scholarly journals Performance Characteristics of Four High-Throughput Immunoassays for Detection of IgG Antibodies against SARS-CoV-2

2020 ◽  
Vol 58 (8) ◽  
Author(s):  
Elitza S. Theel ◽  
Julie Harring ◽  
Heather Hilgart ◽  
Dane Granger

ABSTRACT The role of serologic testing for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), in both the clinical and public health settings, will continue to evolve as we gain increasing insight into our immune response to the virus. Here, we evaluated four high-throughput serologic tests for detection of anti-SARS-CoV-2 IgG antibodies, from Abbott Laboratories (Abbott Park, IL), Epitope Diagnostics, Inc. (San Diego, CA), Euroimmun (Lubeck, Germany), and Ortho-Clinical Diagnostics (Rochester, NY), using a panel of serially collected serum samples (n = 224) from 56 patients with confirmed coronavirus disease 2019 (COVID-19), healthy donor sera from 2018, and a cross-reactivity serum panel collected in early 2020. The sensitivities of the Abbott, Epitope, Euroimmun, and Ortho-Clinical IgG assays in convalescent-phase serum samples collected more than 14 days post-symptom onset or post-initial positive reverse transcriptase PCR (RT-PCR) result were 92.9% (78/84), 88.1% (74/84), 97.6% (82/84), and 98.8% (83/84), respectively. Among unique convalescent patients, sensitivities of the Abbott, Epitope, Euroimmun, and Ortho-Clinical anti-SARS-CoV-2 IgG assays were 97.3% (36/37), 73% (27/37), 94.6% (35/37), and 97.3% (36/37), respectively. Overall assay specificity/positive predictive values based on a 5% prevalence rate were 99.6%/92.8%, 99.6%/90.6%, 98.0%/71.2%, and 99.6%/92.5%, respectively, for the Abbott, Epitope, Euroimmun, and Ortho-Clinical IgG assays. In conclusion, we show high sensitivity in convalescent-phase sera and high specificity for the Abbott, Euroimmun, and Ortho-Clinical anti-SARS-CoV-2 IgG assays. With the unprecedented influx of commercially available serologic tests for detection of antibodies against SARS-CoV-2, it remains imperative that laboratories thoroughly evaluate such assays for accuracy prior to implementation.

PLoS ONE ◽  
2021 ◽  
Vol 16 (9) ◽  
pp. e0248444
Author(s):  
Dayu Zhang ◽  
Tianyang Xu ◽  
Eric Chu ◽  
Aiguo Zhang ◽  
Jinwei Du ◽  
...  

The pandemic of novel coronavirus disease COVID-19 is rapidly expanding across the world. A positive result of antibody tests suggests that the individual has potentially been exposed to SARS-CoV-2, thus allowing to identify asymptomatic infections and determine the seroprevalence in a given population. The aim of this study was to evaluate the performances of a newly developed high throughput immunoassay for anti-SARS-CoV-2 IgM antibody detection on the Luminex MAGPIX platform. Clinical agreement studies were performed in 42 COVID-19 patient serum samples and 162 negative donor serum/plasma samples. Positive percent agreement (PPA) was 42.86% (95% CI: 9.90% to 81.59%), 71.43% (95% CI: 29.04% to 96.33%), and 28.57% (95% CI: 13.22% to 48.67%) for samples collected on 0–7 days, 8–14 days, and 2–8 weeks from symptom onset, respectively. Negative Percent Agreement (NPA) was 97.53% (95% CI: 93.80% to 99.32%). There was no cross-reactivity with the SARS-CoV-2 IgG antibody. Hemoglobin (200 mg/dL), bilirubin (2 mg/dL), triglyceride (250 mg/dL) and EDTA (10 mM) showed no significant interfering effect on this assay. In conclusion, an anti-SARS-CoV-2 IgM antibody assay with high sensitivity and specificity has been developed. With the high throughput, this assay will speed up the anti-SARS-CoV-2 IgM testing.


2021 ◽  
Author(s):  
Dayu Zhang ◽  
Tianyang Xu ◽  
Eric Chu ◽  
Aiguo Zhang ◽  
Jinwei Du ◽  
...  

