scholarly journals Welfare and spatial distribution of noise levels in swine nursery

Author(s):  
Flavio A. Damasceno ◽  
Carlos E. A. Oliveira ◽  
Gabriel A. e S. Ferraz ◽  
João A. C. do Nascimento ◽  
Jairo A. O. Saraz ◽  
...  

ABSTRACT The aim of this study was to evaluate the welfare and spatial distribution of noise levels in a swine nursery during the first three weeks of animal’s life. The climatic conditions were evaluated through the dry-bulb temperature (Tdb), relative humidity (RH) and black globe temperature and humidity index (BGHI) and allowed us to observe that the heating system influenced the conditions in the environment, and the use of the air conditioning system did not guarantee animal’s comfort conditions. The analysis on the spatial distribution of noise levels was performed using geostatistics and demonstrated the occurrence of spatial variability inside the facilities. The highest frequencies of noise levels were concentrated between 60 and 70 dB, and the highest noise values were observed near the fans. The mean BGHI values were below the thermal comfort range for piglets in all systems tested.

2014 ◽  
Vol 18 (5) ◽  
pp. 1667-1672 ◽  
Author(s):  
Hai-Jun Li ◽  
Guang-Hui Zhou ◽  
An-Gui Li ◽  
Xu-Ge Li ◽  
Ya-Nan Li ◽  
...  

When the ordinary heat pump air conditioning system of a pure electric vehicle runs at ultra-low temperature, the discharge temperature of compressor will be too high and the heating capacity of the system will decay seriously, it will lead to inactivity of the heating system. In order to solve this problem, a modification is put forward, and an experiment is also designed. The experimental results show that in the same conditions, this new heating system increases more than 20% of the heating capacity; when the outside environment temperature is negative 20 degrees, the discharge temperature of compressor is below 60 degrees.


2010 ◽  
Vol 171-172 ◽  
pp. 215-218
Author(s):  
Hai Ying Wang ◽  
Song Tao Hu ◽  
Jia Ping Liu

Solar water heating system is used to supply hot water all-year-round for a new dormitory building. Flat solar energy collectors are mounted on the roof. The hot water tank and pumps are installed together with the air conditioning equipments in the plant room. Air cooled heat pump is used to provide cooling in summer, and high temperature water from boiler room (in old building) is used as heat source in winter. Usually auxiliary heating is necessary to improve the stability and reliability of solar water heating system. In this case, we take full use of the equipment of air conditioning system instead of electricity as auxiliary heating resources. In this paper, we introduced the design of the solar water heating system and the auxiliary heating method by air conditioning systems. The control strategies to fulfill all the functions and switch between different conditions are also introduced.


2012 ◽  
Vol 433-440 ◽  
pp. 5733-5738
Author(s):  
Jie Dong

As the improvement of the modern workshop’s demand for cool supply, heating system, how to effectively manage the air-conditioning equipments to satisfy the production skills for air-conditioning system has become an important subject for modern workshop design. This paper comes from the No.1 motorcar company’s project about the automatic air-conditioning system of the car spray-paint workshop. For many reasons, the conventional PID control is difficult to satisfy the car spray-paint production’s strictly demands of the temperature, after a careful research of the object, we utilize the principle of fuzzy PID adaptive control to design a fuzzy PID controller, then put it into the air-conditioning heater’s controlling, through the practice, we find the controller has a good robust property and realized a good control result.


2012 ◽  
Vol 204-208 ◽  
pp. 4274-4279
Author(s):  
Chao Yi Tan ◽  
Han Qing Wang ◽  
Hui Zhu

For the purpose of realizing non-dewfall condition of the radiant panels, low energy consumption and nice comfort of the freezing dehumidification-based radiant air-conditioning system, the design temperature and humidity of the room were figured out according to the mean comfort index of human body during the design. And in order to lower the energy consumption, the necessity of the reasonable load allocation between the dehumidification unit and the radiant unit was discussed by means of the calculation with the quasi heat-humidity-ratio line. As a result, much more precise design parameters were acquired through the approximation calculation. And it was proven to be a good design method by applying these parameters to the design of the reading rooms of the library. In the design example of the reading room, the load ratio between the dehumidification unit and the radiant unit was 48 to 52, and the recirculation air flow rate of the dehumidification unit was not less than 36.8% of the total air rate of the room.


2019 ◽  
pp. 49-53
Author(s):  
Євген Іванович Трушляков ◽  
Микола Іванович Радченко ◽  
Андрій Миколайович Радченко ◽  
Сергій Георгійович Фордуй ◽  
Сергій Анатолійович Кантор ◽  
...  

