Inorganic Replication: Interpretation of Electron Micrographs

Author(s):  
C. J. Calbick
Keyword(s):  
Author(s):  
J. N. Meador ◽  
C. N. Sun ◽  
H. J. White

The electron microscope is being utilized more and more in clinical laboratories for pathologic diagnosis. One of the major problems in the utilization of the electron microscope for diagnostic purposes is the time element involved. Recent experimentation with rapid embedding has shown that this long phase of the process can be greatly shortened. In rush cases the making of projection slides can be eliminated by taking dark field electron micrographs which show up as a positive ready for use. The major limiting factor for use of dark field micrographs is resolution. However, for conference purposes electron micrographs are usually taken at 2.500X to 8.000X. At these low magnifications the resolution obtained is quite acceptable.


Author(s):  
Glen B. Haydon

Analysis of light optical diffraction patterns produced by electron micrographs can easily lead to much nonsense. Such diffraction patterns are referred to as optical transforms and are compared with transforms produced by a variety of mathematical manipulations. In the use of light optical diffraction patterns to study periodicities in macromolecular ultrastructures, a number of potential pitfalls have been rediscovered. The limitations apply to the formation of the electron micrograph as well as its analysis.(1) The high resolution electron micrograph is itself a complex diffraction pattern resulting from the specimen, its stain, and its supporting substrate. Cowley and Moodie (Proc. Phys. Soc. B, LXX 497, 1957) demonstrated changing image patterns with changes in focus. Similar defocus images have been subjected to further light optical diffraction analysis.


Author(s):  
Godfrey C. Hoskins

The first serious electron microscooic studies of chromosomes accompanied by pictures were by I. Elvers in 1941 and 1943. His prodigious study, from the manufacture of micronets to the development of procedures for interpreting electron micrographs has gone all but unnoticed. The application of todays sophisticated equipment confirms many of the findings he gleaned from interpretation of images distorted by the electron optics of that time. In his figure 18 he notes periodic arrangement of pepsin sensitive “prickles” now called secondary fibers. In his figure 66 precise regularity of arrangement of these fibers can be seen. In his figure 22 he reproduces Siegbahn's first stereoscopic electron micrograph of chromosomes.The two stereoscopic pairs of electron micrographs of a human chromosome presented here were taken with a metallurgical stage on a Phillips EM200. These views are interpreted as providing photographic evidence that primary fibers (1°F) about 1,200Å thick are surrounded by secondary fibers (2°F) arranged in regular intervals of about 2,800Å in this metanhase human chromosome. At the telomere the primary fibers bend back on themselves and entwine through the center of each of each chromatid. The secondary fibers are seen to continue to surround primary fibers at telomeres. Thus at telomeres, secondary fibers present a surface not unlike that of the side of the chromosome, and no more susceptible to the addition of broken elements from other chromosomes.


Author(s):  
R. A. Crowther

The reconstruction of a three-dimensional image of a specimen from a set of electron micrographs reduces, under certain assumptions about the imaging process in the microscope, to the mathematical problem of reconstructing a density distribution from a set of its plane projections.In the absence of noise we can formulate a purely geometrical criterion, which, for a general object, fixes the resolution attainable from a given finite number of views in terms of the size of the object. For simplicity we take the ideal case of projections collected by a series of m equally spaced tilts about a single axis.


Author(s):  
Godfrey C. Hoskins ◽  
Betty B. Hoskins

Metaphase chromosomes from human and mouse cells in vitro are isolated by micrurgy, fixed, and placed on grids for electron microscopy. Interpretations of electron micrographs by current methods indicate the following structural features.Chromosomal spindle fibrils about 200Å thick form fascicles about 600Å thick, wrapped by dense spiraling fibrils (DSF) less than 100Å thick as they near the kinomere. Such a fascicle joins the future daughter kinomere of each metaphase chromatid with those of adjacent non-homologous chromatids to either side. Thus, four fascicles (SF, 1-4) attach to each metaphase kinomere (K). It is thought that fascicles extend from the kinomere poleward, fray out to let chromosomal fibrils act as traction fibrils against polar fibrils, then regroup to join the adjacent kinomere.