ABSTRACTThe pandemic of novel coronavirus disease COVID-19 is rapidly expanding across the world. A positive result of antibody tests suggests that the individual has potentially been exposed to SARS-CoV-2, thus allowing to identify asymptomatic infections and determine the seroprevalence in a given population. The aim of this study was to evaluate the performances of a newly developed high throughput immunoassay for anti-SARS-CoV-2 IgM antibody detection on the Luminex MAGPIX platform. Clinical agreement studies were performed in 42 COVID-19 patient serum samples and 162 negative donor serum/plasma samples. Positive percent agreement (PPA) was 42.86% (95% CI: 9.90% to 81.59%), 71.43% (95% CI: 29.04% to 96.33%), and 28.57% (95% CI: 13.22% to 48.67%) for samples collected on 0-7 days, 8-14 days, and 2-8 weeks from symptom onset, respectively. Negative Percent Agreement (NPA) was 97.53% (95% CI: 93.80% to 99.32%). There was no cross-reactivity with the SARS-CoV-2 IgG antibody Hemoglobin (200 mg/dL), bilirubin (2 mg/dL), triglyceride (250 mg/dL) and EDTA (10 mM) showed no significant interfering effect on this assay. In conclusion, an anti-SARS-CoV-2 IgM antibody assay with high sensitivity and specificity has been developed. With the high throughput, this assay will speed up the anti-SARS-CoV-2 IgM testing.


2020 ◽  
Author(s):  
Jinwei Du ◽  
Eric Chu ◽  
Dayu Zhang ◽  
Chuanyi M Lu ◽  
Aiguo Zhang ◽  
...  

Background: Serology tests for detecting the antibodies to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can identify previous infection and help to confirm the presence of current infection. Objective: The aim of this study was to evaluate the performances of a newly developed high throughput immunoassay for anti-SARS-CoV-2 IgG antibody detection. Results: Clinical agreement studies were performed in 77 COVID-19 patient serum samples and 226 negative donor serum/plasma samples. Positive percent agreement (PPA) was 42.86% (95% CI: 9.90% to 81.59%), 55.56% (95% CI: 21.20% to 86.30%), and 96.72% (95% CI: 88.65% to 99.60%) for samples collected on 0-7 days, 8-14 days, and ≥15 days from symptom onset, respectively. Negative Percent Agreement (NPA) was 98.23% (95% CI: 95.53% to 99.52%). No cross-reactivity was observed to patient samples positive for IgG antibodies against the following pathogens: HIV, HAV, HBV, RSV, CMV, EBV, Rubella, Influenza A, and Influenza B. Hemoglobin (200 mg/dL), bilirubin (2 mg/dL) and EDTA (10 mM) showed no significant interfering effect on this assay. Conclusion: An anti-SARS-CoV-2 IgG antibody assay with high sensitivity and specificity has been developed. With the high throughput, this assay will speed up the anti-SARS-CoV-2 IgG testing.


2003 ◽  
Vol 17 (2) ◽  
pp. 142-146 ◽  
Author(s):  
José Freitas Siqueira Júnior ◽  
Isabela das Neves Rôças

The aim of this study was to describe a 16S rDNA-based nested polymerase chain reaction (nPCR) assay to investigate the occurrence of Campylobacter gracilis in oral infections. Samples were collected from ten infected root canals, ten cases of acute periradicular abscesses and eight cases of adult marginal periodontitis. DNA extracted from the samples was initially amplified using universal 16S rDNA primers. A second round of amplification used the first PCR products to detect C. gracilis using oligonucleotide primers designed from species-specific 16S rDNA signature sequences. The nPCR assay used in this study showed a detection limit of 10 C. gracilis cells and no cross-reactivity was observed with nontarget bacteria. C. gracilis was detected in the three types of oral infections investigated - 4/10 infected root canals; 2/10 acute periradicular abscesses; and 1/8 subgingival specimens from adult periodontitis. The method proposed in this study showed both high sensitivity and high specificity to directly detect C. gracilis in samples from root canal infections, abscesses, and subgingival plaque. Our findings confirmed that C. gracilis may be a member of the microbiota associated with distinct oral infections, and its specific role in such diseases requires further clarification.


2020 ◽  
Author(s):  
Beatriz Araujo Oliveira ◽  
Lea Campos de Oliveira ◽  
Franciane Mendes de Oliveira ◽  
Geovana Maria Pereira ◽  
Regina Maia de Souza ◽  
...  

