scholarly journals Determination of Mefenamic Acid in Pharmaceutical Drugs and Wastewater by RP-HPLC

Author(s):  
Mohammad Anas Alfeen

This study presents a chromatographic analysis method for the determination of mefenamic acid in pharmaceutical preparations and treated wastewater from the pharmaceutical industry in East Asia and specifically (Syria). An isocratic RP-HPLC method has been developed for determination of Mefenamic acid on a Grace, alltima C18 column (250 x 4.6 mm, 5.0 μm) using a mobile phase consisting of (1%) Triethylamine aqueous buffer adjust pH = 2 by H3PO4 (85%): Methanol: Acetonitrile); (35: 20: 45 v\v\v %) at a flow rate of 2 mL/min. Detection was carried out at 220 nm. Retention time of Mefenamic acid was 7.85 ( ± 0.36) mins. The method was validated with respect to specificity, linearity, accuracy, precision, ruggedness, and robustness.  The proposed method is simple, precise, sensitive, and reproducible and is applicable for quantification of Mefenamic acid in Tablets formulations and Wastewater developed and formulated in our laboratory.

2021 ◽  
Vol 9 (1) ◽  
pp. 141-149
Author(s):  
Romana Mahivish ◽  
Manjunath SY ◽  
Hemant Kumar

A simple, rapid, accurate and precise RP-HPLC method was developed and validated for the determination of zileuton in table dosage form. Chromatographic analysis of the drug was achieved on Cyberlab HPLC comprising of LC- 100P pump, a variable wavelength programmable LC-UV100 UV detector and SCL system controller.  Flowrosil C18 column (250 mm x 4.6 mm, 5 μ) as stationary phase with mobile phase consisting of Methanol: Acetonitrile: 1% GAA in the ratio of 70:10:20 v/v. The method showed a good linear response in the concentration range of 5-30 μg/ml with correlation coefficient of 0.9993. The flow rate was maintained at 1.0 ml/min and detection was carried out at 230 nm. The retention time was 3.12 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, solution stability, selectivity and sensitivity. The results obtained in the study were within the limits of ICH guidelines and hence this method can be used for the determination of zileuton in tablet formulation.


Author(s):  
M. Maithani ◽  
D. Dwivedi ◽  
D. Hatwal ◽  
P. Bansal

A simple and precise RP-HPLC method for the estimation of Erdafitinib in tablet dosage form was developed and validated. The chromatographic separation of the drug was done with a Hypersil™ ODS C18 Column (150 mm × 4.6 mm i.d., particle size 5 μ) using 20mM sodium acetate buffer (pH 4. ±0.02), methanol and acetonitrile (60:10:30 v/v/v) as a mobile phase. The instrument was set at flow rate of 1.0 mLmin-1 at ambient temperature and the wavelength of UV-visible detector at 310nm. The method showed excellent linearity over a range of 5-35 μgmL-1 for the drug. The correlation coefficient for Erdafitinib was noted to be 0.9999. The mean recovery values were found to be 99.77% and 100.88%. The results suggest that the proposed method could be suitable for quantitative determination of Erdafitinib in pharmaceutical preparations and also for quality control in bulk manufacturing. The F-test and t-test at 95% confidence level were applied on data for statistical analysis.


2019 ◽  
Vol 9 (o3) ◽  
Author(s):  
Imad Tarek Hanoon ◽  
Abed Mohammed Daheir AL-Joubory 2 ◽  
Marwa Mohamed Saied 3

A simple , specific, accurate and precise RP-HPLC method was developed for determination of Irbesartan (IRB) in pharmaceutical dosage forms in tablets products and sachet using symmetry (L 1 ) column at 30°C . The signal was detected at 225 nm. A mobile phase dissolve 0.5 g of buffer potassium phosphate in 100 ml distilled water and adjust pH 2.7 , methanol and acetonitrile at ratio (40 :30 :30 ) . and flow rate 1.2ml/min -1 at pH=7.2 a mobile phase The percent recovery was detected 101 % and the linearity of concentration was 10-50 µg.ml -1 and supported this method by using (FT.I.R.) spectrum method for organic spectrophotometer to prove the chemical structure of this drug and some physical properties . we are obtained the result is identical of other literature . The proposed method was applied successfully for determination of the IRB in tablets products.


