scholarly journals Proposed Model of Neutral Temperature Equation for Adaptive Thermal Comfort in Student Flats Units in the Tropics

2021 ◽  
Vol 9 (2) ◽  
pp. 477-492
Author(s):  
Samsuddin Samsuddin ◽  
Ramli Rahim ◽  
Baharuddin Hamzah ◽  
Rosady Mulyadi
2011 ◽  
Vol 243-249 ◽  
pp. 5013-5016
Author(s):  
Yu Hui Di ◽  
Zhan Bo Wang ◽  
Li Duan Wang

For the study of human thermal sensation in Xi'an and adaptive thermal comfort situation, the measurement of environmental parameters and questionnaires as the way to analyze and explore the indoor and outdoor weather conditions, clothing thermal resistance, thermal sensation and so on. This paper studies human thermal sensation within the civil construction and thermal neutral temperature relationship changes with the seasons. The results showed that: the study of adaptive thermal comfort, human neutral temperature and outdoor ambient temperature has a strong correlation, the resulting models in Xi'an.


Energies ◽  
2021 ◽  
Vol 14 (15) ◽  
pp. 4530
Author(s):  
Youcef Bouzidi ◽  
Zoubayre El Akili ◽  
Antoine Gademer ◽  
Nacef Tazi ◽  
Adil Chahboun

This paper investigates adaptive thermal comfort during summer in medical residences that are located in the French city of Troyes and managed by the Association of Parents of Disabled Children (APEI). Thermal comfort in these buildings is evaluated using subjective measurements and objective physical parameters. The thermal sensations of respondents were determined by questionnaires, while thermal comfort was estimated using the predicted mean vote (PMV) model. Indoor environmental parameters (relative humidity, mean radiant temperature, air temperature, and air velocity) were measured using a thermal environment sensor during the summer period in July and August 2018. A good correlation was found between operative temperature, mean radiant temperature, and PMV. The neutral temperature was determined by linear regression analysis of the operative temperature and Fanger’s PMV model. The obtained neutral temperature is 23.7 °C. Based on the datasets and questionnaires, the adaptive coefficient α representing patients’ capacity to adapt to heat was found to be 1.261. A strong correlation was also observed between the sequential thermal index n(t) and the adaptive temperature. Finally, a new empirical model of adaptive temperature was developed using the data collected from a longitudinal survey in four residential buildings of APEI in summer, and the obtained adaptive temperature is 25.0 °C with upper and lower limits of 24.7 °C and 25.4 °C.


2016 ◽  
Vol 216 ◽  
pp. 655-661 ◽  
Author(s):  
Aiman Albatayneh ◽  
Dariusz Alterman ◽  
Adrian Page ◽  
Behdad Moghtaderi

2021 ◽  
Vol 13 (7) ◽  
pp. 3614
Author(s):  
Zeyad Amin Al-Absi ◽  
Mohd Isa Mohd Hafizal ◽  
Mazran Ismail ◽  
Azhar Ghazali

Building sector is associated with high energy consumption and greenhouse gas emissions, which contribute to climate change. Sustainable development emphasizes any actions to reduce climate change and its effect. In Malaysia, half of the energy utilized in buildings goes towards building cooling. Thermal comfort studies and adaptive thermal comfort models reflect the high comfort temperatures for Malaysians in naturally conditioned buildings, which make it possible to tackle the difference between buildings’ indoor temperature and the required comfort temperature by using proper passive measures. This study investigates the effectiveness of building’s retrofitting with phase change materials (PCMs) as a passive cooling technology to improve the indoor thermal environment for more comfortable conditions. PCM sheets were numerically investigated below the internal finishing of the walls. The investigation involved an optimization study for the PCMs transition temperatures and quantities. The results showed significant improvement in the indoor thermal environment, especially when using lower transition temperatures and higher quantities of PCMs. Therefore, the monthly thermal discomfort time has decreased completely, while the thermal comfort time has increased to as high as 98%. The PCM was effective year-round and the optimum performance for the investigated conditions was achieved when using 18mm layer of PCM27-26.


Energies ◽  
2021 ◽  
Vol 14 (21) ◽  
pp. 7427
Author(s):  
Hermawan Hermawan ◽  
Jozef Švajlenka

Passive thermal comfort has been widely used to test the thermal performance of a building. The science of active thermal comfort is important to be connected with the science of architecture. The currently developing active thermal comfort is adaptive thermal comfort. Vernacular houses are believed to be able to create thermal comfort for the inhabitants. The present study seeks to analyze the connection between the architectural elements of vernacular houses and adaptive thermal comfort. A mixed method was applied. A quantitative approach was used in the measurement of variables of climate, while a qualitative methodology was employed in an interview on thermal sensations. The connection between architectural elements and adaptive thermal comfort was analyzed by considering the correlation among architectural features, the analysis results of thermal comfort, and the Olgyay and psychrometric diagrams. At the beginning of the rainy season, residents of exposed stone houses had the highest comfortable percentage of 31%. In the middle of the rainy season, the highest percentage of comfort was obtained by residents of exposed brick and wooden houses on the beach at 39%. The lowest comfortable percentage experienced by residents of exposed stone houses at the beginning of the dry season was 0%. The beginning of the dry season in mountainous areas has air temperatures that are too low, making residents uncomfortable. The study results demonstrate that adaptive thermal comfort is related to using a room for adaptation to create thermal comfort for the inhabitants.


Sign in / Sign up

Export Citation Format

Share Document