scholarly journals Development and Validation of a Stability-Indicating HPLC Technique for Measuring Temozolomide in its Pharmaceutical Dose Form

2021 ◽  
Vol 37 (4) ◽  
pp. 900-904
Author(s):  
Narayan Shrivas ◽  
S. K. Mishra

Using RP-HPLC, an accurate and precise technique for the measurement of Temozolomide in its pharmaceutical dose form was developed and validated. Chromatographic separation was achieved on an X Terra RP 18(250mm x 4.6mm), 5 µ column using a mobile phase consisting of methanol and buffer in the ratio of 10:990v/v. The flow rate was 1mL/min with the detection wavelength of 254 nm and retention time was found to be 20 min. The developed method was validated according to ICH guidelines. With a correlation coefficient of 0.9990, linearity was observed in the range of 50-150 percent. The %RSD of the developed method for method precision and Intermediate precision was found to be 0.65 % and 0.59 % respectively. With a percent recovery of 99.82 ±0.045, the approach was confirmed to be reliable. All of the validation parameters yielded results that were within acceptable limits. It was discovered that the procedure was accurate, exact, specific, rugged, and durable. As a result, the newly discovered approach can be used for finish product of quality control and stability testing on a regular basis and it has been confirmed to be stable for Temozolomide is available in both pure and pharmaceutical dose forms.

Author(s):  
Bhetanabotla Chandramowli ◽  
B.M Syam Kumar ◽  
D.V. R. N. Bhikshapathi ◽  
Bigala B Rajkamal

A simple, precise and accurate RP-HPLC technique was developed and the developed method was validated for the regular analysis of Boceprevir. Chromatographic analysis was performed by selecting X-Terra ODS ( C18) column (4.6 mm i.d. × 250 mm, 5μ), Acetonitrile : Phosphate buffer pH -3 ( 90 : 10% v/v) as mobile phase, 1.0 ml/min as flow rate and 20μl injection volume. The LC chromatographic peak was eluted at 3.6 min at 235 nm as UV detection wavelength. The developed method was validated as per the ICH guidelines and the Validation parameters were specificity, accuracy, linearity, precision, LOD and LOQ. Linear relationship for Boceprevir established in the concentration range of 50 to 150μg/mL. Accuracy in terms of percentage recovery found in the range between 98 to 101%. LOD and LOQ values were found to be 2.3 and 7.123μg/mL respectively. The results of the method established that the new RP-HPLC method is convenient and simple in regular analysis of Boceprevir in bulk and capsule formulation.


Author(s):  
Devi Ramesh ◽  
Mohammad Habibuddin

Objective: The objective of the present study is to develop and validate a simple, rapid, sensitive reverse phase HPLC method for the determination of Armodafinil present in bulk and its pharmaceutical formulations.Methods: The chromatographic separation was achieved by using Hypersil ODS C-18 (150 x 4.6 mm, 5µ) in an isocratic mode with mobile phase methanol: phosphate buffer 3.0 (60:40 %v/v) was used. The flow rate was 1 ml/min and effluent was monitored at 225 nm. The method was validated for validation parameters i.e. linearity, accuracy, precision and robustness according to ICH guidelines.Results: The retention time of Armodafinil was 4.2 min and the linearity range of the method was 500-20000ng/ml with regression (r2) coefficient 0.9998. The method was validated for precision, accuracy, robustness and which were found to be within the acceptable limits according to the ICH guidelines. Also, the method was successfully applied for the estimation of Armodafinil in the marketed formulation of Nuvigil and the recovery was found to be>98%.Conclusion: The developed method possess good selectivity, specificity, there is no interference found in the blank at a retention time of ARM and good correlation between the peak area and concentration of the drugs under prescribed conditions. Hence, the method can be applied for routine analysis of Armodafinil. 


