scholarly journals Ultra-wideband enhancement on mid-infrared fingerprint sensing for 2D materials and analytes of monolayers by a metagrating

Nanophotonics ◽  
2020 ◽  
Vol 9 (9) ◽  
pp. 2927-2935
Author(s):  
Yinong Xie ◽  
Xueying Liu ◽  
Fajun Li ◽  
Jinfeng Zhu ◽  
Naixing Feng

AbstractMid-infrared absorption spectroscopy is a powerful tool to identify analytes by detecting their material fingerprint in a label-free way, but it faces barriers on trace-amount analysis due to the difficulties in enhancing the broadband spectral signals. Here, we propose a sensing scheme based on the angular scanning of polarized light on a dielectric metagrating, and demonstrate it by numerical simulation. This approach not only indicates a series of significant signal enhancement factors over 30 times in an ultra-wide mid-infrared band, but also enables the explicit identification for various analytes, including 2D materials and trace-amount thin film samples. Our method would facilitate mid-infrared sensing for 2D materials and trace-amount analysis, and enable many new applications on non-destructive molecular identification.

2018 ◽  
Author(s):  
Miguel A. Pleitez ◽  
Asrar Ali Khan ◽  
Josefine Reber ◽  
Andriy Chmyrov ◽  
Markus R. Seeger ◽  
...  

We developed mid-infrared optoacoustic microscopy (MiROM), a bond-selective imaging modality that overcomes water/tissue opacity and depth limitations of mid-infrared sensing allowing uncompromised live-cell/thick-tissue mid-infrared microscopy with up to three orders of magnitudehigher sensitivity than other vibrational imaging modalities; such as Raman. We showcase the functional label-free biomolecular imaging capabilities of MiROM by monitoring the spatiotemporal dynamics of lipids and proteins during lipolysis in living adipocytes. Since MiROM, contrary to Ramanmodalities, is not only able to detect lipids and proteins, but also important metabolites such as glucose without the need of labels, here we discuss how MiROM yields novel functional label-free abilities for a broader range of analytical studies in living cells and tissues.


The Analyst ◽  
2017 ◽  
Vol 142 (8) ◽  
pp. 1179-1184 ◽  
Author(s):  
B. Bird ◽  
J. Rowlette

Mid-infrared microscopy is a non-destructive, quantitative and label-free spectroscopic imaging technique that, as a result of recent instrument advancements, is now at the point of enabling high-throughput automated biochemical screening of whole histology samples.


Nanomaterials ◽  
2021 ◽  
Vol 11 (6) ◽  
pp. 1485
Author(s):  
Wei Wang ◽  
Ruikang Zhao ◽  
Shilong Chang ◽  
Jing Li ◽  
Yan Shi ◽  
...  

In this paper, one spin-selected vortex metalens composed of silicon nanobricks is designed and numerically investigated at the mid-infrared band, which can produce vortex beams with different topological charges and achieve different spin lights simultaneously. Another type of spin-independent vortex metalens is also designed, which can focus the vortex beams with the same topological charge at the same position for different spin lights, respectively. Both of the two vortex metalenses can achieve high-efficiency focusing for different spin lights. In addition, the spin-to-orbital angular momentum conversion through the vortex metalens is also discussed in detail. Our work facilitates the establishment of high-efficiency spin-related integrated devices, which is significant for the development of vortex optics and spin optics.


2021 ◽  
Vol 12 (1) ◽  
Author(s):  
Soo-Yeon Cho ◽  
Xun Gong ◽  
Volodymyr B. Koman ◽  
Matthias Kuehne ◽  
Sun Jin Moon ◽  
...  

AbstractNanosensors have proven to be powerful tools to monitor single cells, achieving spatiotemporal precision even at molecular level. However, there has not been way of extending this approach to statistically relevant numbers of living cells. Herein, we design and fabricate nanosensor array in microfluidics that addresses this limitation, creating a Nanosensor Chemical Cytometry (NCC). nIR fluorescent carbon nanotube array is integrated along microfluidic channel through which flowing cells is guided. We can utilize the flowing cell itself as highly informative Gaussian lenses projecting nIR profiles and extract rich information. This unique biophotonic waveguide allows for quantified cross-correlation of biomolecular information with various physical properties and creates label-free chemical cytometer for cellular heterogeneity measurement. As an example, the NCC can profile the immune heterogeneities of human monocyte populations at attomolar sensitivity in completely non-destructive and real-time manner with rate of ~600 cells/hr, highest range demonstrated to date for state-of-the-art chemical cytometry.


