scholarly journals EFEK SAMPING RADIASI SINAR X DAN SINAR GAMMA PADA DAYA TAHAN RONGGA MULUT

2016 ◽  
Vol 1 (1) ◽  
pp. 31
Author(s):  
Hj. Barunawaty
Keyword(s):  
X Ray ◽  

The Radiation which usually use in the Medical World is theX-ray radiation and Gamma ray radiation. Both uses forradiodiagnostic and radiotheraphy, have same characteristicbut from difffent well. X-ray source from X-rayequipmentwhichwork of art Human, whereas Gamma raysource from radioac-tive materialswhich to spout accordingspontaneous andnatu-ralcharacteristic. The use of ionizingradiation high dose which to use in radiotherapy possible togive sideeffect at defence oral component and others bodyeels which still healthy.

Nukleonika ◽  
2016 ◽  
Vol 61 (1) ◽  
pp. 49-52 ◽  
Author(s):  
Monika Paluch-Ferszt ◽  
Beata Kozłowska ◽  
Susana Oliveira de Souza ◽  
Luiza Freire de Souza ◽  
Divanizia Nascimento Souza

AbstractMagnesium tetraborate doped with dysprosium (MgB4O7:Dy) is known as a good thermoluminophor for personal dosimetry of gamma ray and X-ray radiation because of its high sensitivity and close tissue equivalence. This material can be produced by different routes. The sintered pastilles of magnesium tetraborate mixed with Teflon (40%) used in this work were manufactured at the Federal University of Sergipe, Department of Physics by the solid-state synthesis. Magnesium tetraborate was already used for high-dose dosimetry, exhibiting linearity for a wide range of doses. In this work, the authors examined its main characteristics prior to potential use of detectors in everyday dosimetry, comparing this material to a widely used LiF:Mg,Ti phosphor. The following tests influencing dosimetric peaks of MgB4O7:Dy were presented: (1) the shape of the glow curves, (2) annealing conditions and post-irradiation annealing and its influence for background of the detectors, (3) the choice of the heating rates at the read-out and (4) the threshold dose, that is, the lowest possible dose to be measured. Similar tests were performed with LiF:Mg,Ti detectors, produced and widely used in Poland. The results were compared and discussed.


Author(s):  
L. T. Germinario ◽  
J. Blackwell ◽  
J. Frank

This report describes the use of digital correlation and averaging methods 1,2 for the reconstruction of high dose electron micrographs of the chitin-protein complex from Megarhyssa ovipositor. Electron microscopy of uranyl acetate stained insect cuticle has demonstrated a hexagonal array of unstained chitin monofibrils, 2.4−3.0 nm in diameter, in a stained protein matrix3,4. Optical diffraction Indicated a hexagonal lattice with a = 5.1-8.3 nm3 A particularly well ordered complex is found in the ovipositor of the ichneumon fly Megarhyssa: the small angle x-ray data gives a = 7.25 nm, and the wide angle pattern shows that the protein consists of subunits arranged in a 61 helix, with an axial repeat of 3.06 nm5.


1987 ◽  
Vol 48 (C9) ◽  
pp. C9-367-C9-370
Author(s):  
C. B. COLLINS ◽  
F. DAVANLOO ◽  
T. S. BOWEN ◽  
J. J. COOGAN
Keyword(s):  

2003 ◽  
Vol 8 (5-6) ◽  
pp. 60-64
Author(s):  
A.I. Arkhangelsky ◽  
◽  
Yu.D. Kotov ◽  
P.Yu. Chistiakov ◽  
◽  
...  

