scholarly journals Mechanical Circulatory Support to Treat Pulmonary Embolism: Venoarterial Extracorporeal Membrane Oxygenation and Right Ventricular Assist Devices

2020 ◽  
Vol 47 (3) ◽  
pp. 202-206
Author(s):  
Aneil Bhalla ◽  
Robert Attaran

Mechanical circulatory support may help patients with massive pulmonary embolism who are not candidates for systemic thrombolysis, pulmonary embolectomy, or catheter-directed therapy, or in whom these established interventions have failed. Little published literature covers this topic, which led us to compare outcomes of patients whose massive pulmonary embolism was managed with the use of venoarterial extracorporeal membrane oxygenation (VA-ECMO) or a right ventricular assist device (RVAD). We searched the medical literature from January 1990 through September 2018 for reports of adults hospitalized for massive or high-risk pulmonary embolism complicated by hemodynamic instability, and who underwent VA-ECMO therapy or RVAD placement. Primary outcomes included weaning from mechanical circulatory support and discharge from the hospital. We found 16 reports that included 181 patients (164 VA-ECMO and 17 RVAD). All RVAD recipients were successfully weaned from support, as were 122 (74%) of the VA-ECMO patients. Sixteen (94%) of the RVAD patients were discharged from the hospital, as were 120 (73%) of the VA-ECMO patients. Of note, the 8 RVAD patients who had an Impella RP System were all weaned and discharged. For patients with massive pulmonary embolism who are not candidates for conventional interventions or whose conditions are refractory, mechanical circulatory support in the form of RVAD placement or ECMO may be considered. Larger comparative studies are needed.

2019 ◽  
pp. 088506661989454
Author(s):  
Aniket S. Rali ◽  
Jonathan Chandler ◽  
Andrew Sauer ◽  
Michael A. Solomon ◽  
Zubair Shah

Cardiogenic shock (CS) portends an extremely high mortality of nearly 50% during index hospitalization. Prompt diagnoses of CS, its underlying etiology, and efficient implementation of treatment modalities, including mechanical circulatory support (MCS), are critical especially in light of such high predicted mortality. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) provides the most comprehensive cardiopulmonary support in critically ill patients and hence has seen a steady increase in its utilization over the past decade. Hence, a good understanding of VA-ECMO, its role in treatment of CS, especially when compared with other temporary MCS devices, and its complications are vital for any critical care cardiologist. Our review of VA-ECMO aims to provide the same.


Perfusion ◽  
2021 ◽  
pp. 026765912110339
Author(s):  
Shek-yin Au ◽  
Ka-man Fong ◽  
Chun-Fung Sunny Tsang ◽  
Ka-Chun Alan Chan ◽  
Chi Yuen Wong ◽  
...  

Introduction: The intra-aortic balloon pump (IABP) and Impella are left ventricular unloading devices with peripheral venoarterial extracorporeal membrane oxygenation (VA-ECMO) in place and later serve as bridging therapy when VA-ECMO is terminated. We aimed to determine the potential differences in clinical outcomes and rate of complications between the two combinations of mechanical circulatory support. Methods: This was a retrospective, single institutional cohort study conducted in the intensive care unit (ICU) of Queen Elizabeth Hospital, Hong Kong. Inclusion criteria included all patients aged ⩾18 years, who had VA-ECMO support, and who had left ventricular unloading by either IABP or Impella between January 1, 2018 and October 31, 2020. Patients <18 years old, with central VA-ECMO, who did not require left ventricular unloading, or who underwent surgical venting procedures were excluded. The primary outcome was ECMO duration. Secondary outcomes included length of stay (LOS) in the ICU, hospital LOS, mortality, and complication rate. Results: Fifty-two patients with ECMO + IABP and 14 patients with ECMO + Impella were recruited. No statistically significant difference was observed in terms of ECMO duration (2.5 vs 4.6 days, p = 0.147), ICU LOS (7.7 vs 10.8 days, p = 0.367), and hospital LOS (14.8 vs 16.5 days, p = 0.556) between the two groups. No statistically significant difference was observed in the ECMO, ICU, and hospital mortalities between the two groups. Specific complications related to the ECMO and Impella combination were also noted. Conclusions: Impella was not shown to offer a statistically significant clinical benefit compared with IABP in conjunction with ECMO. Clinicians should be aware of the specific complications of using Impella.


Critical Care ◽  
2021 ◽  
Vol 25 (1) ◽  
Author(s):  
Ryan Ruiyang Ling ◽  
Kollengode Ramanathan ◽  
Wynne Hsing Poon ◽  
Chuen Seng Tan ◽  
Nicolas Brechot ◽  
...  