Separations ◽  
2021 ◽  
Vol 8 (1) ◽  
pp. 5
Author(s):  
Mohd Afzal ◽  
Mohd. Muddassir ◽  
Abdullah Alarifi ◽  
Mohammed Tahir Ansari

A highly specific, accurate, and simple RP-HPLC technique was developed for the real-time quantification of domperidone (DOMP) and lansoprazole (LANS) in commercial formulations. Chromatographic studies were performed using a Luna C8(2), 5 μm, 100Å, column (250 × 4.6 mm, Phenomenex) with a mobile phase composed of acetonitrile/2 mM ammonium acetate (51:49 v/v), pH 6.7. The flow rate was 1 mL·min−1 with UV detection at 289 nm. Linearity was observed within the range of 4–36 µg·mL−1 for domperidone and 2–18 µg·mL−1 for lansoprazole. Method optimization was achieved using Box-Behnken design software, in which three key variables were examined, namely, the flow rate (A), the composition of the mobile phase (B), and the pH (C). The retention time (Y1 and Y3) and the peak area (Y2 and Y4) were taken as the response parameters. We observed that slight alterations in the mobile phase and the flow rate influenced the outcome, whereas the pH exerted no effect. Method validation featured various ICH parameters including linearity, limit of detection (LOD), accuracy, precision, ruggedness, robustness, stability, and system suitability. This method is potentially useful for the analysis of commercial formulations and laboratory preparations.


2006 ◽  
Vol 3 (1) ◽  
pp. 60-64 ◽  
Author(s):  
P. Venkata Reddy ◽  
B. Sudha Rani ◽  
G. Srinu Babu ◽  
J. V. L. N. Seshagiri Rao

A reverse phase HPLC method is developed for the determination of Raloxifene in pharmaceutical dosage forms. Chromatography was carried out on an inertsil C18 column using a mixture of acetonitrile and phosphate buffer (30:70 v/v) as the mobile phase at a flow rate of 1 mL/min. Detection was carried out at 290 nm .The retention time of the drug was 10.609 min. The method produced linear responses in the concentration range of 0.5-200 µg/mL of Raloxifene. The method was found to be applicable for determination of the drug in tablets.


INDIAN DRUGS ◽  
2014 ◽  
Vol 51 (12) ◽  
pp. 32-36
Author(s):  
T. Vishalakhi ◽  
◽  
S. K Kumar ◽  
K Sujana ◽  
P Rani

A simple validated RP HPLC method for the estimation of rizatriptan benzoate in pharmaceutical dosage form and bulk was developed for routine analysis. This method was developed by selecting Agilent TC C18 (250 x 4.6 mm, 5 μ) column as stationary phase and acrylonibrile:water (45:55), pH adjusted to 3, as mobile phase. Flow rate of mobile phase was maintained at 4: 1 mL/min at ambient temperature throughout the experiment. Quantification was achieved with ultraviolet (DAD) detection at 220 nm. The retention time obtained for rizatriptan was 2.8 min. The detector response was linear in the concentration range of 2-25μg/mL. This method was validated and shown to be specific, sensitive, precise, linear, accurate, rugged and robust. Hence, this method can be applied for routine quality control of rizatriptan benzoate in dosage forms as well as in bulk drug.


