scholarly journals Changes in The Content of Biodegradable Organic Matter in Tap Water in The City of Częstochowa / Zmiany Zawartości Biodegradowalnej Materii Organicznej w Wodzie Wodociagowej Dla Miasta Częstochowy

2016 ◽  
Vol 20 (1) ◽  
pp. 89-100
Author(s):  
Klaudia Rakocz ◽  
Agata Rosińska

Abstract This paper presents research aimed at the assessment of biodegradable organic carbon content changes (BDOC) during water disinfection process. The water samples examined in the research came from intakes, pumping stations at treatment plants situated in the Silesia district and water consumers. The examined water was underground water. One water sample was disinfected by sodium sub chloride while the other one by ozone. BDOC was determined using the Joret method, which involves observation of dissolved organic carbon (DOC) decrease in the examined water. The research has shown that BDOC content fluctuates at every stage of the treatment process and distribution of the examined water. Another analyzed parameter was biological stability of water.

Water ◽  
2018 ◽  
Vol 10 (12) ◽  
pp. 1764 ◽  
Author(s):  
Andżelika Domoń ◽  
Dorota Papciak ◽  
Barbara Tchórzewska-Cieślak ◽  
Katarzyna Pietrucha-Urbanik

This article presents results of research which aimed to assess the impact of biofiltration processing on the biological stability of water. Effectiveness of biogenic substances removal (C, N, P) and bacteriological quality of water after the biofiltration process were discussed. The research was carried out on a semi-technical scale on natural underground water rich in organic compounds. A filter with a biologically active carbon (BAC) bed was used for the research. Despite the low water temperature of between 9–12 °C, there was a high efficiency of organic matter removal—33–70%. The number of mesophilic and psychrophilic bacteria in the water before and after the biofiltration process was comparable (0–23 CFU/mL) and met the requirements for drinking water. No E. coli was detected in the water samples. The biological material washed out of the filter bed did not cause deterioration of water quality which proved that the operating parameters of the biofilters were properly chosen, i.e., contact time of 30 min, filtration speed up to 3 m/h. Reduction of the content of nutrients in the treated water limits the risk of microbial growth and thus the emergence of biological growth in the distribution system.


2017 ◽  
Vol 82 (6) ◽  
pp. 739-754 ◽  
Author(s):  
Danica Mitrovic ◽  
Natasa Djokovic ◽  
Dragana Zivotic ◽  
Achim Bechtel ◽  
Olga Cvetkovic ◽  
...  

Four lignite lithotypes (matrix coal, xylite-rich coal, mixture of matrix and mineral-rich coal and mixture of matrix and xylite-rich coal), originating from the Kovin deposit, were investigated in detail. The paper was aimed to determine the main maceral, biomarker and isotopic (?13C) characteristics of investigated lithotypes. Based on these results the sources and depositional environment of organic matter in 4 lithotypes were established. These samples were also used as substrates for investigation of the influence of diagenetic alteration on ?13C signatures of biomarkers, as well as for assessment of the most convenient utilization for each lithotype. The investigated lithotypes differ in accordance with the composition of huminite macerals. Xylite-rich coal notably distinguishes from other lithotypes beacuse of the highest content of conifer resins vs. epicuticular waxes. The mixture of matrix and mineral-rich coal is characterised by the greatest contribution of algae and fungi and the most intense methanotrophic activity at the time of deposition. In all coal lithotypes diagenetic aromatisation influenced isotopic composition of individual biomarkers. Xylite-rich coal has the poorest grindability properties. However, this coal lithotype is the most suitable for fluidized bed gasification, whereas the mixture of matrix and mineral-rich coal has the lowest applicability for this process. The calorific value decreases in order: xylite-rich coal > matrix coal > mixture of matrix and xylite-rich coal > mixture of matrix and mineral-rich coal. The increase of organic carbon content and calorific value is controlled by the increase of contribution of wood vegetation vs. herbaceous peat-forming plants, as well as by stability of water table during peatification.