Abstract Background While recommended by international societal guidelines in the paediatric population, the use of venoarterial extracorporeal membrane oxygenation (VA ECMO) as mechanical circulatory support for refractory septic shock in adults is controversial. We aimed to characterise the outcomes of adults with septic shock requiring VA ECMO, and identify factors associated with survival. Methods We searched Pubmed, Embase, Scopus and Cochrane databases from inception until 1st June 2021, and included all relevant publications reporting on > 5 adult patients requiring VA ECMO for septic shock. Study quality and certainty in evidence were assessed using the appropriate Joanna Briggs Institute checklist, and the Grading of Recommendations, Assessment, Development and Evaluations (GRADE) approach, respectively. The primary outcome was survival to hospital discharge, and secondary outcomes included intensive care unit length of stay, duration of ECMO support, complications while on ECMO, and sources of sepsis. Random-effects meta-analysis (DerSimonian and Laird) were conducted. Data synthesis We included 14 observational studies with 468 patients in the meta-analysis. Pooled survival was 36.4% (95% confidence interval [CI]: 23.6%–50.1%). Survival among patients with left ventricular ejection fraction (LVEF) < 20% (62.0%, 95%-CI: 51.6%–72.0%) was significantly higher than those with LVEF > 35% (32.1%, 95%-CI: 8.69%–60.7%, p = 0.05). Survival reported in studies from Asia (19.5%, 95%-CI: 13.0%–26.8%) was notably lower than those from Europe (61.0%, 95%-CI: 48.4%–73.0%) and North America (45.5%, 95%-CI: 16.7%–75.8%). GRADE assessment indicated high certainty of evidence for pooled survival. Conclusions When treated with VA ECMO, the majority of patients with septic shock and severe sepsis-induced myocardial depression survive. However, VA ECMO has poor outcomes in adults with septic shock without severe left ventricular depression. VA ECMO may be a viable treatment option in carefully selected adult patients with refractory septic shock.


2021 ◽  
Vol 10 (4) ◽  
pp. 747
Author(s):  
Georgios Chatzis ◽  
Styliani Syntila ◽  
Birgit Markus ◽  
Holger Ahrens ◽  
Nikolaos Patsalis ◽  
...  

Since mechanical circulatory support (MCS) devices have become integral component in the therapy of refractory cardiogenic shock (RCS), we identified 67 patients in biventricular support with Impella and venoarterial Extracorporeal Membrane Oxygenation (VA-ECMO) for RCS between February 2013 and December 2019 and evaluated the risk factors of mortality in this setting. Mean age was 61.07 ± 10.7 and 54 (80.6%) patients were male. Main cause of RCS was acute myocardial infarction (AMI) (74.6%), while 44 (65.7%) were resuscitated prior to admission. The mean Simplified Acute Physiology Score II (SAPS II) and Sequential Organ Failure Assessment Score (SOFA) score on admission was 73.54 ± 16.03 and 12.25 ± 2.71, respectively, corresponding to an expected mortality of higher than 80%. Vasopressor doses and lactate levels were significantly decreased within 72 h on biventricular support (p < 0.05 for both). Overall, 17 (25.4%) patients were discharged to cardiac rehabilitation and 5 patients (7.5%) were bridged successfully to ventricular assist device implantation, leading to a total of 32.8% survival on hospital discharge. The 6-month survival was 31.3%. Lactate > 6 mmol/L, vasoactive score > 100 and pH < 7.26 on initiation of biventricular support, as well as Charlson comorbity index > 3 and prior resuscitation were independent predictors of survival. In conclusion, biventricular support with Impella and VA-ECMO in patients with RCS is feasible and efficient leading to a better survival than predicted through traditional risk scores, mainly via significant hemodynamic improvement and reduction in lactate levels.


2018 ◽  
Vol 45 (3) ◽  
pp. 182-185 ◽  
Author(s):  
Mohamed Shokr ◽  
Ahmed Rashed ◽  
Ashraf Mostafa ◽  
Tamam Mohamad ◽  
Theodore Schreiber ◽  
...  

Right ventricular failure secondary to pulmonary embolism is associated with morbidity and death. The Impella RP System has often been used for percutaneous mechanical circulatory support in patients with right ventricular failure from other causes, including myocardial infarction, cardiac surgery, and left ventricular assist device implantation. We report 2 cases of massive pulmonary embolism in which combined Impella RP use and ultrasound-assisted catheter-directed thrombolysis effectively treated shock caused by right ventricular failure and contributed to successful outcomes. To our knowledge, only one other patient with this indication had been treated with the Impella RP device.


