scholarly journals Influence of Erosive and Abrasive Cycling on Bonding of Different Adhesive Systems to Enamel: An In situ Study

2016 ◽  
Vol 27 (5) ◽  
pp. 548-555 ◽  
Author(s):  
Marina Ciccone Giacomini ◽  
◽  
Leslie Caroll Casas-Apayco ◽  
Camila Moreira Machado ◽  
Maria Cristina Carvalho de Almendra Freitas ◽  
...  

Abstract This study evaluated the impact of orange juice on the bond strength (BS) of dentin bonding systems (DBSs) to enamel surface after simulation with an in situ/ ex vivo erosive cycling. One hundred and ninety two bovine enamel fragments (4x4x2mm) were obtained and randomized regarding superficial microhardness and distributed to palatal devices for 8 volunteers, in three phases (one for each DBS), containing 8 blocks, which were, allocated in 4 pairs. Daily, these pairs were subjected extraorally to the following conditions: CONT- neither erosive nor abrasive challenge; ERO- erosive challenge only; ABR- abrasive challenge only and ERO + ABR- with erosive and abrasive challenges. Erosive cycles (immersion in orange juice, 3 times/day/5 min/5 days) or/and abrasive challenges (electric toothbrush, 3 times/day/1 min/5 days) were performed. After these cycles, all specimens were restored with the adhesive systems Adper Scotchbond Multi Purpose (MP), Adper Single Bond 2 (SB) or Clearfil SE Bond (SE), and the composite resin Filtek Z250. After 7 days, sticks (area ≅1 mm2) were obtained and subjected to the microtensile bond strength test (μTBS) at 0.5 mm/min. Data was statistically analyzed by ANOVA and Tukey tests (a=0.05). Failure modes were determined using a digital microscope (40´). DBS was the only statistical significant factor. SE was the unique DBS not affected in any challenge, whereas MP and SB performed according to the scenario. The adhesive and mixed failures were predominant in all groups. Overall performance suggested that BS to enamel after erosive /abrasive challenged by orange juice was not affected and it was material-dependent.

2016 ◽  
Vol 51 (1) ◽  
pp. 34-45 ◽  
Author(s):  
Susann Hertel ◽  
Sandra Pötschke ◽  
Sabine Basche ◽  
Judith Delius ◽  
Wiebke Hoth-Hannig ◽  
...  

Objectives: In the present in situ/ex vivo study the impact of tannic acid on the erosion-protective properties of the enamel pellicle was tested. Additionally, the antiadherent and antibacterial effects of tannic acid were evaluated. Methods: The pellicle was formed in situ on bovine enamel samples fixed on individual splints worn by 6 subjects. Following 1 min of pellicle formation the volunteers rinsed for 10 min with tannic acid. After further oral exposure for 19 min, 109 min, and 8 h overnight, respectively, slabs were incubated in HCl ex vivo (pH 2.0, 2.3, 3.0) over 120 s. Subsequently, kinetics of calcium and phosphate release were measured photometrically. Samples after a 1-min fluoride mouth rinse as well as enamel samples with and without a 30-min in situ pellicle served as controls. Antiadherent effects were evaluated after a 1-min rinse with tannic acid and oral exposure of the slabs overnight. DAPI (4′,6-diamidino-2-phenylindole) combined with concanavalin A staining and live/dead staining was used for fluorescence microscopic visualization and quantification of adherent bacteria and glucans. Modification of the pellicle's ultrastructure by tannic acid was evaluated by transmission electron microscopy (TEM). Results: Tannic acid significantly improved the erosion-protective properties of the pellicle in a pH-dependent manner. Bacterial adherence and glucan formation on enamel were significantly reduced after rinses with tannic acid as investigated by fluorescence microscopy. TEM imaging indicated that rinsing with tannic acid yielded a sustainable modification of the pellicle; it was distinctly more electron dense. Conclusion: Tannic acid offers an effective and sustainable approach for the prevention of caries and erosion.


