scholarly journals A high-throughput microsphere-based immunoassay of anti-SARS-CoV-2 IgM testing for COVID-19 diagnostics

PLoS ONE ◽  
2021 ◽  
Vol 16 (9) ◽  
pp. e0248444
Author(s):  
Dayu Zhang ◽  
Tianyang Xu ◽  
Eric Chu ◽  
Aiguo Zhang ◽  
Jinwei Du ◽  
...  

The pandemic of novel coronavirus disease COVID-19 is rapidly expanding across the world. A positive result of antibody tests suggests that the individual has potentially been exposed to SARS-CoV-2, thus allowing to identify asymptomatic infections and determine the seroprevalence in a given population. The aim of this study was to evaluate the performances of a newly developed high throughput immunoassay for anti-SARS-CoV-2 IgM antibody detection on the Luminex MAGPIX platform. Clinical agreement studies were performed in 42 COVID-19 patient serum samples and 162 negative donor serum/plasma samples. Positive percent agreement (PPA) was 42.86% (95% CI: 9.90% to 81.59%), 71.43% (95% CI: 29.04% to 96.33%), and 28.57% (95% CI: 13.22% to 48.67%) for samples collected on 0–7 days, 8–14 days, and 2–8 weeks from symptom onset, respectively. Negative Percent Agreement (NPA) was 97.53% (95% CI: 93.80% to 99.32%). There was no cross-reactivity with the SARS-CoV-2 IgG antibody. Hemoglobin (200 mg/dL), bilirubin (2 mg/dL), triglyceride (250 mg/dL) and EDTA (10 mM) showed no significant interfering effect on this assay. In conclusion, an anti-SARS-CoV-2 IgM antibody assay with high sensitivity and specificity has been developed. With the high throughput, this assay will speed up the anti-SARS-CoV-2 IgM testing.

2021 ◽  
Author(s):  
Dayu Zhang ◽  
Tianyang Xu ◽  
Eric Chu ◽  
Aiguo Zhang ◽  
Jinwei Du ◽  
...  

ABSTRACTThe pandemic of novel coronavirus disease COVID-19 is rapidly expanding across the world. A positive result of antibody tests suggests that the individual has potentially been exposed to SARS-CoV-2, thus allowing to identify asymptomatic infections and determine the seroprevalence in a given population. The aim of this study was to evaluate the performances of a newly developed high throughput immunoassay for anti-SARS-CoV-2 IgM antibody detection on the Luminex MAGPIX platform. Clinical agreement studies were performed in 42 COVID-19 patient serum samples and 162 negative donor serum/plasma samples. Positive percent agreement (PPA) was 42.86% (95% CI: 9.90% to 81.59%), 71.43% (95% CI: 29.04% to 96.33%), and 28.57% (95% CI: 13.22% to 48.67%) for samples collected on 0-7 days, 8-14 days, and 2-8 weeks from symptom onset, respectively. Negative Percent Agreement (NPA) was 97.53% (95% CI: 93.80% to 99.32%). There was no cross-reactivity with the SARS-CoV-2 IgG antibody Hemoglobin (200 mg/dL), bilirubin (2 mg/dL), triglyceride (250 mg/dL) and EDTA (10 mM) showed no significant interfering effect on this assay. In conclusion, an anti-SARS-CoV-2 IgM antibody assay with high sensitivity and specificity has been developed. With the high throughput, this assay will speed up the anti-SARS-CoV-2 IgM testing.


2020 ◽  
Author(s):  
Jinwei Du ◽  
Eric Chu ◽  
Dayu Zhang ◽  
Chuanyi M Lu ◽  
Aiguo Zhang ◽  
...  

Background: Serology tests for detecting the antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can identify previous infection and help to confirm the presence of current infection. Objective: The aim of this study was to evaluate the performances of a newly developed high throughput immunoassay for anti-SARS-CoV-2 IgG antibody detection. Results: Clinical agreement studies were performed in 77 COVID-19 patient serum samples and 226 negative donor serum/plasma samples. Positive percent agreement (PPA) was 42.86% (95% CI: 9.90% to 81.59%), 55.56% (95% CI: 21.20% to 86.30%), and 96.72% (95% CI: 88.65% to 99.60%) for samples collected on 0-7 days, 8-14 days, and ≥15 days from symptom onset, respectively. Negative Percent Agreement (NPA) was 98.23% (95% CI: 95.53% to 99.52%). No cross-reactivity was observed to patient samples positive for IgG antibodies against the following pathogens: HIV, HAV, HBV, RSV, CMV, EBV, Rubella, Influenza A, and Influenza B. Hemoglobin (200 mg/dL), bilirubin (2 mg/dL) and EDTA (10 mM) showed no significant interfering effect on this assay. Conclusion: An anti-SARS-CoV-2 IgG antibody assay with high sensitivity and specificity has been developed. With the high throughput, this assay will speed up the anti-SARS-CoV-2 IgG testing.


