Back-to-back Layered Co-culture on a SiN Porous Membrane for Stable Measurement of Neuronal Extracellular Potentials

2021 ◽  
Vol 141 (7) ◽  
pp. 215-221
Author(s):  
Satoshi Yoshida ◽  
Takashi Yasuda
1997 ◽  
Vol 35 (8) ◽  
pp. 137-144 ◽  
Author(s):  
Tsuyoshi Nomura ◽  
Takao Fujii ◽  
Motoyuki Suzuki

Porous membrane of poly(tetrafluoroethylene) (PTFE) was formed on the surface of porous ceramic tubes by means of heat treatment of the PTFE particles deposit layer prepared by filtering PTFE microparticles emulsified in aqueous phase. By means of inert gas permeation, pore size was determined and compared with scanning electron micrograph observation. Also rejection measurement of aqueous dextran solutions of wide range of molecular weights showed consistent results regarding the pore size. Since the membrane prepared by this method is stable and has unique features derived from PTFE, it is expected that the membrane has interesting applications in the field of water treatment. Membrane separation of activated sludge by this composite membrane and original ceramics membrane showed that the PTFE membrane gives better detachability of the cake layer formed on the membrane. This might be due to the hydrophobic nature of the PTFE skin layer.


1986 ◽  
Vol 51 (10) ◽  
pp. 2077-2082 ◽  
Author(s):  
Jan Langmaier ◽  
František Opekar

Gold porous membrane electrode has been used for the potentiometric determination of small amounts of sulfur dioxide absorbed in the solutions of sodium tetrachloromercurate or sodium hydroxide. Sulfur dioxide is released by the reaction with an acid into a stream of nitrogen and led to the electrode immersed into the solution of iodine monochloride. Part of SO2 penetrates through the membrane pores into the solution where it is oxidized. The electrode redox potential change is a measure of the SO2 concentration in the absorption solution. In the solution of 1 . 10-5 M[ICl2]- in 0.02 M-HClO4 the limit of quantitation was found to be 0.07 ng SO2 . ml-1. The relative standard deviations of 1.4% and 2.5% were found for the determinations of 10 ng and 0.5 ng of SO2, respectively. Higher concentrations of H2S interfere only in the hydroxide solution. About 10 samples can be analyzed per one hour.


2021 ◽  
pp. 152808372110142
Author(s):  
Ariana Khakpour ◽  
Michael Gibbons ◽  
Sanjeev Chandra

Porous membranes find natural application in various fields and industries. Water condensation on membranes can block pores, reduce vapour transmissibility, and diminish the porous membranes' performance. This research investigates the rate of water vapour transmission through microporous nylon and nanofibrous Gore-Tex membranes. Testing consisted of placing the membrane at the intersection of two chambers with varied initial humidity conditions. One compartment is initially set to a high ([Formula: see text]water vapour concentration and the other low ([Formula: see text], with changes in humidity recorded as a function of time. The impact of pore blockage was explored by pre-wetting the membranes with water or interposing glycerine onto the membrane pores before testing. Pore blockage was measured using image analysis for the nylon membrane. The mass flow rate of water vapour ( ṁv) diffusing through a porous membrane is proportional to both its area (A) and the difference in vapour concentration across its two faces ([Formula: see text], such that [Formula: see text] where K is defined as the moisture diffusion coefficient. Correlations are presented for the variation of K as a function of [Formula: see text]. Liquid contamination on the porous membrane has been shown to reduce the moisture diffusion rate through the membrane due to pore blockage and the subsequent reduced open area available for vapour diffusion. Water evaporation from the membrane's surface was observed to add to the mass of vapour diffusing through the membrane. A model was developed to predict the effect of membrane wetting on vapour diffusion and showed good agreement with experimental data.


Sensors ◽  
2021 ◽  
Vol 21 (10) ◽  
pp. 3328
Author(s):  
Pouya Mehrdel ◽  
Hamid Khosravi ◽  
Shadi Karimi ◽  
Joan Antoni López Martínez ◽  
Jasmina Casals-Terré

Microfluidic paper-based analytical devices (µPADs) are a promising technology to enable accurate and quantitative in situ assays. Paper’s inherent hydrophilicity drives the fluids without the need for external pressure sources. However, controlling the flow in the porous medium has remained a challenge. This study addresses this problem from the nature of the paper substrate and its design. A computational fluid dynamic model has been developed, which couples the characteristics of the porous media (fiber length, fiber diameter and porosity) to the fluidic performance of the diffusion-based µPAD sensor. The numerical results showed that for a given porous membrane, the diffusion, and therefore the sensor performance is affected not only by the substrate nature but also by the inlets’ orientation. Given a porous substrate, the optimum performance is achieved by the lowest inlets’ angle. A diffusion-based self-referencing colorimetric sensor was built and validated according to the design. The device is able to quantify the hydronium concentration in wines by comparison to 0.1–1.0 M tartaric acid solutions with a 41.3 mM limit of detection. This research showed that by proper adjustments even the simplest µPADs can be used in quantitative assays for agri-food applications.