2010 ◽  
Vol 7 (1) ◽  
pp. 246-252 ◽  
Author(s):  
S. K. Patro ◽  
S. K. Kanungo ◽  
V. J. Patro ◽  
N. S. K. Choudhury

A simple, rapid and accurate and stability indicating RP-HPLC method was developed for the determination of valsartan in pure and tablet forms. The method showed a linear response for concentrations in the range of 50-175 µg/mL using 0.01 M NH4H2PO4(pH 3.5) buffer: methanol [50:50] as the mobile phase with detection at 210 nm and a flow rate of 1 mL/min and retention time 11.041 min. The method was statistically validated for accuracy, precision, linearity, ruggedness, robustness, forced degradation, solution stability and selectivity. Quantitative and recovery studies of the dosage form were also carried out and analyzed; the % RSD from recovery studies was found to be less than 1. Due to simplicity, rapidity and accuracy of the method, we believe that the method will be useful for routine quality control analysis.


INDIAN DRUGS ◽  
2018 ◽  
Vol 55 (03) ◽  
pp. 32-42
Author(s):  
G. P Wani ◽  
◽  
S. B Jadhav

Simple, rapid, precise, accurate RP-HPLC and HPTLC methods have been developed and validated for ivermectin in bulk and its marketed formulation. RP-HPLC method for drug was achieved on Grace C18 (250 mm X 4.6 ID, Particle size; 5 μ) column using mobile phase acetonitrile: 10 mM phosphate buffer (95:05 v/v) pH adjusted to 3 with o-phosphoric acid. Detection of drug was done at 245 nm. The retention time was found to be 5.83 min. HPTLC method for ivermectin was accomplished on a precoated silica gel aluminium plate 60F-254 (CAMAG Linomat 5), using toluene: methanol: glacial acetic acid (8:2:0.1 v/v/v) as a mobile phase. The densitometric scanning was performed at 245 nm which showed Rf 0.46 for ivermectin. The stress testing of the drug individually was carried out under acidic, alkaline, oxidation, photo-stability and thermal degradation conditions. The proposed methods were successfully applied for the determination of drug in bulk and its marketed formulation.


INDIAN DRUGS ◽  
2016 ◽  
Vol 53 (08) ◽  
pp. 48-52
Author(s):  
K. P Parekh ◽  
◽  
A. P. Jadhav

A simple, accurate, precise, robust stability indicating RP-HPLC method was developed and validated for simultaneous estimation of berberine and curcumin in an ayurvedic formulation. The two markers were resolved using a C-18 column using as the mobile phase methanol: water (pH 3 adjusted using acetic acid) in the ratio 75:25 V/V at a flow rate of 1mL/min. Retention times of berberine and curcumin were 2.58 ± 0.2 min and 8.5 ± 0.2 min, respectively at 358 nm. Linear response was observed in the concentration range of 2 – 8 ppm for berberine and 5 – 40 ppm for curcumin, with correlation coefficient (r2) of 0.994 and 0.998 for berberine and curcumin, respectively. The developed method was applied for quantitation of markers in marketed and in-house formulations of Gruhadhoomadi Churna. This method can also be used to evaluate formulations containing berberine and curcumin as markers, thus conforming to the need of ensuring quality and safety of herbal medicines.


2012 ◽  
Vol 2012 ◽  
pp. 1-4 ◽  
Author(s):  
Shravan Bankey ◽  
Ganesh Tapadiya ◽  
Jasvant Lamale ◽  
Deepti Jain ◽  
Shweta Saboo ◽  
...  

A simple, accurate, and precise HPLC method was developed and validated for determination of rimonabant in human plasma. Following liquid-liquid extraction, chromatographic separation was accomplished using C18 column with mobile phase consisting of acetonitrile : water (90 : 10, v/v), drug was detected at 260 nm using UVdetector. The LOD and LOQ were 3.0 and 10.0 μg/L, respectively. The method is linear in the interval 50.0–1000.0 μg/L. The average extraction recovery of drug from plasma was found to be 92.2%. The percent CV of the method was found to be less than 10.8%, and accuracy was found between 94.5 and 106.7%. The assay may be applied to a pharmacokinetic and bioequivalence study of rimonabant.


Sign in / Sign up

Export Citation Format

Share Document