AbstractBackgroundCOVID-19 disease (Coronavirus disease 2019) caused by SARS-CoV-2 (Severe acute respiratory syndrome coronavirus 2) is widespread worldwide, affecting more than 11 million people globally (July 6th, 2020). Diagnostic techniques have been studied in order to contain the pandemic. Immunochromatographic (IC) assays are feasible and low cost alternative for monitoring the spread of COVID-19 in the population.MethodsHere we evaluate the sensitivity and specificity of eleven different immunochromatographic tests in 98 serum samples from confirmed cases of COVID-19 through RT-PCR and 100 negative serum samples from blood donors collected in February 2019. Considering the endemic situation of Dengue in Brazil, we also evaluated the cross-reactivity with Dengue using 20 serum samples from patients with confirmed diagnosis for Dengue collected in early 2019 through four different tests.ResultsOur results demonstrated agreement between immunochromatographic assays and RT-PCR, especially after 10 days since the onset of symptoms. The evaluation of IgG and IgM antibodies combined demonstrated a strong level of agreement (0.85) of IC assays and RT-PCR. It was observed cross-reactivity between Dengue and COVID-19 using four different IC assays for COVID-19 diagnosis. The specificity of IC assays to detected COVID-19 IgM antibodies using Dengue serum samples varied from 80% to 85%; the specificity of IgG detection was 100% and total antibody was 95%.ConclusionsWe found high sensitivity, specificity and good agreement of IC assays, especially after 10 days onset of symptoms. However, we detected cross-reactivity between Dengue and COVID-19 mainly with IgM antibodies demonstrating the need for better studies about diagnostic techniques for these diseases.HighlightsImmunochromatographic assays demonstrated high sensitivity and specificity and good agreement with the gold-standard RT-PCR;Increase in sensitivity and specificity of assays using samples collected after the 10th day of symptoms;Cross-reaction with Dengue serology in evaluation of IgM.


2020 ◽  
Vol 10 (3) ◽  
pp. 165-171
Author(s):  
Ingrid E. Pereira ◽  
Kyssia P. Silva ◽  
Laura M. Menegati ◽  
Aimara C. Pinheiro ◽  
Elaine A. O. Assunção ◽  
...  

AbstractControl of canine visceral leishmaniasis (CVL), a major zoonotic disease in Brazil and many other tropical and subtropical countries, remains difficult as an accurate and reliable diagnosis is still missing. In endemic regions, infected dogs are the main parasitic reservoir host of human Visceral leishmaniasis (VL) infection. Vaccination of dogs against Leishmania infection constitutes an important strategy to prevent or to better control CVL, thus, a serological test that can discriminate between antibodies induced by immunization versus infection is highly desirable in order to improve and simplify diagnosis. Here, four recombinant proteins were evaluated for their ability to detect and differentiate between dogs that are infected with Leishmania or have been immunized with the anti-Leishmania vaccine Leish-Tec®. Receiver operating characteristic (ROC) curve analysis of the four Leishmania-specific IgG ELISA revealed superior performance of rK28, followed by rKLO8, rK39 and rLb6H. The rK28-based ELISA revealed not only the best accuracy against CVL, but also the lowest cross-reactivity with sera from Leish-Tec® immunized dogs. Our data show that the rK28-based ELISA is highly suitable for CVL screening as it shows high sensitivity with simultaneous low cross-reactivity. Further, the high specificity of the rKLO8 indicates its suitability for the confirmation of CVL diagnosis.


Author(s):  
Rahmah Noordin ◽  
Emelia Osman ◽  
Nor Suhada Anuar ◽  
Nor Mustaiqazah Juri ◽  
Anizah Rahumatullah ◽  
...  

A lateral flow rapid test for strongyloidiasis will greatly facilitate the control and elimination of the disease. Previously SsRapid™ prototype rapid test showed high diagnostic specificity to detect Strongyloides infection, determined using non-Strongyloides sera negative by IgG-ELISAs. Since high specificity is crucial before a test is used for public health control activities, further validation of its specificity is needed. Also, it needs to be ascertained whether non-Strongyloides sera positive by IgG-ELISAs and SsRapid are truly positive for Strongyloides or are cases of cross-reactivity. We performed 84 rapid tests (two types of dipsticks and cassettes) using 34 serum samples. They were divided into four groups based on Strongyloides infection and coinfection with other parasites and the availability of recombinant proteins and rapid tests for the latter. Sera was adsorbed using polystyrene microspheres beads separately coated with four recombinant parasite proteins. The small sample size is a limitation of this study; however, the overall results showed that the sera adsorption procedure was successful, and the SsRapid test is specific.