Author(s):  
A.-M. Ladhoff ◽  
B.J. Thiele ◽  
Ch. Coutelle ◽  
S. Rosenthal

The suggested precursor-product relationship between the nuclear pre-mRNA and the cytoplasmic mRNA has created increased interest also in the structure of these RNA species. Previously we have been published electron micrographs of individual pre-mRNA molecules from erythroid cells. An intersting observation was the appearance of a contour, probably corresponding to higher ordered structures, on one end of 10 % of the pre-mRNA molecules from erythroid rabbit bone marrow cells (Fig. 1A). A virtual similar contour was observed in molecules of 9S globin mRNA from rabbit reticulocytes (Fig. 1B). A structural transformation in a linear contour occurs if the RNA is heated for 10 min to 90°C in the presence of 80 % formamide. This structural transformation is reversible when the denatured RNA is precipitated and redissolved in 0.2 M ammonium acetate.


Author(s):  
Russell L. Steere

Complementary replicas have revealed the fact that the two common faces observed in electron micrographs of freeze-fracture and freeze-etch specimens are complementary to each other and are thus the new faces of a split membrane rather than the original inner and outer surfaces (1, 2 and personal observations). The big question raised by published electron micrographs is why do we not see depressions in the complementary face opposite membrane-associated particles? Reports have appeared indicating that some depressions do appear but complementarity on such a fine scale has yet to be shown.Dog cardiac muscle was perfused with glutaraldehyde, washed in distilled water, then transferred to 30% glycerol (material furnished by Dr. Joaquim Sommer, Duke Univ., and VA Hospital, Durham, N.C.). Small strips were freeze-fractured in a Denton Vacuum DFE-2 Freeze-Etch Unit with complementary replica tooling. Replicas were cleaned in chromic acid cleaning solution, then washed in 4 changes of distilled water and mounted on opposite sides of the center wire of a Formvar-coated grid.


Author(s):  
Burton B. Silver

Sectioned tissue rarely indicates evidence of what is probably a highly dynamic state of activity in mitochondria which have been reported to undergo a variety of movements such as streaming, divisions and coalescence. Recently, mitochondria from the rat anterior pituitary have been fixed in a variety of configurations which suggest that conformational changes were occurring at the moment of fixation. Pinocytotic-like vacuoles which may be taking in or expelling materials from the surrounding cell medium, appear to be forming in some of the mitochondria. In some cases, pores extend into the matrix of the mitochondria. In other forms, the remains of what seems to be pinched off vacuoles are evident in the mitochondrial interior. Dense materials, resembling secretory droplets, appear at the junction of the pores and the cytoplasm. The droplets are similar to the secretory materials commonly identified in electron micrographs of the anterior pituitary.


Author(s):  
William Krakow

Tilted beam dark-field microscopy has been applied to atomic structure determination in perfect crystals, several synthesized molecules with heavy atcm markers and in the study of displaced atoms in crystals. Interpretation of this information in terms of atom positions and atom correlations is not straightforward. Therefore, calculated dark-field images can be an invaluable aid in image interpretation.


Author(s):  
M. Marko ◽  
A. Leith ◽  
D. Parsons

The use of serial sections and computer-based 3-D reconstruction techniques affords an opportunity not only to visualize the shape and distribution of the structures being studied, but also to determine their volumes and surface areas. Up until now, this has been done using serial ultrathin sections.The serial-section approach differs from the stereo logical methods of Weibel in that it is based on the Information from a set of single, complete cells (or organelles) rather than on a random 2-dimensional sampling of a population of cells. Because of this, it can more easily provide absolute values of volume and surface area, especially for highly-complex structures. It also allows study of individual variation among the cells, and study of structures which occur only infrequently.We have developed a system for 3-D reconstruction of objects from stereo-pair electron micrographs of thick specimens.


Sign in / Sign up

Export Citation Format

Share Document