2021 ◽  
Vol 119 (14) ◽  
pp. 141109
Author(s):  
Yun Meng ◽  
Dan Li ◽  
Chong Zhang ◽  
Yang Wang ◽  
Robert E. Simpson ◽  
...  

2020 ◽  
Vol 14 ◽  
Author(s):  
Hung Tri Tran ◽  
Esther H. R. Tsai ◽  
Amanda J. Lewis ◽  
Tim Moors ◽  
J. G. J. M. Bol ◽  
...  

Gaining insight to pathologically relevant processes in continuous volumes of unstained brain tissue is important for a better understanding of neurological diseases. Many pathological processes in neurodegenerative disorders affect myelinated axons, which are a critical part of the neuronal circuitry. Cryo ptychographic X-ray computed tomography in the multi-keV energy range is an emerging technology providing phase contrast at high sensitivity, allowing label-free and non-destructive three dimensional imaging of large continuous volumes of tissue, currently spanning up to 400,000 μm3. This aspect makes the technique especially attractive for imaging complex biological material, especially neuronal tissues, in combination with downstream optical or electron microscopy techniques. A further advantage is that dehydration, additional contrast staining, and destructive sectioning/milling are not required for imaging. We have developed a pipeline for cryo ptychographic X-ray tomography of relatively large, hydrated and unstained biological tissue volumes beyond what is typical for the X-ray imaging, using human brain tissue and combining the technique with complementary methods. We present four imaged volumes of a Parkinson’s diseased human brain and five volumes from a non-diseased control human brain using cryo ptychographic X-ray tomography. In both cases, we distinguish neuromelanin-containing neurons, lipid and melanic pigment, blood vessels and red blood cells, and nuclei of other brain cells. In the diseased sample, we observed several swellings containing dense granular material resembling clustered vesicles between the myelin sheaths arising from the cytoplasm of the parent oligodendrocyte, rather than the axoplasm. We further investigated the pathological relevance of such swollen axons in adjacent tissue sections by immunofluorescence microscopy for phosphorylated alpha-synuclein combined with multispectral imaging. Since cryo ptychographic X-ray tomography is non-destructive, the large dataset volumes were used to guide further investigation of such swollen axons by correlative electron microscopy and immunogold labeling post X-ray imaging, a possibility demonstrated for the first time. Interestingly, we find that protein antigenicity and ultrastructure of the tissue are preserved after the X-ray measurement. As many pathological processes in neurodegeneration affect myelinated axons, our work sets an unprecedented foundation for studies addressing axonal integrity and disease-related changes in unstained brain tissues.


Author(s):  
D.D. Stupin

AbstractHere we demonstrate a simple label-free bio-electronic radiation (ultra-violet) hazard detector based on non-destructive electrical impedance spectroscopy technique with a single living cell as a sensing element. Radiation results in wrong cell’s functioning and, as corollary, cell’s membrane distortion. The latter results in impedance shift for the electrode covered by the cell. The additional sensitivity of impedance shift is achieved by the simultaneous usage of the TiN porous electrodes and adaptive filtering for impedance data processing. The main advantage of the proposed sensor with respect to purely physical and/or chemical sensors is high selectivity: it a priory reacts only on the dangerous for living beings radiation.


2021 ◽  
Vol 2125 (1) ◽  
pp. 012006
Author(s):  
Nan Wu ◽  
Chengpo Mu ◽  
Yang He ◽  
Huan Liu ◽  
Taiye Liu

Abstract In order to study the infrared radiation (IR) characteristics of rocket engine plume in the mid infrared band, a calculation model for IR transfer of rocket engine plume was built. The flow field data are calculated by software FLUENT. Based on HITRAN database, the IR characteristic parameters are calculated after spectral line correction. The Line of Sight (LoS) is used to solve the radiation characteristics in the plume flow field, and the IR characteristics distribution of the plume in the mid infrared band is obtained, which agree well with the results from open literature. The method has the advantages of simple model, less parameters and fast calculation speed in this paper.


2017 ◽  
Vol 53 (16) ◽  
pp. 2451-2454 ◽  
Author(s):  
Naresh Kumar ◽  
Marek M. Drozdz ◽  
Haibo Jiang ◽  
Daniela M. Santos ◽  
David J. Vaux

Non-destructive & label-free nanoscale mapping of newly-synthesised phospholipid molecules inside a biological cell is demonstrated using tip-enhanced Raman spectroscopy for the first time.


Sign in / Sign up

Export Citation Format

Share Document