Pharmaceutics ◽  
2020 ◽  
Vol 12 (6) ◽  
pp. 485 ◽  
Author(s):  
Usama A. Fahmy ◽  
Shaimaa M. Badr-Eldin ◽  
Osama A. A. Ahmed ◽  
Hibah M. Aldawsari ◽  
Singkome Tima ◽  
...  

Flibanserin (FLB) is a multifunctional serotonergic agent that was recently approved by the FDA for the oral treatment of premenopausal women with hypoactive sexual desire disorder. FLB is a centrally acting drug that has a low oral bioavailability of 33% owing to its exposure to the hepatic first-pass effect, as well as its pH-dependent solubility, which could be an obstacle hindering the drug dissolution and absorption via mucosal barriers. Thus, this work aimed at overcoming the aforementioned drawbacks and promoting the nose-to-brain delivery of FLB via the formulation of an intra-nasal in situ niosomal gel. The Box–Behnken design was employed to study the impact of Span® 85 concentration (X1), hydration time (X2), and pH of the hydrating buffer (X3) on the vesicle size and drug entrapment. The optimized formulation exhibited a spherical shape with a vesicular size of 46.35 nm and entrapment efficiency of 92.48%. The optimized FLB niosomes integrated into gellan gum-based in situ gel exhibited enhanced ex vivo permeation and improved plasma and brain concentrations after nasal administration in rats compared to raw FLB. These findings highlight the capability of the proposed intra-nasal FLB niosomal in situ gel to boost the drug bioavailability and to promote its direct delivery to the brain.


Author(s):  
Tubayesha Hassan ◽  
MH Sattar

As a means of regular practice in orthodontics and aesthetic dentistry, resin based adhesive systems are being used exclusively. Keeping up with the ever-increasing demand for aesthetic dental treatment all over the world, newer and more improved adhesive systems have been developed. However, regarding the comparison as to which bonding system performs better in clinical perspective, there is lack of existing scientific review articles. In this review, we tend to explore the conventional etch and rinse bonding system and the self-etch primer bonding system. The different tests to assess and compare bond strength between these two types of adhesives from various bibliography are discussed. The results of shear bond strength test, adhesive remnant index (ARI), enamel-adhesive interface using scanning electron microscope (SEM) and the effect of saliva contamination and time are discussed. Interestingly, each system has its strengths and weaknesses. In shear bond strength, self-etch bonding systems clearly exhibits less strength than conventional bonding systems. Resin tags into enamel surface are shorter in self-etch primer adhesives which results from milder etching to enamel compared to the conventional aid-etch and rinse adhesives. Contrarily, the irreversible changes to enamel surface is more aggressive in conventional acid-etching which states that self-etching systems are better according to the principles of minimal intervention dentistry. Ban J Orthod & Dentofac Orthop, April 2017; Vol-7 (1-2), P.20-26


2009 ◽  
Vol 79 (3) ◽  
pp. 564-570 ◽  
Author(s):  
Toshiya Endo ◽  
Rieko Ozoe ◽  
Koichi Shinkai ◽  
Makiko Aoyagi ◽  
Hiroomi Kurokawa ◽  
...  

Abstract Objective: To ascertain the effects of repeated bonding on the shear bond strength of orthodontic brackets bonded with a fluoride-releasing and -recharging adhesive system with a self-etching primer in comparison with two other types of adhesive system. Materials and Methods: A total of 48 premolars were collected and divided equally into three groups of 16. Each group was assigned one of three adhesive systems: Transbond XT, Transbond Plus, or a fluoride-releasing and -recharging adhesive system, Beauty Ortho Bond. Shear bond strength was measured 24 hours after bracket bonding, with the bonding/debonding procedures repeated twice after the first debonding. A universal testing machine was used to determine shear bond strengths, and bracket/adhesive failure modes were evaluated with the adhesive remnant index after each debonding. Results: At every debonding sequence, all of these three adhesive systems had a shear bond strength of 6 MPa, which is a minimum requirement for clinical use. Transbond XT and Transbond Plus had significantly higher mean shear bond strengths than did Beauty Ortho Bond at each debonding. No significant differences in mean bond strength were observed between the three debondings in each adhesive system. Bond failure at the enamel/adhesive interface occurred more frequently in Beauty Ortho Bond than in Transbond XT or Transbond Plus. Conclusions: The fluoride-releasing and -recharging adhesive system with the self-etching primer (Beauty Ortho Bond) had clinically sufficient shear bond strength in repeated bracket bonding; this finding can help orthodontists to decrease the risk of damage to enamel at debonding.