Perfusion ◽  
2017 ◽  
Vol 33 (4) ◽  
pp. 323-325 ◽  
Author(s):  
Aditya Badheka ◽  
Pradeep Bangalore Prakash ◽  
Veerajalandhar Allareddy

Background: Acute massive pulmonary embolism (PE) is a very rare condition in children. We report the successful use of veno-arterial extracorporeal membrane oxygenation (VA ECMO) as a lifesaving modality in a child with acute massive PE. Case presentation: A nine-year-old female with spinal muscular atrophy type 1, chronic respiratory failure with tracheostomy and ventilator dependence presented with tachypnea and hypoxia. She had recent coiling of her pulmonary arterio-venous malformation. A chest computerized tomography scan showed massive bilateral PE. Urgent catheter-directed thrombolysis failed. She was placed on VA-ECMO with stabilization of hemodynamics. She underwent surgical thrombo-embolectomy followed by weaning of ECMO support. Discussion: The use of VA ECMO supported the cardio-respiratory status and perfusion to facilitate surgical embolectomy.


2007 ◽  
Vol 17 (S4) ◽  
pp. 104-115 ◽  
Author(s):  
David S. Cooper ◽  
Jeffrey P. Jacobs ◽  
Lisa Moore ◽  
Arabela Stock ◽  
J. William Gaynor ◽  
...  

AbstractMechanical circulatory support is an invaluable tool in the care of children with severe refractory cardiac and or pulmonary failure. Two forms of mechanical circulatory support are currently available to neonates, infants, and smaller children, namely extracorporeal membrane oxygenation and use of a ventricular assist device, with each technique having unique advantages and disadvantages. The intra-aortic balloon pump is a third form of mechanical support that has been successfully used in larger children, adolescents, and adults, but has limited applicability in smaller children. In this review, we discuss the current experiences with extracorporeal membrane oxygenation and ventricular assist devices in children with cardiac disease.A variety of forms of mechanical circulatory support are available for children with cardiopulmonary dysfunction refractory to conventional management. These devices require extensive resources, both human and economic. Extracorporeal membrane oxygenation can be effectively used in a variety of settings to provide support to critically-ill patients with cardiac disease. Careful selection of patients and timing of intervention remains challenging. Special consideration should be given to children with cardiac disease with regard to anatomy, physiology, cannulation, and circuit management. Even though exciting progress is being made in the development of ventricular assist devices for long-term mechanical support in children, extracorporeal membrane oxygenation remains the mainstay of mechanical circulatory support in children with complex anatomy, particularly those needing rapid resuscitation and those with a functionally univentricular circulation.As the familiarity and experience with extracorporeal membrane oxygenation has grown, new indications have evolved, including emergent resuscitation. This utilization has been termed extracorporeal cardiopulmonary resuscitation. The literature supporting emergent cardiopulmonary support is mounting. Reasonable survival rates have been achieved after initiation of support during active compressions of the chest following in-hospital cardiac arrest. Due to the limitations of conventional circuits for extracorporeal membrane oxygenation, some centres have developed novel systems for rapid cardiopulmonary support.Many centres previously considered a functionally univentricular circulation to be a contraindication to extracorporeal membrane oxygenation, but improved results have been achieved recently with this complex subset of patients. The registry of the Extracorporeal Life Support Organization recently reported the outcome of extracorporeal life support used in neonates for cardiac indications from 1996 to 2000. Of the 740 neonates who were placed on extracorporeal life support for cardiac indications, 118 had hypoplastic left heart syndrome. There was no significant difference in survival between these patients and those with other defects. It is now common to use extracorporeal membrane oxygenation to support patients with a functionally univentricular circulation, and reasonable survival rates are to be expected.Although extracorporeal membrane oxygenation has become a standard of care for many paediatric centres, its use is limited to those patients who require only short-term cardiopulmonary support. Mechanical ventricular assist devices have become standard therapy for adults with cardiac failure refractory to maximal medical management. Several devices are readily available in the United States of America for adults, but there are fewer options available to children. Over the last few years, substantial progress has been made in paediatric mechanical support. Ventricular assist devices are being used with increasing frequency in children with cardiac failure refractory to medical therapy for primary treatment as a long-term bridge to recovery or transplantation. The paracorporeal, pneumatic, pulsatile “Berlin Heart” ventricular assist device is being used with increasing frequency in Europe and North America to provide univentricular and biventricular support. With this device, a patient can be maintained on mechanical circulatory support while extubated, being mobilized, and feeding by mouth.Mechanical circulatory support should be anticipated, and every attempt must be made to initiate support “urgently” rather than “emergently”, before the presence of dysfunction of end organs or circulatory collapse. In an emergency, these patients can be resuscitated with extracorporeal membrane oxygenation and subsequently transitioned to a long-term ventricular assist device after a period of stability.