2021 ◽  
Vol 37 (02) ◽  
pp. 493-498
Author(s):  
Mohan Bhatale ◽  
Neelakandan Kaliyaperumal ◽  
Gopalakrishnan Mannathusamy ◽  
Gurunathan Ramalingam

A simple, selective, linear having accuracy and specific of reverse phase high-performance liquid chromatographic (RP-HPLC) method for determination of Genotoxic impurity Hydroxylamine Hydrochloride of drug Leflunomide is reported.The separation and analysis were done on YMC Triart C18 (4.6 mm x 150 mm), having particle size 3.0 μm. KH2PO4 in 2000 mL of purified water and 2 mL triethylamine with pH 2.5 with phosphoric acid is mobile phase-A while acetonitrile is mobile Phase-B with gradient program. The elution achieved with 1.50 mL/min flow rate and using UV detection at 230 nm wavelength. Selected column oven temperature is 45°C and auto sampler 5°C respectively. In this method linearity and accuracy of Hydroxylamine HCl covered with specification limit of LOQ to 150 % (i.e.3 to 23 ppm). The observed correlation coefficient is 0.99965 and recovery in between 99.07 to 114.94. In method precision (ie.repeatability) and intermediate precision (IP) observed % RSD of six spiked test preparation is below 5.0 %. The standard and sample were stable for 3 days when stored at 2 to 8°C temperature. In robustness studies system suitability parameters ie tailing factor, theoretical plates and %RSD does not show significant changes. The present RP-HPLC method is selective, robust, linear, and precise for detection of Hydroxylamine HCl.


Author(s):  
MD. Muzaffar -ur- Rehman1 ◽  
G. Nagamallika

A simple, rapid, precise, and accurate RP-HPLC method for the estimation of Ivabradine Hydrochloride an anti-anginal agent, both as a bulk drug and in pharmaceutical formulation was developed. The chromatographic separation was achieved on a Thermosil C18 150 × 4.5 mm, 5μm column by using a mobile phase containing a mixture of methanol and phosphate buffer pH 6.5 in the ratio of 65:35 % v/v at a flow rate of 1ml/min and at an ambient temperature. The detection was monitored at a wavelength of 265nm. A clear chromatographic peak was identified with the retention time of 4.36 min and tailing factor of 1.23. The developed method was validated according to ICH guidelines with respect to specificity, linearity, accuracy, precision and robustness. The method shows a good linear relationship with correlation co-efficient of more than 0.992 in the concentration range of 30μg-150μg. The method showed mean % Recovery of 100.4% and %RSD for repeatability and intermediate precision was less than 2%. The proposed method can be used successfully for the quantitative determination of Ivabradine HCL in pharmaceutical dosage forms.


Author(s):  
Anusha Shivaraj ◽  
Shireesha Battula

A new simple, specific, accurate, precise RP-HPLC method has been developed for the estimation of Ormeloxifene. The chromatographic separation for Ormeloxifene was achieved with mobile phase containing methanol :ACN(70:30 v/v), agilent C18 column (4.6 x150 mm) 5 μ at room temperature and UV detection at 274nm.The compounds were eluted in the isocratic mode at a flow rate of 1ml/min. The retention time of Ormeloxifene was found to be 2.497min. The method was validated according to ICH guideline for linearity, specificity, precision, accuracy, LOD, LOQ and robustness in accordance with ICH guidelines.


Author(s):  
Wamorkar V V ◽  
C S Ramaa ◽  
Manjunath S Y ◽  
V Malla Reddy

RP-HPLC method has been developed and validated for the determination of voricaonazole in bulk drug. The developed method is found to be specific, reproducible, and stability indicating. The Hypersil, C18 (250 X 4.6 mm) 5μ column was used and mobile phase consisting of water:acetonitrile to achieve good resolution and retention of the analyte and its impurities. The detector linearity was established from concentrations ranging from 5-100 μg/ml. The method was tested at different levels of specificity and accuracy as per requirements given in ICH guidelines. The molecule was exposed to the stress conditions such as acid, base, oxidation, heat and light as per the recommendations of ICH guidelines. The method was proved to be robust with respect to changes in flow rate, mobile phase composition and allied columns. The proposed method is found to be sensitive, precise, rapid, reproducible, and offers good column life.