2018 ◽  
Vol 3 (1) ◽  
Author(s):  
Nusa Idaman Said

Water disinfection means the removal, deactivation or killing of pathogenic microorganisms. Microorganisms are destroyed or deactivated, resulting in termination of growth and reproduction. When microorganisms are not removed from drinking water, drinking water usage will cause people to fall ill. Chemical inactivation of microbiological contamination in natural or untreated water is usually one of the final steps to reduce pathogenic microorganisms in drinking water. Combinations of water purification steps (oxidation, coagulation, settling, disinfection, and filtration) cause (drinking) water to be safe after production. As an extra measure many countries apply a second disinfection step at the end of the water purification process, in order to protect the water from microbiological contamination in the water distribution system. Usually one uses a different kind of disinfectant from the one earlier in the process, during this disinfection process. The secondary disinfection makes sure that bacteria will not multiply in the water during distribution. This paper describes several technique of disinfection process for drinking water treatment. Disinfection can be attained by means of physical or chemical disinfectants. The agents also remove organic contaminants from water, which serve as nutrients or shelters for microorganisms. Disinfectants should not only kill microorganisms. Disinfectants must also have a residual effect, which means that they remain active in the water after disinfection. For chemical disinfection of water the following disinfectants can be used such as Chlorine (Cl2),  Hypo chlorite (OCl-), Chloramines, Chlorine dioxide (ClO2), Ozone (O3), Hydrogen peroxide etch. For physical disinfection of water the following disinfectants can be used is Ultraviolet light (UV). Every technique has its specific advantages and and disadvantages its own application area sucs as environmentally friendly, disinfection byproducts, effectivity, investment, operational costs etc. Kata Kunci : Disinfeksi, bakteria, virus, air minum, khlor, hip khlorit, khloramine, khlor dioksida, ozon, UV.


2021 ◽  
Vol 24 ◽  
pp. e00367
Author(s):  
Patrick Filippi ◽  
Stephen R. Cattle ◽  
Matthew J. Pringle ◽  
Thomas F.A. Bishop

2021 ◽  
Vol 13 (15) ◽  
pp. 8332
Author(s):  
Snežana Jakšić ◽  
Jordana Ninkov ◽  
Stanko Milić ◽  
Jovica Vasin ◽  
Milorad Živanov ◽  
...  

Topography-induced microclimate differences determine the local spatial variation of soil characteristics as topographic factors may play the most essential role in changing the climatic pattern. The aim of this study was to investigate the spatial distribution of soil organic carbon (SOC) with respect to the slope gradient and aspect, and to quantify their influence on SOC within different land use/cover classes. The study area is the Region of Niš in Serbia, which is characterized by complex topography with large variability in the spatial distribution of SOC. Soil samples at 0–30 cm and 30–60 cm were collected from different slope gradients and aspects in each of the three land use/cover classes. The results showed that the slope aspect significantly influenced the spatial distribution of SOC in the forest and vineyard soils, where N- and NW-facing soils had the highest level of organic carbon in the topsoil. There were no similar patterns in the uncultivated land. No significant differences were found in the subsoil. Organic carbon content was higher in the topsoil, regardless of the slope of the terrain. The mean SOC content in forest land decreased with increasing slope, but the difference was not statistically significant. In vineyards and uncultivated land, the SOC content was not predominantly determined by the slope gradient. No significant variations across slope gradients were found for all observed soil properties, except for available phosphorus and potassium. A positive correlation was observed between SOC and total nitrogen, clay, silt, and available phosphorus and potassium, while a negative correlation with coarse sand was detected. The slope aspect in relation to different land use/cover classes could provide an important reference for land management strategies in light of sustainable development.


Author(s):  
Emmanuelle Vaudour ◽  
Cécile Gomez ◽  
Philippe Lagacherie ◽  
Thomas Loiseau ◽  
Nicolas Baghdadi ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document