scholarly journals In Vivo μMRI-Based Finite Element and Morphological Analyses of Tibial Trabecular Bone in Eugonadal and Hypogonadal Men Before and After Testosterone Treatment

2008 ◽  
Vol 23 (9) ◽  
pp. 1426-1434 ◽  
Author(s):  
X Henry Zhang ◽  
X Sherry Liu ◽  
Branimir Vasilic ◽  
Felix W Wehrli ◽  
Maria Benito ◽  
...  
2001 ◽  
Vol 123 (6) ◽  
pp. 607-612 ◽  
Author(s):  
John T. Koontz ◽  
Guillaume T. Charras ◽  
Robert E. Guldberg

A finite element method to simulate the formation of an interconnected trabecular bone microstructure oriented with respect to applied in vivo mechanical forces is introduced and quantitatively compared to experimental data from a hydraulic bone chamber implant model. Randomly located 45 μm mineralized nodules were used as the initial condition for the model simulations to represent an early stage of intramembranous bone formation. Boundary conditions were applied consistent with the mechanical environment provided by the in vivo bone chamber model. A two-dimensional repair simulation algorithm that incorporated strain energy density (SED), SED gradient, principal strain, or principal strain gradient as the local objective criterion was utilized to simulate the formation of an oriented trabecular bone microstructure. The simulation solutions were convergent, unique, and relatively insensitive to the assumed initial distribution of mineralized nodules. Model predictions of trabecular bone morphology and anisotropy were quantitatively compared to experimental results. All simulations produced structures that qualitatively resembled oriented trabecular bone. However, only simulations utilizing a gradient objective criterion yielded results quantitatively similar to in vivo observations. This simulation approach coupled with an experimental model that delivers controlled in vivo mechanical stimuli can be utilized to study the relationship between physical factors and microstructural adaptation during bone repair.


2013 ◽  
Vol 40 (5) ◽  
pp. 052303 ◽  
Author(s):  
Ning Zhang ◽  
Jeremy F. Magland ◽  
Chamith S. Rajapakse ◽  
Yusuf A. Bhagat ◽  
Felix W. Wehrli

2002 ◽  
Vol 13 (1) ◽  
pp. 6-17 ◽  
Author(s):  
B. van Rietbergen ◽  
G. von Ingersleben ◽  
C. Chesnut ◽  
B. MacDonald ◽  
H. K. Genant ◽  
...  

1994 ◽  
Vol 71 (04) ◽  
pp. 499-506 ◽  
Author(s):  
Mark W C Hatton ◽  
Bonnie Ross-Ouellet

SummaryThe behavior of 125I-labeled recombinant hirudin towards the uninjured and de-endothelialized rabbit aorta wall has been studied in vitro and in vivo to determine its usefulness as an indicator of thrombin activity associated with the aorta wall. Thrombin adsorbed to either sulfopropyl-Sephadex or heparin-Sepharose bound >95% of 125I-r-hirudin and the complex remained bound to the matrix. Binding of 125I-r-hirudin to the exposed aorta subendothelium (intima-media) in vitro was increased substantially if the tissue was pre-treated with thrombin; the quantity of l25I-r-hirudin bound to the de-endothelialized intima-media (i.e. balloon-injured in vitro) correlated positively with the quantity of bound 131I-thrombin (p <0.01). Aortas balloon-injured in vivo were measured for thrombin release from, and binding of 125I-r-hirudin to, the de-endothelialized intimal surface in vitro; 125I-r-hirudin binding correlated with the amount of active thrombin released (p <0.001). Uptake of 125I-r-hirudin by the aorta wall in vivo was proportional to the uptake of 131I-fibrinogen (as an indicator of thrombin activity) before and after balloon injury. After 30 min in the circulation, specific 125I-r-hirudin binding to the uninjured and de-endo- thelialized (at 1.5 h after injury) aorta wall was equivalent to 3.4 (± 2.5) and 25.6 (±18.1) fmol of thrombin/cm2 of intima-media, respectively. Possibly, only hirudin-accessible, glycosaminoglycan-bound thrombin is measured in this way.


1997 ◽  
Vol 78 (04) ◽  
pp. 1202-1208 ◽  
Author(s):  
Marianne Kjalke ◽  
Julie A Oliver ◽  
Dougald M Monroe ◽  
Maureane Hoffman ◽  
Mirella Ezban ◽  
...  