2020 ◽  
Vol 58 (6) ◽  
pp. 774-778 ◽  
Author(s):  
Joshua Malo ◽  
Eric Holbrook ◽  
Tirdad Zangeneh ◽  
Chris Strawter ◽  
Eyal Oren ◽  
...  

Abstract Coccidioidomycosis is a common cause of community-acquired pneumonia in endemic areas of the southwestern United States. Clinical presentations range from self-limited disease to severe, disseminated disease. As such, early and accurate diagnosis is essential to ensure appropriate treatment and monitoring. Currently available diagnostic testing has variable accuracy, particularly in certain patient populations, and new tests may offer improved accuracy for the diagnosis of coccidioidomycosis. Serum samples from patients with coccidioidomycosis and controls were tested for immunoglobulin G (IgG) and immunoglobulin M (IgM) antibodies using the MVista Coccidioides antibody detection EIA and two commonly used commercial enzyme immunoassay (EIA) kits: the IMMY Omega EIA and the Meridian Premier EIA. The sensitivity of the IgG antibody detection was 87.4% using the MVista test compared to 46.6% for IMMY and 70.9% for Meridian. The sensitivity for IgM antibody detection was 61.2% for the MVista test, 22.3% for IMMY and 29.1% for Meridian. For IgG antibody detection, specificity was 90% for the MVista EIA, 94.6% for IMMY, 96.4% for Meridian. For IgM antibody detection, specificity was 95.3% for the MVista test 98.2% for IMMY and 99.1% for Meridian. The MVista Coccidioides antibody EIA offers improved sensitivity, including among high-risk patient populations, for the detection of IgG and IgM antibodies in comparison to other currently available EIAs.


2020 ◽  
Author(s):  
Tiancheng Liu ◽  
Jessica Hsiung ◽  
Su Zhao ◽  
Jessica Kost ◽  
Deepika Sreedhar ◽  
...  

AbstractThe outbreak and rapid spread of SARS-CoV-2 virus has led to a dire global pandemic with millions of people infected and ~ 400,000 deaths thus far. Highly accurate detection of antibodies for COVID-19 is an indispensable part of the effort to combat the pandemic1,2. Here we developed two-plex antibody detection against SARS-CoV-2 spike proteins3 (the S1 subunit and receptor binding domain RBD) in human serum and saliva on a near-infrared nano-plasmonic gold (pGOLD) platform4–8. By testing nearly 600 serum samples, pGOLD COVID-19 assay achieved ~ 99.78 % specificity for detecting both IgG and IgM with 100 % sensitivity in sera collected > 14 days post disease symptom onset, with zero cross-reactivity to other diseases. Two-plex correlation analysis revealed higher binding of serum IgM to RBD than to S1. IgG antibody avidity toward multiple antigens were measured, shedding light on antibody maturation in COVID-19 patients and affording a powerful tool for differentiating recent from remote infections and identifying re-infection by SARS-CoV-2. Just as important, due to high analytical sensitivity, the pGOLD COVID-19 assay detected minute amounts of antibodies in human saliva, offering the first non-invasive detection of SARS-CoV-2 antibodies.


2019 ◽  
Vol 57 (5) ◽  
Author(s):  
Marcílio Jorge Fumagalli ◽  
William Marciel de Souza ◽  
Marília Farignoli Romeiro ◽  
Michell Charles de Souza Costa ◽  
Renata Dezengrini Slhessarenko ◽  
...  

ABSTRACT Mayaro virus (MAYV) is a neglected arthropod-borne virus (arbovirus) antigenically clustered into the Semliki Forest complex group of Alphavirus genus (Togaviridae family), maintained in an unclear zoonotic cycle involving mosquitoes from Haemagogus genus as the main vector. The genome is composed of a positive single-stranded RNA of 11.5 kb in length, which contains two genes that encode four nonstructural (nsP1 to nsP4) and five structural (C, E3, E2, 6K, and E1) proteins. In the present study, we have developed an enzyme-linked immunosorbent assay (ELISA) using as antigen the recombinant envelope protein 2 of MAYV produced in an Escherichia coli system (rE2-MAYV ELISAs). A panel of 68 human serum samples from suspected arboviral cases was analyzed and titrated for anti-MAYV IgM and IgG antibody detection. The rE2-MAYV ELISA detected 33.8% (23/68) IgG-positive samples, demonstrating 100% sensitivity and 78.95% specificity compared to the MAYV-specific 50% plaque reduction neutralization assay. In addition, the positive MAYV-neutralizing samples showed high titers of detection by rE2-MAYV ELISA, suggesting a highly sensitive test. The rE2-MAYV ELISA also detected 42.5% (29/68) IgM-positive samples, of which 13.8% (4/29) presented high-avidity interactions with rE2-MAYV. Cross-reactivity was observed with Chikungunya virus (CHIKV)-specific murine antibody sample but not with CHIKV-specific human and other Alphavirus murine antibodies. In short, we have developed a rapid, simple, specific, and sensitive MAYV rE2-ELISA, and our preliminary results show its potential applicability to diagnosis of MAYV infections.


