The Behaviour of High-Rise Building with or without Shear Wall under Different Earthquakes

CONSTRUCTION ◽  
2021 ◽  
Vol 1 (2) ◽  
pp. 93-101
Author(s):  
Saffuan Wan Ahmad ◽  
Muhammad Aimran Amzar Kamarudin ◽  
Wan Aniq Ridhwan Wan Ariffin

On the 5th June 2015, an earthquake hit Ranau, Sabah with a magnitude of 6.0 that caused 18 casualties and several injuries are one of the examples that show Malaysia is not safe from any seismic event. Most of the structure in Malaysia was designed not to include seismic action.  Furthermore, an area that has a high density of population such as in the central region (Klang valley) and several main cities in Malaysia has less available land to build landed housing and uses high-rise apartments as an alternative. High-rise buildings that are normally having problems with soft story mechanisms and plan irregularity which could lead to severe damage when earthquakes happen. This study aims to observe the response of high-rise buildings when under different earthquakes in the presence of shear walls. To achieve this objective two models were modelled and analyzed by using ETABS software, the one with a shear wall and the one with no shear wall. The methods used in this study were the response spectrum method and time-history analysis. In the end, the parameters observed were base shear, story stiffness, story drift, and story displacement. The observations highlighted that the effect of earthquake intensities shows a significant effect. The acquired results indicated that the building with the shear wall is more resistant and strong structures as compared to buildings without shear wall when undergoing seismic analysis.

Author(s):  
Ankur Verma

Abstract: Today, larger part of designs around us are built up concrete cement (RCC) outlined constructions. To forestall harm because of quake there is a need to foster powerful procedure to expand the strength and flexibility of elevated structures. Shear wall are steadier and more pliable and thus can bear more even loads. In this paper, we have proposed a relative report between block facade, shear divider and uncovered casing by using ETABS programming. This review is essentially centered around seismic conduct of G+12 building. The outcomes are talked about as far as base shear, sidelong relocation, story float, story solidness and normal period for every one of the three models. We find that shear wall has least parallel uprooting and least time span when contrasted and block facade and uncovered edge. Likewise, we track down that the shear divider model is more adaptable because of lesser float when contrasted and different models. The upsides of removal and float for shear wall is likewise not as much as block facade since the tallness of the structure increments. Keywords: shear wall, bare frame, Response spectrum, Earthquake, ETABS


2012 ◽  
Vol 39 (8) ◽  
pp. 867-877 ◽  
Author(s):  
Damien Gilles ◽  
Ghyslaine McClure

Structural engineers routinely use rational dynamic analysis methods for the seismic analysis of buildings. In linear analysis based on modal superposition or response spectrum approaches, the overall response of a structure (for instance, base shear or inter-storey drift) is obtained by combining the responses in several vibration modes. These modal responses depend on the input load, but also on the dynamic characteristics of the building, such as its natural periods, mode shapes, and damping. At the design stage, engineers can only predict the natural periods using eigenvalue analysis of structural models or empirical equations provided in building codes. However, once a building is constructed, it is possible to measure more precisely its dynamic properties using a variety of in situ dynamic tests. In this paper, we use ambient motions recorded in 27 reinforced concrete shear wall (RCSW) buildings in Montréal to examine how various empirical models to predict the natural periods of RCSW buildings compare to the periods measured in actual buildings under ambient loading conditions. We show that a model in which the fundamental period of RCSW buildings varies linearly with building height would be a significant improvement over the period equation proposed in the 2010 National Building Code of Canada. Models to predict the natural periods of the first two torsion modes and second sway modes are also presented, along with their uncertainty.


Author(s):  
Harsh Joshi

Abstract: Due to sloping land and high seismically active zones, designing and construction of multistory buildings in hilly regions is always a challenge for structural engineers. This review paper focuses to establish a review study on the Possible Types of building frame configuration in the hilly region and he behavior of Such building frames under seismic loading conditions, and (3) The recent research and developments to make such frames less vulnerable to earthquakes. This paper concludes that the dynamics characteristics of such buildings are significantly different in both horizontal and vertical directions, resulting in the center of mass and center of stiffness having eccentricity at point of action and not vertically aligned for different floors. When such frames are subjected to lateral loads, due to eccentricity it generates torsion in the frame. Most of the studies agree that the buildings resting on slanting ground have higher displacement and base shear compared to buildings resting on plain ground and the shorter column attracts more forces and undergoes damage when subjected to earthquake. Keywords: Building frame configuration, Seismic behavior, Dynamic characteristics, Response spectrum analysis, time history analysis.


Earthquake is an unexpected and expensive disaster for both livelihood and economy. In the modern day construction, there has been a lot of importance to make the structure resistant against lateral loads for multi storied building. Shear walls are an option of lateral load resisting system. The Concept of designing shear wall is to provide building structure with sufficient strength and deformation capacity to sustain the demands imposed by lateral loads with adequate margin of safety. The study focuses on effect of shear wall on R.C. building at different heights. For this purpose five models of different heights 15m, 30m, 45m, 60m and 75m and with different aspect ratios of 1.33, 0.66, 0.44, 0.33 and 0.26 respectively have been considered. All the models were designed for seismic zone V. For analysis purpose response spectrum method of analysis is considered as per IS: 1893-2002. The comparative study has been done for base shear, storey displacement, storey drift and storey stiffness. Utilization of shear walls when placed at corners of the building of low aspect ratio in high rise buildings is more effective compared to the low rise buildings of higher aspect ratio, as it gives the larger base shear and lesser displacement. The storey stiffness and storey drift is greatly improved when shear wall is placed at corners of the building