SummaryActive site-inactivated factor VIIa has potential as an antithrombotic agent. The effects of D-Phe-L-Phe-L-Arg-chloromethyl ketone-treated factor VIla (FFR-FVIIa) were evaluated in a cell-based system mimicking in vivo initiation of coagulation. FFR-FVIIa inhibited platelet activation (as measured by expression of P-selectin) and subsequent large-scale thrombin generation in a dose-dependent manner with IC50 values of 1.4 ± 0.8 nM (n = 8) and 0.9 ± 0.7 nM (n = 7), respectively. Kd for factor VIIa binding to monocytes ki for FFR-FVIIa competing with factor VIIa were similar (11.4 ± 0.8 pM and 10.6 ± 1.1 pM, respectively), showing that FFR-FVIIa binds to tissue factor in the tenase complex with the same affinity as factor VIIa. Using platelets from volunteers before and after ingestion of aspirin (1.3 g), there were no significant differences in the IC50 values of FFR-FVIIa [after aspirin ingestion, the IC50 values were 1.7 ± 0.9 nM (n = 8) for P-selectin expression, p = 0.37, and 1.4 ± 1.3 nM (n = 7) for thrombin generation, p = 0.38]. This shows that aspirin treatment of platelets does not influence the inhibition of tissue factor-initiated coagulation by FFR-FVIIa, probably because thrombin activation of platelets is not entirely dependent upon expression of thromboxane A2.


1999 ◽  
Vol 19 (04) ◽  
pp. 168-175 ◽  
Author(s):  
M. Weippert-Kretschmer ◽  
V. Kretschmer

SummaryPerioperative bleeding complications due to disorders of primary haemostasis are often underestimated. Routine determination of primary haemostasis is still problematic. The in vivo bleeding time (BT) shows low sensitivity and high variability. In this contribution the results and experiences with the IVBT having been obtained in various studies and during 10 years of routine use are reported. Patients and Methods: Blood donors before and after ASA ingestion, patients with thrombocytopenia as well as congenital and acquired platelet function disorders. Monitoring of desmopressin efficacy. IVBT with Thrombostat 4000 (tests with CaCl2 = TST-CaCl2 and ADP = TST-ADP) and PFA-100 (test cartridges with epinephrine = PFA-EPI and ADP = PFA-ADP). Results and Conclusions: IVBT becomes abnormal with platelet counts <100,000/μl. With platelet counts <50,000/μl the results are mostly outside the methodical range. IVBT proved clearly superior to BT in von Willebrand syndrome (vWS). All 16 patients with vWS were detected by PFA-EPI, whereas with BT 7 of 10 patients with moderate and 1 of 6 patients with mild forms of vWS were spotted. The majority of acquired and congenital platelet function disorders with relevant bleeding tendency were detectable by IVBT. Sometimes diagnostic problems arose in case of storage pool defect. Four to 12 h after ingestion of a single dose of 100 mg ASA the TST-CaCl2 became abnormal in all cases, the PFA-EPI only in 80%. However, the ASA sensitivity of TST-CaCl2 proved even too high when looking for perioperative bleeding complications in an urological study. Therefore, the lower ASS sensitivity of the PFA-100 seems to be rather advantageous for the estimation of a real bleeding risk. The good efficacy of desmopressin in the majority of cases with mild thrombocytopenia, congenital and acquired platelet function disorders and even ASS-induced platelet dysfunction could be proven by means of the IVBT. Thus IVBT may help to increase the reliability of the therapy. However, the IVBT with the PFA-100 is not yet fully developed. Nevertheless, routine use can be recommended when special methodical guidelines are followed.


2020 ◽  
Vol 1 (12) ◽  
pp. 40-42
Author(s):  
F. Yu. Daurova ◽  
D. I. Tomaeva ◽  
S. V. Podkopaeva ◽  
Yu. A. Taptun

Relevance: the reason for the development of complications in endodontic treatment is poor-quality instrumental treatment root canals.Aims: a study of the animicrobial action and clinical efficacy of high-frequency monopolar diathermocoagulation in the treatment of chronic forms of pulpitis.Materials and methods: 102 patients with various chronic forms of pulpitis were divided into three groups of 34 patients each. In the first two groups, high-frequency monopolar diathermocoagulation was used in endodontic treatment in different modes. In the third group, endodontic treatment was carried out without the use of diathermocoagulation (comparison group). The root canal microflora in chronic pulpitis in vivo was studied twice-before and after diathermocoagulation.Results: it was established that high-frequency monopolar diathermocoagulation in the effect mode is 3, power is 4 (4.1 W) and effect is 4, power is 4 (5.4 W) with an exposure time of 3 seconds, it has a pronounced antibacterial effect on all presented pathogenic microflora obtained from the root canals of the teeth.


Sign in / Sign up

Export Citation Format

Share Document