scholarly journals Effect of Shear Wall on RC Building of Varying Heights

Earthquake is an unexpected and expensive disaster for both livelihood and economy. In the modern day construction, there has been a lot of importance to make the structure resistant against lateral loads for multi storied building. Shear walls are an option of lateral load resisting system. The Concept of designing shear wall is to provide building structure with sufficient strength and deformation capacity to sustain the demands imposed by lateral loads with adequate margin of safety. The study focuses on effect of shear wall on R.C. building at different heights. For this purpose five models of different heights 15m, 30m, 45m, 60m and 75m and with different aspect ratios of 1.33, 0.66, 0.44, 0.33 and 0.26 respectively have been considered. All the models were designed for seismic zone V. For analysis purpose response spectrum method of analysis is considered as per IS: 1893-2002. The comparative study has been done for base shear, storey displacement, storey drift and storey stiffness. Utilization of shear walls when placed at corners of the building of low aspect ratio in high rise buildings is more effective compared to the low rise buildings of higher aspect ratio, as it gives the larger base shear and lesser displacement. The storey stiffness and storey drift is greatly improved when shear wall is placed at corners of the building

Author(s):  
Eunmi Ryu ◽  
Heesun Kim ◽  
Yeongsoo Shin

AbstractThe purpose of this study was to investigate the thermal and cyclic behaviors of fire-damaged walls designed with different failure modes, aspect ratios and heated areas. These cyclic behaviors include temperature distribution, maximum lateral load, stiffness, ductility, and energy dissipations, etc. Toward this goal, the concrete wall specimens were exposed to heat following an ISO 834 standard time–temperature curve and the cyclic loading was applied to the fire-damaged walls. The test results showed that exposure to fire significantly reduced the cyclic performance of the RC walls. Especially, it was observed that heated area, designed failure mode, and aspect ratio have influences on maximum lateral loads, stiffness, and ductility of the fire-damaged walls, while almost no effects of the heated area, designed failure mode, and aspect ratio on temperature distribution and energy dissipation were found.


2021 ◽  
Vol 933 (1) ◽  
pp. 012008
Author(s):  
A H Prathama ◽  
M Teguh ◽  
F Saleh

Abstract The growing growth of human activities has led to changes in housing patterns in urban areas. The land crisis in urban areas has made land prices uneconomical, so buildings are designed vertically. One solution to resist earthquakes in multi-story buildings is to add a shear wall structure with the proper profile and layout. Shear wall designs with variations influence the base shear, drift ratio, lateral deflection, and story drift patterns. This study presents the structural response comparison of buildings against variations in the profile and layout of shear walls subjected to earthquake loads. Force Based Design method utilizing the response spectrum approach was adopted in the analysis and carried out using SAP200. Six structural models comprise a frame without shear walls, three L-profile shear walls, two I-profile (straight) shear walls. The simulation results of the overall structural models show that the profile and layout configuration of shear walls in the frame structure of a multi-story building correlates directly to the performance of base shear, drift ratio, and story drift with relatively comparative conditions.


Author(s):  
Hridya. K

Torsion force is a load that is a applied to a building through torque. The torque applied creates a shear stress. If a torsion force is large enough, it can cause a building to undergo a twisting action. The main aim of the project is to study the effect of location of shear wall on torsional performance of symmetric and asymmetric high-rise building ,post tensioned slabs are being used in the construction of building hence the thesis also analyze these post tensioned slab structures by changing shear wall configuration. Post tensioned slab structures have weak resistance to lateral loads. so to provide stiffness to structures against lateral forces shear walls are used. A study of 30 storey building in zone III, is considered and determine various parameters like base shear, storey drift, and storey displacement.post-tensioning is a mature technology as it provide efficient, economic and elegant structural solutions for a wide range of applications. Post-tensioned flat slab could be a better option compared to RCC flat slab, in respect of the cost of project and time of construction. ETABS 2017 software is used for the analysis.


