the ACHE. The present study is directed towards the experimental and numerical analyses of the flow in the vicinity of an axial flow fan during low flow rates. This is done to obtain the global flow structure up and downstream of the fan. A near-free-vortex fan, designed for specific application in ACHEs, is used for the investigation. Experimental fan testing was conducted in a British Standard 848, type A fan test facility, to obtain the fan characteristic. Both steady-state and time-dependent numerical simulations were performed, depending on the operating condition of the fan, using the Realizable k-ε turbulence model. Good agreement is found between the numerically and experimentally obtained fan characteristic data. Using data from the numerical simulations, the time and circumferentially averaged flow field is presented. At the design flow rate the downstream fan jet mainly moves in the axial and tangential direction, as expected for a free-vortex design criteria, with a small amount of radial flow that can be observed. As the flow rate through the fan is decreased, it is evident that the down-stream fan jet gradually shifts more diagonally outwards, and the region where reverse flow occur between the fan jet and the fan rotational axis increases. At very low flow rates the flow close to the tip reverses through the fan, producing a small recirculation zone as well as swirl at certain locations upstream of the fan.


2020 ◽  
Vol 142 (10) ◽  
Author(s):  
Hiroshi Yokoyama ◽  
Katsutake Minowa ◽  
Kohei Orito ◽  
Masahito Nishikawara ◽  
Hideki Yanada

Abstract Small axial fans are used for cooling electronic equipment and are often installed in a casing with various slits. Direct aeroacoustic simulations and experiments were performed with different casing opening ratios to clarify the effects of the flow through the casing slits on the flow field and acoustic radiation around a small axial fan. Both the predicted and measured results show that aerodynamic performance deteriorates at and near the design flow rate and is higher at low flow rates by completely closing the casing slits compared with the fan in the casing with slits. The predicted flow field shows that the vortical structures in the tip vortices are spread by the suppression of flow through the slits at the design flow rate, leading to the intensification of turbulence in the blade wake. Moreover, the pressure fluctuations on the blade surface are intensified, which increases the aerodynamic sound pressure level. The suppression of the outflow of pressurized air through the downstream part of the slits enhances the aerodynamic performance at low flow rates. Also, the predicted surface streamline at the design flow rate shows that air flows along the blade tip for the fan with slits, whereas the flow toward the blade tip appears for the fan without slits. As a result, the pressure distributions on the blade and the torque exerted on the fan blade are affected by the opening ratio of slits.


Author(s):  
Chuhua Zhang ◽  
Yongmiao Miao ◽  
Chuangang Gu

The three-dimensional turbulent flow fields in a shrouded fan impeller with backswept discharge at three operating flow rates are numerically calculated with an unstructured grid method recently developed by the authors. Reynolds-averaged Navier-Stokes (N-S) equations and k-ε equations are solved through finite volume method with pressure correction algorithm. Numerical results are presented for detailed main and secondary flow velocity. The agreements of radial velocity component at different sections at design flow rate between computations and measurements are generally good. It can be observed that different flow rates have distinctive effects on flow patterns. At design flow rate, the flow is behaved as attached flow pattern and has a relatively smooth distribution for the main flow velocity. Above the design flow rate, a sudden drop and non-smooth distribution for the main flow velocity appear at the pressure-hub corner near the impeller inlet, however, the distribution of main flow velocity becomes smooth gradually downstream. Under the design flow rate, the jet-wake structure appears obviously within the impeller passage.


Sign in / Sign up

Export Citation Format

Share Document