Maintaining the operation of refrigeration compressors in nominal or close modes by selecting a rational design thermal load and distributing it in response to the behavior of the current thermal load according to the current climatic conditions is one of the promising reserves for improving the energy efficiency of air conditioning systems, which implementation ensures maximum or close to it in the annual cooling production according to air conditioning duties. In general case, the total range of current thermal loads of any air-conditioning system includes a range of unstable loads caused by precooling of ambient air with significant fluctuations in the cooling capacity according to current climatic conditions, and a range of relatively stable cooling capacity expended for further lowering the air temperature from a certain threshold temperature to the final outlet temperature. If a range of stable thermal load can be provided within operating a conventional compressor in a mode close to nominal, then precooling the ambient air with significant fluctuations in thermal load requires adjusting the cooling capacity by using a variable speed compressor or using the excess of heat accumulated at reduced load. Such a stage principle of cooling ensures the operation of refrigerating machines matching the behavior of current thermal loads of any air-conditioning system, whether the central air conditioning system with ambient air procession in the central air conditioner or its combination with the local indoors recirculation air conditioning systems in the air-conditioning system. in essence, as combinations of subsystems – precooling of ambient air with the regulation of cooling capacity and subsequent cooling air to the mouth of the set point temperature under relatively stable thermal load.


2020 ◽  
Vol 35 (3) ◽  
pp. 388-394
Author(s):  
Fabiana Terezinha Leal de Morais ◽  
José Pinheiro Lopes Neto ◽  
Adriana Maria dos Santos ◽  
Patrício Gomes Leite ◽  
Raissa Gonçalves Cavalcanti

CONFORTO TÉRMICO E DESEMPENHO DE POEDEIRAS NA FASE INICIAL   FABIANA TEREZINHA LEAL DE MORAIS1, JOSÉ PINHEIRO LOPES NETO2, ADRIANA MARIA DOS SANTOS3, PATRÍCIO GOMES LEITE4, RAISSA GONÇALVES CAVALCANTI5   1Doutoranda em Engenharia Agrícola: Lacra, UFCG, Avenida Assis Chateaubriand, 101, Liberdade,58414-060, Campina Grande, Paraíba, Brasil. [email protected]. 2 Doutor em Engenharia Agrícola: Lacra, UFCG, R. Aprígio Veloso, 882 - Universitário, 58428-830, Campina Grande, Paraíba, [email protected]. 3 Mestra em Engenharia Agrícola: Lacra, UFCG, R. Alencar Pires de almeida, 07 – Centro, 58748-000, Água Branca, Paraíba, [email protected]. 4 Doutor em Engenharia Agrícola: Lacra, UFCG, R. Aprígio Veloso, 882 - Universitário, 58428-830, Campina Grande, Paraíba, [email protected] 5 Mestra em Engenharia Agrícola: Lacra, UFCG, R. Aprígio Veloso, 882 - Universitário, 58428-830, Campina Grande, Paraíba, [email protected].   RESUMO: Tendo em vista a importância do conforto térmico na avicultura de postura no Brasil, o objetivo geral destapesquisa foi avaliar o conforto térmico no galpão (pinteiro), localizado em uma granja comercial no município de Cuité (PB). A avaliação foi realizada com base nos dados de Índice da Temperatura do Globo Negro e Umidade (ITGU), avaliando o desempenho das pintainhas relacionado ao ganho de peso e as coletas de dados foram realizadas diariamente.Foi utilizado um galpão destinado para a fase de cria para aves da linhagem Lohmann LSL no período da terceira semana para desenvolvimento das aves, avaliando os valores de ITGU e comparando àqueles indicados pela literatura. Como resultados, observamos que foi possível manter as faixas de conforto térmicas bem próximas ao recomendado, e o ganho de peso mantiveram-se abaixo do indicado pelo manual da linhagem, os animais submetidos a condições térmicas adversas apresentaram menor ganho de peso.   Palavras-chave: ambiência, conforto térmico, ganho de peso.   THERMAL COMFORT AND POISER PERFORMANCE IN THE INITIAL PHASE (CRIA)   ABSTRACT: Considering the importance of thermal comfort in poultry farming in Brazil. The aim of this research was to evaluate the thermal comfort in the shed (pestle), located in a commercial farm in the municipality of Cuité - PB. The evaluation was performed based on the data of air temperature (ºC), relative humidity of the air (%), the black globe temperature for determination of the Black Globe Temperature and Humidity Index (ITGU). Weight gain on chicks and data collection were performed daily. The shed for the breeding phase of the Lohmann LSL line was used in the third week for bird development, evaluating the ITGU values and comparing to those indicated in the literature, we observed that it was possible to keep the thermal comfort bands very close to the recommended one, and the weight gain remained distant to that indicated by the lineage manual, the animals submitted to adverse thermal conditions showed less weight gain.   Keywords: ambience, thermal comfort, weight gain.