Author(s):  
Varun Mahajan

Abstract: Architects nowadays develop attractive edifices, and floating columns are widely employed in this process. Floating columns are used not only to provide a magnificent perspective but also when a vast open area is necessary. Edifices with irregular configurations are more vulnerable to earthquakes and hence, suitable shear wall placement is required to ensure the edifice's stability. Many multi-storey edifices collapsed in seconds after the Bhuj Earthquake (Jan 26, 2001), due to the presence of soft stories, floating columns, and mass anomalies. As a result, knowing the seismic reactions of these buildings are vital for constructing earthquake-resistant assemblies. The relevance of a Floating Column and the existence of a shear wall in an irregular multistorey building is highlighted in this study. Dynamic seismic behaviour of a G+18 irregular edifice with different locations of the floating column and different positions of the shear wall is explored in this research. The edifice is analysed and compared with the model without shear walls and floating columns to examine the alterations. The dynamic analysis is carried out using Response Spectrum Analysis and storey drift, storey displacement and base shear are calculated and finally, software compression is computed for different zones. The analysis is carried out by Indian standardized codes IS 1893:2016 and IS 456:2000 which are the codes specified by the Bureau of Indian Standards for earthquake resistance edifice design and plain and reinforcement concrete design respectively. Keywords: Floating Column, Shear Wall, Irregular Edifice, Seismic behaviour, Response Spectrum Analysis, storey drift, storey displacement, base shear.


2021 ◽  
Vol 6 (2) ◽  
Author(s):  
Mahammad Fayeemuddin ◽  
A. Vimala

The performance of any structure under lateral loads depends on its structural configuration. Most of the codes worldwide mentioned the provisions for the lateral load analysis for regular structures. Structures may be irregular in practice due to uneven distributions in mass, stiffness and strength. In India, most common type of multi-storied apartments constructed varies from 5 to 15 storeys and many apartments are constructed with penthouse which creates mass irregularity in the structures. The present study investigates the performance of mass irregular structures which are created by providing penthouse and also modeled as a stepped setback structure. Total four structures, 5, 7, 11 and 16 storied with an aspect ratio (height to width of the structure) of 0.64, 0.88, 1.36 and 1.96 are considered. For each structure response spectrum analysis is carried and the response parameters like storey displacements, storey drift and base shear variation in 4 seismic zones of India is studied. The main focus of the investigation is to understand the acceptance of mass irregularity with respect to the aspect ratio of the structure. The acceptance limit of the mass irregularity is also investigated as per 4 seismic zones of India. The results are compared with Indian standard code limits and concluded the acceptance limit as per seismic zones of India.


Author(s):  
Mr. Prashant Sharma

Abstract: To decrease the overall cost of the project, it is highly recommended dropping the cost in different manners. To make economic structure, structure without losing the stiffness standards and the cost cutting should be done at every construction stages. The dual systems in building structure consist of structural walls and moment resisting frames. The walls are made up of RCC, which is expensive material. The purpose of current study is to discover the effect of reducing shear wall area in multistorey building to decrease cost. The buildings are provided with shear walls to improve the lateral load resistance. Post parametric analysis results shows that, the reduction in shear wall area should be modified to a certain limit up to 20 % for cost cutting. But in this study, the opening areas of shear wall are increased above 20% to 36.75% and verify the results of post analysis. In this study 8 cases are analysed with 0%, 11%, 14.20%, 20%, 33.20%, 29.05%, 35%, & 36.75% opening in shear wall and analysis is perform by Response Analysis Method of dynamic analysis using Staad.pro V8i software in Zone III of multistorey building (G+18). The effects of opening in the wall are studied by considering the moments, shear, and torsion, and axial forces in the beams and columns. It is observed that after a certain percentage of shear opening in walls the building fails in the drift at a certain height. To resolve this problem the flared area of height 0.5 m at the height of failure is provided to counteract the effect of drift. It was observed that by the introduction of shear belt the drift reduces which made the structure stable. Finally in this study, the opening of shear wall area is increased up to 35% and concrete area is reduced 1170.20 m2 , which is 534.2m2 more than the previous studies. Keywords: Shear Wall, Opening Area, Multi-storeyed Building, Seismic effects, Response Spectrum Method


CONSTRUCTION ◽  
2021 ◽  
Vol 1 (2) ◽  
pp. 93-101
Author(s):  
Saffuan Wan Ahmad ◽  
Muhammad Aimran Amzar Kamarudin ◽  
Wan Aniq Ridhwan Wan Ariffin