2013 ◽  
Vol 21 (1) ◽  
pp. 96-106 ◽  
Author(s):  
Lourena E. Costa ◽  
Mayara I. S. Lima ◽  
Miguel A. Chávez-Fumagalli ◽  
Daniel Menezes-Souza ◽  
Vivian T. Martins ◽  
...  

ABSTRACTVisceral leishmaniasis (VL) is a zoonotic disease that is endemic to Brazil, where dogs are the main domestic parasite reservoirs, and the percentages of infected dogs living in regions where canine VL (CVL) is endemic have ranged from 10% to 62%. Despite technological advances, some problems have been reported with CVL serodiagnosis. The present study describes a sequential subtractive selection through phage display technology from polyclonal antibodies of negative and positive sera that resulted in the identification of potential bacteriophage-fused peptides that were highly sensitive and specific to antibodies of CVL. A negative selection was performed in which phage clones were adhered to purified IgGs from healthy andTrypanosoma cruzi-infected dogs to eliminate cross-reactive phages. The remaining supernatant nonadhered phages were submitted to positive selection against IgG from the blood serum of dogs that were infected withLeishmania infantum. Phage clones that adhered to purified IgGs from the CVL-infected serum samples were selected. Eighteen clones were identified and their reactivities tested by a phage enzyme-linked immunosorbent assay (phage-ELISA) against the serum samples from infected dogs (n= 31) compared to those from vaccinated dogs (n= 21), experimentally infected dogs with cross-reactive parasites (n= 23), and healthy controls (n= 17). Eight clones presented sensitivity, specificity, and positive and negative predictive values of 100%, and they showed no cross-reactivity withT. cruzi- orEhrlichia canis-infected dogs or with dogs vaccinated with two different commercial CVL vaccines in Brazil. Our study identified eight mimotopes ofL. infantumantigens with 100% accuracy for CVL serodiagnosis. The use of these mimotopes by phage-ELISA proved to be an excellent assay that was reproducible, simple, fast, and inexpensive, and it can be applied in CVL-monitoring programs.


1985 ◽  
Vol 31 (7) ◽  
pp. 1131-1134 ◽  
Author(s):  
Y C Tseng ◽  
K D Burman ◽  
J R Baker ◽  
L Wartofsky

Abstract In this enzyme-linked immunoassay for human thyrotropin (TSH) in unextracted serum we use 96-well immunoenzymometric assay plates, first coated with polyclonal antibody to TSH, then incubated with the serum samples and reacted with mouse monoclonal antibody to human TSH. After incubation with alkaline phosphatase-labeled antibody against mouse IgG, disodium p-nitrophenyl phosphate is added and the color change is measured spectrophotometrically. Assay sensitivity is 0.1 milli-int. unit/L. Cross reactivity with lutropin, follitropin, or choriogonadotropin was negligible. TSH concentrations ranged from 0.4 to 4.1 milli-int. units/L in 43 normal subjects (mean 2.0, SD 1.0), and were uniformly less than 0.3 milli-int. unit/L in 23 patients with hyperthyroidism. Features which make this assay advantageous to the clinical laboratory include ease of set-up, ability to assay many samples at a time, high sensitivity, rapid turnaround time (8 h), and absence of requirements for radioactive materials.


2002 ◽  
Vol 9 (2) ◽  
pp. 374-377 ◽  
Author(s):  
Daniela A. Cunha ◽  
Roseli M. Zancopé-Oliveira ◽  
M. Sueli ◽  
S. Felipe ◽  
Silvia M. Salem-Izacc ◽  
...  

ABSTRACT The complete coding cDNA of HSP60 from Paracoccidioides brasiliensis was overexpressed in an Escherichia coli host to produce high levels of recombinant protein. The protein was purified by affinity chromatography. A total of 169 human serum samples were tested for reactivity by Western blot analysis with the purified HSP60 recombinant protein. Immunoblots indicated that the recombinant P. brasiliensis HSP60 was recognized by antibodies in 72 of 75 sera from paracoccidioidomycosis patients. No cross-reactivity was detected with individual sera from patients with aspergillosis, sporotrichosis, cryptococcosis, and tuberculosis. Reactivity to HSP60 was observed in sera from 9.52% of control healthy individuals and 11.5% of patients with histoplasmosis. The high sensitivity and specificity (97.3 and 92.5%, respectively) for HSP60 suggested that the recombinant protein can be used singly or in association with other recombinant antigens to detect antibody responses in P. brasiliensis-infected patients.


Sign in / Sign up

Export Citation Format

Share Document