Alternative Improvement Plans for Removal Efficiency of Plating Wastewater Treatment Processes

2016 ◽  
Vol 20 ◽  
pp. 31-37
Author(s):  
Xin-Chao Ma ◽  
◽  
Bong-Su Lim ◽  
Chan-Soo Choi
Processes ◽  
2020 ◽  
Vol 8 (6) ◽  
pp. 720 ◽  
Author(s):  
Jin-Pil Kim ◽  
Dal Rae Jin ◽  
Wonseok Lee ◽  
Minhee Chae ◽  
Junwon Park

In this study, livestock wastewater treatment plants in South Korea were monitored to determine the characteristics of influent and effluent wastewater, containing four types of veterinary antibiotics (sulfamethazine, sulfathiazole, chlortetracycline, oxytetracycline), and the removal efficiencies of different treatment processes. Chlortetracycline had the highest average influent concentration (483.7 μg/L), followed by sulfamethazine (251.2 μg/L), sulfathiazole (230.8 μg/L) and oxytetracycline (25.7 μg/L), at five livestock wastewater treatment plants. Sulfathiazole had the highest average effluent concentration (28.2 μg/L), followed by sulfamethazine (20.8 μg/L) and chlortetracycline (11.5 μg/L), while no oxytetracycline was detected. For veterinary antibiotics in the wastewater, a removal efficiency of at least 90% was observed with five types of treatment processes, including a bio-ceramic sequencing batch reactor, liquid-phase flotation, membrane bioreactor, bioreactor plus ultrafiltration (BIOSUF) and bio best bacillus systems. Moreover, this study evaluated the removal efficiency via laboratory-scale experiments on the conventional contaminants, such as organic matter, nitrogen, phosphorus and veterinary antibiotics. This was done using the hydraulic retention time (HRT), under three temporal conditions (14 h, 18 h, 27 h), using the anaerobic–anoxic–oxic (A2O) process, in an attempt to assess the combined livestock wastewater treatment process where the livestock wastewater is treated until certain levels of water quality are achieved, and then the effluent is discharged to nearby sewage treatment plants for further treatment. The removal efficiencies of veterinary antibiotics, especially oxytetracycline and chlortetracycline, were 86.5–88.8% and 87.9–90.8%, respectively, exhibiting no significant differences under various HRT conditions. The removal efficiency of sulfamethazine was at least 20% higher at HRT = 27 h than at HRT = 14 h, indicating that sulfamethazine was efficiently removed in the A2O process with increased HRT. This study is expected to promote a comprehensive understanding of the behavior and removal of veterinary antibiotics in the livestock wastewater treatment plants of South Korea.


2015 ◽  
Vol 72 (10) ◽  
pp. 1789-1795 ◽  
Author(s):  
T. Ito ◽  
T. Kato ◽  
K. Takagishi ◽  
S. Okabe ◽  
D. Sano

Left-censored datasets of virus density in wastewater samples make it difficult to evaluate the virus removal efficiency in wastewater treatment processes. In the present study, we modeled the probabilistic distribution of virus removal efficiency in a wastewater treatment process with a Bayesian approach, and investigated how many detect samples in influent and effluent are necessary for accurate estimation. One hundred left-censored data of virus density in wastewater (influent and effluent) were artificially generated based on assumed log-normal distributions and the posterior predictive distribution of virus density, and the log-ratio distribution were estimated. The estimation accuracy of distributions was quantified by Bhattacharyya coefficient. When it is assumed that the accurate estimation of posterior predictive distributions is possible when a 100% positive rate is obtained for 12 pairs of influent and effluent, 11 out of 144, 60 out of 324, and 201 out of 576 combinations of detect samples gave an accurate estimation at the significant level of 0.01 in a Kruskal-Wallis test when the total sample number was 12, 18, and 24, respectively. The combinations with the minimum number of detect samples were (12, 9), (16, 10), and (21, 8) when the total sample number was 12, 18, and 24, respectively.


2008 ◽  
Vol 57 (1) ◽  
pp. 49-56 ◽  
Author(s):  
C. Miège ◽  
J.M. Choubert ◽  
L. Ribeiro ◽  
M. Eusèbe ◽  
M. Coquery

We created a database in order to quantitatively assess the occurrence and removal efficiency of PPCPs in WWTPs. From 113 scientific publications, we compiled 5887 data on the concentrations and loads of PPCPs in WWTP influents and effluents, and on their removal efficiency. The first outputs of our database include: (1) a list of the most frequently studied molecules, their frequency of detection, their mean concentration and removal in liquid influent and effluent; (2) a comparison of the removal efficiency for different WWTP processes; (3) a study of the influence of the operating conditions (sludge and hydraulic retention times).