2015 ◽  
Vol 16 (5) ◽  
pp. 335-339 ◽  
Author(s):  
Zeeshan H Ahmad ◽  
Sukumaran Anil ◽  
Alaa El Araby ◽  
Mohammad D Al Amri

ABSTRACT Objective To evaluate the influence of Expasyl® gingival retraction paste on the shear bond strength of self-etch and total-etch adhesive systems. Materials and methods Twenty-four specimens of extracted, caries-free, sound human molars were used in this study. The molars were then cut vertically into halves through the buccal and lingual cusps. Forty-eight specimens were divided into four groups (total-etch, total-etch with Expasyl application, self-etch, self-etch with Expasyl application) and the shear bond strength was tested. Results Expasyl significantly reduced the shear bond strength of the self-etch and total-etch adhesive systems. The self-etch system showed relatively lower performance compared with the total-etch adhesive system. The shear bond strength values of the total-etch adhesive without Expasyl showed the highest bond strength (21.48 ± 2.89), while the self-etching group adhesive treated with Expasyl showed the lowest shear bond strength value (14.89 ± 1.81). Conclusion From the observations of this in vitro study, it can be concluded that the use of Expasyl® gingival retraction system can negatively affect bond strength of adhesives. The total-etch system showed better compatibility to the Expasyl gingival retraction system than the self-etch. How to cite this article Al Baker AMA, El Araby A, Al Amri MD, Sukumaran A. The Impact of Expasyl® Gingival Retraction Paste on the Bond Strength of Self-etch and Total-etch Systems. J Contemp Dent Pract 2015;16(5):335-339.


Blood ◽  
2016 ◽  
Vol 128 (22) ◽  
pp. 2453-2453
Author(s):  
Susana Brito dos Santos ◽  
Mark C. Allenby ◽  
Athanasios Mantalaris ◽  
Nicki Panoskaltsis