INDIAN DRUGS ◽  
2016 ◽  
Vol 53 (10) ◽  
pp. 43-47
Author(s):  
N. Mallikarjuna Rao ◽  
◽  
D. Gowri Sankar

A simple, selective, linear, precise and accurate RP-HPLC method was developed and validated for rapid assay of ascorbic acid in health drinks. Isocratic elution at a flow rate of 0.9mL/min was employed on a symmetry C18 column (250x4.6mm, 0.5μ in particle size) at ambient temperature. The mobile phase consisted of water with acetic acid: methanol 95:5% (V/V). The UV detection wavelength was 245 nm and 20μL sample was injected. The retention time for ascorbic acid was 4.61± 0.22 min. The percentage RSD for precision and accuracy of the method was found to be less than the method which was validated as per the ICH guidelines. The method was successfully applied for routine analysis of ascorbic acid in health drinks.


Author(s):  
Chaitanya A. Gulhane ◽  
Wrushali A. Panchale ◽  
Jagdish V. Manwar ◽  
Ravindra L. Bakal

A new simple, reproducible and efficient liquid chromatographic method (RP-HPLC) was developed for simultaneous estimation of thiocolchicoside and etoricoxib for tablet formulation. Formulation containing thiocolchicoside and etoricoxib is used as analgesic. Separation was achieved by Nucleosil (4.6mm I.D × 250 mm) C18 column with mobile phase consist of Acetonitrile: water (0.05% Orthophosphoric acid V/V) in the ratio 25:75 at flow rate 0.7ml . The detection was carried out at 220nm. The retention time of thiocolchicoside and etoricoxib was found to be 3.75 min and 6.13 min respectively. Linearity of THC and ETR was found to be in the range of 2-10µg/mL and 30-150µg/mL. Percent recovery obtained for THC and ETR were 99.98% and 99.69% respectively. The method was validated as per ICH guidelines.


2017 ◽  
Vol 5 (01) ◽  
pp. 48-50
Author(s):  
Uttam Kumar Agrawal ◽  
Jeyabalan Govindasamy

A new simple, accurate ,precise and reproducible RP-HPLC method has been developed for simultaneous estimation of metformin and pioglitazone in bulk drug form using proper HPLC system. The mobile phase consists of phosphate buffer and acetonitrile in the ratio of 35:65 at pH 3.4.The detection wavelength was carried out at 228 nm. The method was linear over the concentration range for metformin 50-100 μg/mL and for pioglitazone 20-180 μg/mL. The recoveries of metformin and pioglitazone were found to be 100.5 and 98.7% respectively. The validation of method was carried out utilizing ICH-guidelines. The described HPLC method method was successfully for the analysis of pharmaceutical formulations containing dosage form.


2019 ◽  
Vol 9 (3) ◽  
pp. 154-159
Author(s):  
Ashish Gorle ◽  
Jayashri Mahajan ◽  
Prathamesh Bhave

Desoximetasone chemically is 9-fluoro-IIβ21-dihydroxy-I6a-methylpregna-I.4-diene-3.The precise mechanism of the anti-inflammatory activity of topical steroids in the treatment of steroid-responsive dermatoses, in general, is uncertain. So, in present investigation chromatographic methods were developing use RP-HPLC for estimation of Desoximetasone in bulk and in cream formulation and method validation according to ICH guidelines. The main objective of this study was to develop a simple and reproducible method for desoximetasone by Reverse Phase High Performance Liquid Chromatography (RP-HPLC). In this work the desoximetasone separation was carried out by using C18 cosmosile column (250mmx4.6mm particle size 5µm). By using 0.1% orthrophosphoric acid pH adjusted up to 3 at uv detection of 240nm.The mobile phase was used at various ratio for gradient elution the ratio of mobile phase was 20:80 v/v. Methanol and water used for mobile phase and flow rate was being set at 1mL/min. The linearity of proposed method was found in range of r =0.9989. Statistically validation parameters such as linearity, accuracy, precision, LOD and LOQ were checked. Keywords: Desoximetasone, RP-HPLC, Method validation.