2015 ◽  
Vol 72 (3) ◽  
pp. 463-471 ◽  
Author(s):  
Intira Pookpoosa ◽  
Ranjna Jindal ◽  
Daisy Morknoy ◽  
Kraichat Tantrakarnapa

Investigations were carried out on the occurrence and fate of bisphenol A (BPA) in five wastewater treatment plants (WWTPs) in Bangkok, namely, Rattanakosin, Chong Non Si, Din Daeng (DD), Nong Khaem and Thungkru (TK) during three sampling events between October 2013 and February 2014. Based on the results, the influent and effluent BPA concentrations ranged between 128.5 ng/L and 606.0 ng/L; and 38.7 ng/L and 270.5 ng/L, respectively. The effluent BPA concentrations of most of the five WWTPs were lower than the influent levels. TK had the highest removal efficiency in October 2013 (80.4%) and December 2013 (90.7%) and the second highest in February 2014 (69.2%). DD had the highest removal efficiency in February 2014 (91.8%). The treatment processes employed at TK and DD were vertical loop reactor activated sludge process and activated sludge with nutrients removal, respectively. Thus, these processes seem to be good for BPA degradation.


2006 ◽  
Vol 5 (4) ◽  
pp. 685-692
Author(s):  
Elisabeta Chirila ◽  
Ionela Carazeanu Popovici ◽  
Techin Ibadula ◽  
Alice Iordache

Author(s):  
N. Zaletova ◽  
S. Zaletov

Биологический метод очистки сточных вод представляет собой сложный многокомпонентный процесс, ключевой составляющей которого является работа ферментной системы. Известно, что одним из важнейших ферментов, обеспечивающих биологический процесс, являются дегидрогеназы. Полностью сложнейший механизм действия ферментов до конца пока не раскрыт, однако в практике контроля процессов биологической очистки используется показатель дегидрогеназной активности ила. Результаты исследований позволили дополнить имеющуюся информацию фактическими данными о взаимообусловленности уровня дегидрогеназной активности ила и показателей отдельных технологических параметров биологической очистки. Показано, что режим работы аэротенков (нагрузка на ил, доза активного ила и др.) и величина показателей исходной дегидрогеназной активности и дегидрогеназной активности этого же образца ила со слабо концентрированным раствором (ДАИН2О) связаны между собой и зависят от нагрузки на ил по органическим веществам. Полученные результаты исследования могут быть использованы для контроля биологического процесса очистки сточных вод.The biological method of wastewater treatment is a comprehensive multicomponent process the activities of the enzyme system being the key component of it. It is known that dehydrogenases have been one of the most important enzymes the ensure the biological process. The complicated mechanism of the action of enzymes has not been fully described so far however, in the practice of monitoring biological treatment processes, an indicator of the dehydrogenase activity of sludge is used. The research results provided for supplementing the available information with actual data on the interdependence of the level of dehydrogenase activity of sludge and indicators of individual process parameters of biological treatment. It was shown that the mode of operation of aeration tanks (organic matter load on sludge, dose of activated sludge, etc.) and the values of the initial dehydrogenase activity and dehydrogenase activity of the same sludge sample with weakly concentrated solution (DASН2О) are interconnected and depend on the organic load on sludge. The results of the study can be used to control the biological process of wastewater treatment.The biological method of wastewater treatment is a comprehensive multicomponent process the activities of the enzyme system being the key component of it. It is known that dehydrogenases have been one of the most important enzymes the ensure the biological process. The complicated mechanism of the action of enzymes has not been fully described so far however, in the practice of monitoring biological treatment processes, an indicator of the dehydrogenase activity of sludge is used. The research results provided for supplementing the available information with actual data on the interdependence of the level of dehydrogenase activity of sludge and indicators of individual process parameters of biological treatment. It was shown that the mode of operation of aeration tanks (organic matter load on sludge, dose of activated sludge, etc.) and the values of the initial dehydrogenase activity and dehydrogenase activity of the same sludge sample with weakly concentrated solution (DASН2О) are interconnected and depend on the organic load on sludge. The results of the study can be used to control the biological process of wastewater treatment.


Sign in / Sign up

Export Citation Format

Share Document