2020 ◽  
Vol 58 (8) ◽  
Author(s):  
Elitza S. Theel ◽  
Julie Harring ◽  
Heather Hilgart ◽  
Dane Granger

ABSTRACT The role of serologic testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), in both the clinical and public health settings, will continue to evolve as we gain increasing insight into our immune response to the virus. Here, we evaluated four high-throughput serologic tests for detection of anti-SARS-CoV-2 IgG antibodies, from Abbott Laboratories (Abbott Park, IL), Epitope Diagnostics, Inc. (San Diego, CA), Euroimmun (Lubeck, Germany), and Ortho-Clinical Diagnostics (Rochester, NY), using a panel of serially collected serum samples (n = 224) from 56 patients with confirmed coronavirus disease 2019 (COVID-19), healthy donor sera from 2018, and a cross-reactivity serum panel collected in early 2020. The sensitivities of the Abbott, Epitope, Euroimmun, and Ortho-Clinical IgG assays in convalescent-phase serum samples collected more than 14 days post-symptom onset or post-initial positive reverse transcriptase PCR (RT-PCR) result were 92.9% (78/84), 88.1% (74/84), 97.6% (82/84), and 98.8% (83/84), respectively. Among unique convalescent patients, sensitivities of the Abbott, Epitope, Euroimmun, and Ortho-Clinical anti-SARS-CoV-2 IgG assays were 97.3% (36/37), 73% (27/37), 94.6% (35/37), and 97.3% (36/37), respectively. Overall assay specificity/positive predictive values based on a 5% prevalence rate were 99.6%/92.8%, 99.6%/90.6%, 98.0%/71.2%, and 99.6%/92.5%, respectively, for the Abbott, Epitope, Euroimmun, and Ortho-Clinical IgG assays. In conclusion, we show high sensitivity in convalescent-phase sera and high specificity for the Abbott, Euroimmun, and Ortho-Clinical anti-SARS-CoV-2 IgG assays. With the unprecedented influx of commercially available serologic tests for detection of antibodies against SARS-CoV-2, it remains imperative that laboratories thoroughly evaluate such assays for accuracy prior to implementation.


2016 ◽  
Vol 54 (12) ◽  
pp. 3034-3042 ◽  
Author(s):  
O. Villard ◽  
B. Cimon ◽  
C. L'Ollivier ◽  
H. Fricker-Hidalgo ◽  
N. Godineau ◽  
...  

Toxoplasmosis, a benign infection, is asymptomatic or paucisymptomatic in over 80% of cases, except in immunocompetent patients suffering from ocular toxoplasmosis or in immunocompromised patients with opportunistic or congenital toxoplasmosis. Diagnosis is based mainly on serology testing. Thus, we compared the performance of the nine most commonly used commercial automated or semiautomated immunoassays for IgG and IgMToxoplasma gondiiantibody detection, that is, the Advia Centaur, Architect, AxSYM, Elecsys, Enzygnost, Liaison, Platelia, VIDAS, and VIDIA assays. The assays were conducted on four panels of serum samples derived during routine testing from patients with an interfering disease and who exhibited a low IgG antibody level in one of two clinical settings, namely, acute or chronic toxoplasmosis. As a result, IgG sensitivities ranged from 97.1% to 100%, and IgG specificities ranged from 99.5% to 100%. For IgG quantification, strong differences in IgG titers (expressed in IU/ml) were noted depending on the assay used. IgM sensitivities ranged from 65% to 97.9%, and IgM specificities ranged from 92.6% to 100%. For defining the best serological strategies to be implemented, it appears crucial to compare the diagnostic performance of the different tests with respect to their specificity and sensitivity in detecting the presence of IgG and IgM antibodies.


2020 ◽  
Author(s):  
Beatriz Araujo Oliveira ◽  
Lea Campos de Oliveira ◽  
Franciane Mendes de Oliveira ◽  
Geovana Maria Pereira ◽  
Regina Maia de Souza ◽  
...  