2019 ◽  
Vol 9 (02) ◽  
Author(s):  
Amal Kamil Abdul Sada ◽  
Amany Mohamed Al-Kaysi

This is an experimental trial to prepare a vaccine from gamma-irradiated Giardia lamblia which is evaluated in experimental animals. The study was conducted from December 2015 to April 2016. The field survey of the parasite was conducted from those patients attending the laboratories of the Alawi Children's Hospital in Rusafa and the Al-Yarmouk Teaching Hospital in Karkh, through which 1250 stool samples of different age groups were examined. Five groups of mice were used in the study; the first was injected with normal saline and considered as a negative control group, the second was injected with cystic form of non-irradiated Giardia lamblia and considered as a positive control group, whereas the other three groups were injected with gamma irradiated Giardia lamblia at three different doses 10, 15 and 25 rad respectively. Giardia lamblia was primarily cultivated in liver infusion agar for ten days to obtain the active phase. On the sixth day, the cystic phase was purified and standardized to be used in the infection of mice with or without the exposure of gamma rays. Mice showed high sensitivity to parasitic infestation, in the gamma non-irradiated and the irradiated with gamma 10 rad, and 15 rad irradiated groups which was 100%. The results expressed an excystation process of the depleted phases and the release of the feeder phases. The results of the three irradiated groups consisted of histopathological changes of the small, and the rectum by dissection after two weeks of infection, with intestine amputation lesions, as well as ulceration and inflammation of the inflammatory cells represented in small numbers of neutrophil, lymphocytes, and eosinophils. The presence of ulceration and fall of epithelial cells in the intestinal cavity has been shown, and different forms of the parasite have been observed. Mice which was injected with irradiated G lamblia at high dose (25 rad), not show and sensitivity to the challenge infection and no excystation of thy parasite had been done. After 2 wreaks, a comparison was achieved between all study groups in which no histopathological changes were noticed in the mice irradiated with dose of25 rad. After another two weeks, a challenge dose was given (un-attenuated G lamblia) and mice were dissected after another two weeks, no changes on the level of histopathology of intestinal tissue were noticed the results suggested that mice acquire an immunity against the parasite infection.


1998 ◽  
Vol 502 (1) ◽  
pp. 428-436 ◽  
Author(s):  
Igor V. Moskalenko ◽  
Werner Collmar ◽  
Volker Schonfelder

1996 ◽  
Vol 165 ◽  
pp. 313-319
Author(s):  
Mark H. Finger ◽  
Robert B. Wilson ◽  
B. Alan Harmon ◽  
William S. Paciesas

A “giant” outburst of A 0535+262, a transient X-ray binary pulsar, was observed in 1994 February and March with the Burst and Transient Source Experiment (BATSE) onboard the Compton Gamma-Ray Observatory. During the outburst power spectra of the hard X-ray flux contained a QPO-like component with a FWHM of approximately 50% of its center frequency. Over the course of the outburst the center frequency rose smoothly from 35 mHz to 70 mHz and then fell to below 40 mHz. We compare this QPO frequency with the neutron star spin-up rate, and discuss the observed correlation in terms of the beat frequency and Keplerian frequency QPO models in conjunction with the Ghosh-Lamb accretion torque model.


2021 ◽  
Vol 366 (4) ◽  
Author(s):  
Zhi-Ying Liu ◽  
Fu-Wen Zhang ◽  
Si-Yuan Zhu

2021 ◽  
Vol 4 (1) ◽  
Author(s):  
Koji Kato ◽  
Naoyuki Miyazaki ◽  
Tasuku Hamaguchi ◽  
Yoshiki Nakajima ◽  
Fusamichi Akita ◽  
...  

AbstractPhotosystem II (PSII) plays a key role in water-splitting and oxygen evolution. X-ray crystallography has revealed its atomic structure and some intermediate structures. However, these structures are in the crystalline state and its final state structure has not been solved. Here we analyzed the structure of PSII in solution at 1.95 Å resolution by single-particle cryo-electron microscopy (cryo-EM). The structure obtained is similar to the crystal structure, but a PsbY subunit was visible in the cryo-EM structure, indicating that it represents its physiological state more closely. Electron beam damage was observed at a high-dose in the regions that were easily affected by redox states, and reducing the beam dosage by reducing frames from 50 to 2 yielded a similar resolution but reduced the damage remarkably. This study will serve as a good indicator for determining damage-free cryo-EM structures of not only PSII but also all biological samples, especially redox-active metalloproteins.


Sign in / Sign up

Export Citation Format

Share Document