On the 5th June 2015, an earthquake hit Ranau, Sabah with a magnitude of 6.0 that caused 18 casualties and several injuries are one of the examples that show Malaysia is not safe from any seismic event. Most of the structure in Malaysia was designed not to include seismic action.  Furthermore, an area that has a high density of population such as in the central region (Klang valley) and several main cities in Malaysia has less available land to build landed housing and uses high-rise apartments as an alternative. High-rise buildings that are normally having problems with soft story mechanisms and plan irregularity which could lead to severe damage when earthquakes happen. This study aims to observe the response of high-rise buildings when under different earthquakes in the presence of shear walls. To achieve this objective two models were modelled and analyzed by using ETABS software, the one with a shear wall and the one with no shear wall. The methods used in this study were the response spectrum method and time-history analysis. In the end, the parameters observed were base shear, story stiffness, story drift, and story displacement. The observations highlighted that the effect of earthquake intensities shows a significant effect. The acquired results indicated that the building with the shear wall is more resistant and strong structures as compared to buildings without shear wall when undergoing seismic analysis.


Flat slab is a reinforced concrete slab supported directly by concrete columns without the use of beams .However; in multi-storey buildings it has weak resistance to the lateral loads. Hence this work is concerned to decrease the damage under lateral loading and to minimize the displacement. Shear wall are used to provide stability to structures from lateral loads. The aim of the present study is to analyze effect of shear wall and perimeter beam for flat slab building, and also effectiveness of core shear wall. For present work five models are studied 1) conventional slab building 2) simple flat slab building considered without any drop and column head 3) flat slab with drop building is considered without column head 4) flat slab with drop with perimeter beam building 5) flat slab with perimeter beam and shear wall buildings, each of plan size 25mX25m are selected. For stabilization of structural parameters, shear wall are provided. The seismic parametric studies comprise of roof displacement, base shear, and sequence of hinge formation .from study it concluded that the shear walls significantly increases the base shear capacity and reduces roof displacement and also getting good Performance


2012 ◽  
Vol 39 (8) ◽  
pp. 867-877 ◽  
Author(s):  
Damien Gilles ◽  
Ghyslaine McClure

Structural engineers routinely use rational dynamic analysis methods for the seismic analysis of buildings. In linear analysis based on modal superposition or response spectrum approaches, the overall response of a structure (for instance, base shear or inter-storey drift) is obtained by combining the responses in several vibration modes. These modal responses depend on the input load, but also on the dynamic characteristics of the building, such as its natural periods, mode shapes, and damping. At the design stage, engineers can only predict the natural periods using eigenvalue analysis of structural models or empirical equations provided in building codes. However, once a building is constructed, it is possible to measure more precisely its dynamic properties using a variety of in situ dynamic tests. In this paper, we use ambient motions recorded in 27 reinforced concrete shear wall (RCSW) buildings in Montréal to examine how various empirical models to predict the natural periods of RCSW buildings compare to the periods measured in actual buildings under ambient loading conditions. We show that a model in which the fundamental period of RCSW buildings varies linearly with building height would be a significant improvement over the period equation proposed in the 2010 National Building Code of Canada. Models to predict the natural periods of the first two torsion modes and second sway modes are also presented, along with their uncertainty.


2021 ◽  
Vol 11 (1) ◽  
pp. 6043-6063
Author(s):  
Ali Jafarian ◽  
Seyed Babak Jafarian

Considering the increase in the current construction process and the future needs of Iran, the necessity to use high-rise buildings for reduction in urbanization costs and optimal use of land will be inevitable in the future. The performance of steel plate shear wall system as a modern global system, which has an effective application in high-rise buildings and also brings economic benefits compared to previous systems, is evaluated in this study. Steel Plate Shear Walls (SPSW) are a new type of system resistant to wind and earthquake lateral loads, which dates back to the 1970s. In this research, eight samples of shear wall with various stiffening arrangements and sections with ST37 and ST52 alloys are modeled. To evaluate the nonlinear dynamic analysis, the samples are subjected to the San Fernando earthquake force and are modeled and analyzed by ABAQUS software based on the finite element theory. The results of analyzing the samples indicate better performance of the system with stiffener in both vertical and horizontal directions. Also, the use of sections with ST52 alloy has improved the performance of the shear wall by approximately 40%.


Sign in / Sign up

Export Citation Format

Share Document