AbstractBackgroundCOVID-19 disease (Coronavirus disease 2019) caused by SARS-CoV-2 (Severe acute respiratory syndrome coronavirus 2) is widespread worldwide, affecting more than 11 million people globally (July 6th, 2020). Diagnostic techniques have been studied in order to contain the pandemic. Immunochromatographic (IC) assays are feasible and low cost alternative for monitoring the spread of COVID-19 in the population.MethodsHere we evaluate the sensitivity and specificity of eleven different immunochromatographic tests in 98 serum samples from confirmed cases of COVID-19 through RT-PCR and 100 negative serum samples from blood donors collected in February 2019. Considering the endemic situation of Dengue in Brazil, we also evaluated the cross-reactivity with Dengue using 20 serum samples from patients with confirmed diagnosis for Dengue collected in early 2019 through four different tests.ResultsOur results demonstrated agreement between immunochromatographic assays and RT-PCR, especially after 10 days since the onset of symptoms. The evaluation of IgG and IgM antibodies combined demonstrated a strong level of agreement (0.85) of IC assays and RT-PCR. It was observed cross-reactivity between Dengue and COVID-19 using four different IC assays for COVID-19 diagnosis. The specificity of IC assays to detected COVID-19 IgM antibodies using Dengue serum samples varied from 80% to 85%; the specificity of IgG detection was 100% and total antibody was 95%.ConclusionsWe found high sensitivity, specificity and good agreement of IC assays, especially after 10 days onset of symptoms. However, we detected cross-reactivity between Dengue and COVID-19 mainly with IgM antibodies demonstrating the need for better studies about diagnostic techniques for these diseases.HighlightsImmunochromatographic assays demonstrated high sensitivity and specificity and good agreement with the gold-standard RT-PCR;Increase in sensitivity and specificity of assays using samples collected after the 10th day of symptoms;Cross-reaction with Dengue serology in evaluation of IgM.


2021 ◽  
Vol 12 ◽  
Author(s):  
Bochao Liu ◽  
Ze Wu ◽  
Chaolan Liang ◽  
Jinhui Lu ◽  
Jinfeng Li ◽  
...  

Since December 2019, a novel coronavirus (SARS-CoV-2) has resulted in a global pandemic of coronavirus disease (COVID-19). Although viral nucleic acid test (NAT) has been applied predominantly to detect SARS-CoV-2 RNA for confirmation diagnosis of COVID-19, an urgent need for alternative, rapid, and sensitive immunoassays is required for primary screening of virus. In this study, we developed a smartphone-based nanozyme-linked immunosorbent assay (SP-NLISA) for detecting the specific nucleocapsid phosphoprotein (NP) of SARS-CoV-2 in 37 serum samples from 20 COVID-19 patients who were diagnosed by NAT previously. By using SP-NLISA, 28/37 (75.7%) serum samples were detected for NP antigens and no cross-reactivity with blood donors’ control samples collected from different areas of China. In a control assay using the conventional enzyme-linked immunosorbent assay (ELISA), only 7/37 (18.91%) serum samples were detected for NP antigens and no cross-reactivity with control samples. SP-NLISA could be used for rapid detection of SARS-CoV-2 NP antigen in primary screening of SARS-CoV-2 infected individuals.


1985 ◽  
Vol 31 (7) ◽  
pp. 1131-1134 ◽  
Author(s):  
Y C Tseng ◽  
K D Burman ◽  
J R Baker ◽  
L Wartofsky

Abstract In this enzyme-linked immunoassay for human thyrotropin (TSH) in unextracted serum we use 96-well immunoenzymometric assay plates, first coated with polyclonal antibody to TSH, then incubated with the serum samples and reacted with mouse monoclonal antibody to human TSH. After incubation with alkaline phosphatase-labeled antibody against mouse IgG, disodium p-nitrophenyl phosphate is added and the color change is measured spectrophotometrically. Assay sensitivity is 0.1 milli-int. unit/L. Cross reactivity with lutropin, follitropin, or choriogonadotropin was negligible. TSH concentrations ranged from 0.4 to 4.1 milli-int. units/L in 43 normal subjects (mean 2.0, SD 1.0), and were uniformly less than 0.3 milli-int. unit/L in 23 patients with hyperthyroidism. Features which make this assay advantageous to the clinical laboratory include ease of set-up, ability to assay many samples at a time, high sensitivity, rapid turnaround time (8 h), and absence of requirements for radioactive materials.


Sign in / Sign up

Export Citation Format

Share Document