Abstract Reproduction of dynamic physiologic erythropoiesis in vitro requires a three-dimensional (3D) architecture, erythroblast-macrophage interactions and cytokines such as erythropoietin (EPO). The role of oxygen concentration gradients in this process is unclear. We have created a 3D bone marrow (BM) biomimicry using collagen-coated polyurethane scaffolds (5mm3) to expand cord blood mononuclear cells (CBMNCs) in a cytokine-free environment for 28 days (D). Addition of EPO to this system induces mature erythropoiesis. We hypothesised that physiologic concentrations of cytokines - stem cell factor (SCF) / EPO - and a hypoxia (H)/normoxia (N) schedule to mimic BM oxygen gradients would enhance erythropoiesis. CBMNCs were seeded (4x106 cells/scaffold) in 3D serum-free cultures supplemented with 10ng/mL SCF (D0-D28), and 100mU/mL EPO (D7-D28), with medium exchange every 3D. Three conditions were compared: N (20%), H (5%) and 2-step oxygenation HN (H D0-D7 and N thereafter). Erythroid maturation was monitored weekly by flow cytometry (CD45/CD71/CD235a) both in situ (i.e., in scaffolds) and in supernatant (S/N) cells. D0-7 H was more efficient in early induction of CD235a in the absence of exogenous EPO (H 13% vs N 8% CD45loCD71+CD235alo cells, p<0.05). This maturation profile was also observed in D10 S/N cells, in which CD45loCD71+CD235a+ cells were proportionately more in H (30%) and HN (27%) than in N (16%, p<0.05). By D14, N and HN stimulated the appearance of CD45-CD71+CD235a+ cells, whereas H maintained the CD45loCD71+CD235a-/lo phenotype. By D21, a CD45-CD71+CD235a+ mature population was clearly distinguished in all conditions, most notably in N (16%) and HN (21%) vs H (9%). At D28, more mature CD45-CD71loCD235a+ cells were observed in normoxia conditions, N 3% and HN 4%, vs H 0.3%. A renewed population of erythroid progenitors was also evident at this time (H 62%, N 51% and HN 46% CD45loCD71lo/+CD235a- cells). In order to assess the impact of H and N on erythroid gene transcription, we evaluated erythroid signatures by qRT-PCR. GATA-1 expression was detected from D7, highest for H at D14 (p<0.05), and decreased thereafter. GATA-2 expression was up-regulated only at D28, in particular in N (p<0.05), and correlated with emerging erythroid progenitors identified at this stage. At D14, EPOR expression was maximal, especially in HN (p<0.05), simultaneous with high pSTAT5 levels, suggesting activation of EPOR signalling. Also at D14, H upregulated γ-globin (p<0.05). By Western Blot, only H and HN still produced γ-globin whereas β-globin expression was clearly detected in all conditions by D28. In situ production of cytokines was evaluated by cytometric bead array in the exhausted media. IL-6, G-CSF, GM-CSF, IL-1, TNF-α and IL-17 were detected at higher concentrations during the first 7 days, declining to undetectable thereafter. IL-21 was not detected at any point. IL-3 was detected from D13, with highest expression in H (p<0.05, D22). VEGF was also expressed after D7, highest in H (p<0.05, D16 & D19), concurrent with HIF-1α up-regulation observed at D7 and D14. TNF-α was produced with variable intensity from D4. These data suggested that D7-D14 was a crucial period for culture dynamics, in particular for H and HN, with up-regulation of erythroid transcription factors, EPOR signalling, and endogenous cytokine production. BFU-E and CFU-E also dominated the first 14 days of culture. Scanning electron microscopy at D17 and D25 revealed niche-like structures in situ, which expressed STRO-1, osteopontin and vimentin at D19 by confocal immunofluorescent microscopy, indicative of an endogenous stromal cell microenvironment. CD68+ cells were also detected at D19 in proximity to CD71+ cells suggesting formation of erythroblastic islands. In this 3D ex vivo biomimicry using near-physiologic cytokine and oxygen conditions, H induced initial erythroid commitment and established an early erythroid progenitor population. N was required at later maturational stages and enhanced the γ-globin to β-globin switch. We identified D7-D14 as a crucial timeframe in this system wherein endogenous cytokine production as well as up-regulation of GATA-1, EPOR and HIF-1α was observed. We propose that a combined HN schedule in this 3D BM biomimicy may enable a more robust and physiologic culture platform to study normal and abnormal erythroid differentiation. Disclosures No relevant conflicts of interest to declare.


2006 ◽  
Vol 40 (3) ◽  
pp. 218-223 ◽  
Author(s):  
D. Rios ◽  
H.M. Honório ◽  
A.C. Magalhães ◽  
A.C.B. Delbem ◽  
M.A.A.M. Machado ◽  
...  
Keyword(s):  
Ex Vivo ◽  

2020 ◽  
Vol 14 (1) ◽  
pp. 408-415
Author(s):  
Isabella A. Gomes ◽  
Mário G. N. Gomes ◽  
Flávia L. B. Amaral ◽  
Fabiana M. G. França ◽  
Roberta T. Basting ◽  
...  