Author(s):  
Gajagantarao Sai Kumar ◽  
Purushotham Rao ◽  
Partheepan Ganesan

Multi-storey buildings tend to get damaged mainly during earthquake. Seismic analysis is a tool for the estimation of structural response in the process of designing earthquake resistant structures and/or retrofitting vulnerable existing structures. The principle purpose of this work is to analyze and design a building with a shear wall and also to find the appropriate position of shear wall that result in maximum resistance towards lateral forces and minimum displacement of the structure. In this study, a G+7 multi-storey building of 15 m ×20 m in plan area has been chosen and modelled using ETABS. The developed model was validated by solving manually and the results were validated in ETABS. Thereafter, 4 different new plans were modelled in ETABS located in the same earthquake zone area. These plans have shear wall concepts are implemented on the building at four different locations. Seismic, vibration and response spectrum analysis were performed on these structures. Salient parameters such as storey stiffness, storey displacement and storey drift were computed using the ETABS model. These were compared with that of the frame having no shear walls. By comparing the results obtained at different shear wall locations, the best plan with the shear wall having minimum lateral storey displacement and maximum stiffness is suggested for this location.


Seismic analysis of structural systems with floor diaphragms has been a requisite in the recent past. The duty of a structural engineer is to be prudent about the behavior of every structural system adopted. Amongst the structural systems that are adopted world over, diaphragm with rigid and semi-rigid floor plate are adopted widely in the analysis. This research focuses on the backstay effect i.e. podium structural interaction with the tower area and consideration of retaining wall as increment of lateral stiffness as specified in latest tall building code IS6700:2016 for low and high rise structures. In the current study models were prepared with low to high rise storeys with rigid and flexible diaphragms considering backstay diaphragm placing tower at center and corner. The models were subjected to seismic forces; response spectrum along with the combination of the gravity loads. The structural responses like natural periods, base shear, displacement and inter storey drift were also studied.


2020 ◽  
Vol 6 (4) ◽  
pp. 204
Author(s):  
Anas M. Fares

In this study, the influence of soil condition under the isolated and fixed bases is studied by using ETABS 16 software for the high-rise regular building. A regular building with 10 floors is modeled and the results are obtained for story displacements, story shear forces and spectral acceleration according to Uniform Building Code 97 (UBC-97) code. The time history analysis has been performed by using 1999 Izmit earthquake record. 3 types of soil which had different stiffnesses are considered in this study. The results show that the value of base shear increases when the soil stiffness decreases. It also noticed that the spectral acceleration is larger in soft soil condition than that of other soil conditions; and this confirms that the structural response spectrum is associated with the soil condition. In addition, when using base isolated building the drift of lower floors will be larger than that of using base isolated, but in the upper floors the drifts of fixed base building will be larger than that of the isolated base building. Finally, time history method in the seismic design will produce base shear less than that from equivalent static method, so calibration factor for design purpose shall be used.


2006 ◽  
Vol 33 (7) ◽  
pp. 854-871 ◽  
Author(s):  
M Panneton ◽  
P Léger ◽  
R Tremblay

An eight-storey reinforced concrete shear wall building located in Montréal and designed according to the 1995 National Building Code of Canada (NBCC) and the Canadian Standards Association standard CSA-A23.3-94 is studied to evaluate the impact of new requirements for inclusion in new editions of the NBCC and CSA-A23.3. Static and modal analyses were conducted according to the 2005 NBCC (draft 2003) and CSA-A23.3-04 (draft 4) procedures, and three-dimensional dynamic inelastic time history analysis was performed using three earthquake records. The building is braced by four flat shear walls and three cores. Various estimates of the fundamental period of vibration based on empirical expressions presented in the literature or structural models with different stiffness assumptions were examined. The analysis also permitted the study of the displacement and force demand on the lateral load resisting system. It was found that the base shear from the 2005 NBCC is 29% higher than the 1995 NBCC value when code empirical formulae are used for the fundamental period of vibration.Key words: building, shear wall, inelastic seismic response, NBCC, CSA-A23.3 design of concrete structures.


Buildings that rest on sloping ground are different from those that rest on level ground. Buildings located on sloping ground are much more prone to earthquakes because they are, in general, irregular, asymmetrical and tensional. Therefore, the movement of the ground affects them much more. Therefore, there is increased insertion of the shear wall to resist side loading. In this work, the multi-storey building G + 20 is analyzed on slopes of 0o and 24o. For the improvement and analysis of full-filled shear walls, GMT, type L and type C soft soil is used. The structure is analyzed by the response spectrum method and responses such as displacement, ground deviation, period and base slices are evaluated and compared using E-TAB software.


2021 ◽  
Vol 933 (1) ◽  
pp. 012008
Author(s):  
A H Prathama ◽  
M Teguh ◽  
F Saleh

Abstract The growing growth of human activities has led to changes in housing patterns in urban areas. The land crisis in urban areas has made land prices uneconomical, so buildings are designed vertically. One solution to resist earthquakes in multi-story buildings is to add a shear wall structure with the proper profile and layout. Shear wall designs with variations influence the base shear, drift ratio, lateral deflection, and story drift patterns. This study presents the structural response comparison of buildings against variations in the profile and layout of shear walls subjected to earthquake loads. Force Based Design method utilizing the response spectrum approach was adopted in the analysis and carried out using SAP200. Six structural models comprise a frame without shear walls, three L-profile shear walls, two I-profile (straight) shear walls. The simulation results of the overall structural models show that the profile and layout configuration of shear walls in the frame structure of a multi-story building correlates directly to the performance of base shear, drift ratio, and story drift with relatively comparative conditions.


Sign in / Sign up

Export Citation Format

Share Document