Objective: This study investigated whether different aging protocols have effects on the bond strength of total-etch and self-etch adhesive systems to dentin substrate. Methods: Molars were sectioned exposing the dentin, which was submitted to restorative procedures using two-step total-etch (ASB, Adper SingleBond2), two-step self-etch (CLF, Clearfil SEBond), or one-step self-etch (OPT, Optibond All-in-One) system and resin composite. The obtained blocks were sectioned to result in sticks to be submitted to bond strength and failure mode tests after 24h storage in distilled water (DW), or 180-day aging protocols in DW, artificial saliva (AS), citric acid (CA), or thermal cycling (TC). The types of failures were classified as adhesive, cohesive in dentin, cohesive in composite resin, and mixed. Data were analyzed using ANOVA followed by Tukey’s test (α=5%). The failure modes were descriptive under the relative frequencies form. Results: It was observed that ASB presented the higher bond strength(p<0.05), while CLF and OPT did not demonstrate differences between them(p>0.05) after 24h. The bond strength obtained with ASB significantly overcame that of OPT when stored in DW or AS for 180 days (p<0.001). In these storing mediums, ASB did not differ from CLF(p>0.05), while in CA or TC the values of CLF were significantly lower (p<0.001). In TC aging, the values presented by OPT did not differ from ASB(p>0.05), both of which had higher values than CLF(p<0.05). The predominant failure mode was adhesive. Conclusion: For the two-step total-etch and two-step self-etch adhesives, the influence of aging in AS and TC was equivalent to that of storage in DW. The most deleterious effects occurred in CA, a situation in which self-etch adhesives displayed worse performance than the conventional type.


Author(s):  
Omnia M. Sami ◽  
Essam A. Naguib ◽  
Rasha H. Afifi ◽  
Shaymaa M. Nagi

Abstract Objective Bonding to different dentin substrates influences resin composite restoration outcomes. This study investigated the influence of different adhesion protocols on the shear bond strength of universal adhesive systems to sound and artificial caries-affected dentin (CAD). Materials and Methods Occlusal enamel of 80 premolars were wet grinded to obtain flat midcoronal dentin. Specimens were equally divided according to the substrate condition: sound and CAD by subjecting to pH-cycling for 14 days. Each dentin substrate was bonded with the adhesive systems used in this study: Single Bond universal adhesive or Prime&Bond universal (applied either in etch-and-rinse or self-etch adhesion protocol). Adhesive systems were utilized according to manufacturers’ instructions, then resin composite was built up. Specimens were tested for shear bond strength. The data were analyzed by three-way analysis of variance, and failure modes were determined using stereomicroscope. Results There was no statistically significant difference between the two tested adhesive systems on artificially created CAD with different adhesion protocols. On sound dentin, Single Bond universal, either in the etch-and-rinse or self-etch adhesion protocols, revealed higher statistically significant shear bond strength mean values compared with CAD. Conclusion Single Bond universal adhesive in an etch-and-rinse adhesion protocol improved only bonding to sound dentin, while no added positive effect for the etching step with Prime&Bond universal adhesive was found when bonded to both sound and CAD substrates. The influence of CAD on the performance of the universal adhesives was material-dependent.


1995 ◽  
Vol 22 (3) ◽  
pp. 233-236 ◽  
Author(s):  
David R. Bearn ◽  
John C. Aird ◽  
John F. McCabe

Compared with conventional adhesive systems, adhesive precoated (APC) brackets are reported to have advantages in clinical use. The ex vivo bond strength to human premolar teeth of metallic and ceramic APC brackets was compared wi1h that of identical brackets bonded with Transbond® (3M Unitek) light cured orthodontic adhesive, and patterns of failure were examined. There was no significant difference (P>0·05) in mean bond strength between metallic brackets bonded with the two systems. Ceramic brackets bonded with Transbond® had significantly higher (P<0·05) mean bond strength and failure more normally occurred at the composite/enamel interface when compared with APC ceramic brackets and metallic brackets. Following debonding no enamel damage was observed with either APC or conventionally bonded ceramic brackets.


Sign in / Sign up

Export Citation Format

Share Document