scholarly journals Comparison of human brain metabolite levels using 1H MRS at 1.5T and 3.0T

2013 ◽  
Vol 7 (2) ◽  
pp. 216-220 ◽  
Author(s):  
Fernando Fernandes Paiva ◽  
Maria Concepcion Garcia Otaduy ◽  
Ricardo de Oliveira-Souza ◽  
Jorge Moll ◽  
Ivanei Edson Bramati ◽  
...  

ABSTRACT Proton magnetic resonance spectroscopy (MRS) of the human brain has proven to be a useful technique in several neurological and psychiatric disorders and benefits from higher field scanners as signal intensity and spectral resolution are proportional to the magnetic field strength. Objective: To investigate the effects of the magnetic field on the measurement of brain metabolites in a typical routine clinical setting. Methods: Single voxel spectra were acquired from the posterior cingulate cortex in 26 healthy subjects. Each subject was scanned consecutively at 1.5T and 3.0T in a randomly distributed order. Results: SNR and peak width improvements were observed at higher fields. However, SNR improvement was lower than the theoretical two-fold improvement. Other than the values obtained for creatine (Cre) and myo-Inositol (mI), which were both higher at 3.0T, all metabolite concentrations obtained were roughly the same at both field strengths. All the metabolite concentrations were estimated with a Cramer Rao lower bounds (CRLB) lower than 15% of the calculated concentrations. Conclusions: Even though the present study supports the expected benefits of higher field strength for MRS, there are several factors that can lead to different quantitative results when comparing 1.5T to 3.0T MRS. Future comparative studies are necessary to refine the metabolite thresholds for early detection and quantification of distinct neurological and psychiatric disorders using 3.0T MRS.

1976 ◽  
Vol 32 ◽  
pp. 613-622
Author(s):  
I.A. Aslanov ◽  
Yu.S. Rustamov

SummaryMeasurements of the radial velocities and magnetic field strength of β CrB were carried out. It is shown that there is a variability with the rotation period different for various elements. The curve of the magnetic field variation measured from lines of 5 different elements: FeI, CrI, CrII, TiII, ScII and CaI has a complex shape specific for each element. This may be due to the presence of magnetic spots on the stellar surface. A comparison with the radial velocity curves suggests the presence of a least 4 spots of Ti and Cr coinciding with magnetic spots. A change of the magnetic field with optical depth is shown. The curve of the Heffvariation with the rotation period is given. A possibility of secular variations of the magnetic field is shown.


2021 ◽  
Vol 11 (10) ◽  
pp. 4683
Author(s):  
Areum Lee ◽  
Chinnasamy Veerakumar ◽  
Honghyun Cho

This paper discusses the forced convective heat transfer characteristics of water–ethylene glycol (EG)-based Fe3O4 nanofluid and Fe3O4–MWCNT hybrid nanofluid under the effect of a magnetic field. The results indicated that the convective heat transfer coefficient of magnetic nanofluids increased with an increase in the strength of the magnetic field. When the magnetic field strength was varied from 0 to 750 G, the maximum convective heat transfer coefficients were observed for the 0.2 wt% Fe3O4 and 0.1 wt% Fe3O4–MWNCT nanofluids, and the improvements were approximately 2.78% and 3.23%, respectively. The average pressure drops for 0.2 wt% Fe3O4 and 0.2 wt% Fe3O4–MWNCT nanofluids increased by about 4.73% and 5.23%, respectively. Owing to the extensive aggregation of nanoparticles by the external magnetic field, the heat transfer coefficient of the 0.1 wt% Fe3O4–MWNCT hybrid nanofluid was 5% higher than that of the 0.2 wt% Fe3O4 nanofluid. Therefore, the convective heat transfer can be enhanced by the dispersion stability of the nanoparticles and optimization of the magnetic field strength.


2001 ◽  
Vol 674 ◽  
Author(s):  
Norio Ota ◽  
Hiroyuki Awano ◽  
Manabu Tani ◽  
Susumu Imai

ABSTRACTMagnetic Amplifying Magneto-Optical System (MAMMOS) shows human brain like memory behavior. Magnetic field and laser power have threshold to recover the stored memory like the human response of remembering. MAMMOS also has a feature to amplify very small recorded signals like our recovery of memory, e.g. fifty years ago episode.By adding the meaningful information on the magnetic field pattern, we can get some correlation between our memory and external stimulation. Such scheme is named as “the Active readout MAMMOS” which is analogues to the human process of remembering the memory.If the applied field pattern and timing phase just coincide with stored information, there occurs the coherent amplification of MAMMOS signal. We can utilize such phenomena as the trigger of “Memory Association”.


2018 ◽  
Vol 615 ◽  
pp. A35 ◽  
Author(s):  
De-Fu Bu ◽  
Amin Mosallanezhad

Context. Observations indicate that wind can be generated in hot accretion flow. Wind generated from weakly magnetized accretion flow has been studied. However, the properties of wind generated from strongly magnetized hot accretion flow have not been studied. Aims. In this paper, we study the properties of wind generated from both weakly and strongly magnetized accretion flow. We focus on how the magnetic field strength affects the wind properties. Methods. We solve steady-state two-dimensional magnetohydrodynamic equations of black hole accretion in the presence of a largescale magnetic field. We assume self-similarity in radial direction. The magnetic field is assumed to be evenly symmetric with the equatorial plane. Results. We find that wind exists in both weakly and strongly magnetized accretion flows. When the magnetic field is weak (magnetic pressure is more than two orders of magnitude smaller than gas pressure), wind is driven by gas pressure gradient and centrifugal forces. When the magnetic field is strong (magnetic pressure is slightly smaller than gas pressure), wind is driven by gas pressure gradient and magnetic pressure gradient forces. The power of wind in the strongly magnetized case is just slightly larger than that in the weakly magnetized case. The power of wind lies in a range PW ~ 10−4–10−3 Ṁinc2, with Ṁin and c being mass inflow rate and speed of light, respectively. The possible role of wind in active galactic nuclei feedback is briefly discussed.


2008 ◽  
Vol 109 (2) ◽  
pp. 306-312 ◽  
Author(s):  
Andreas Stadlbauer ◽  
Michael Buchfelder ◽  
Christopher Nimsky ◽  
Wolfgang Saeger ◽  
Erich Salomonowitz ◽  
...  

Object The aim of this study was to correlate proton MR (1H-MR) spectroscopy data with histopathological and surgical findings of proliferation and hemorrhage in pituitary macroadenomas. Methods Quantitative 1H-MR spectroscopy was performed on a 1.5-T unit in 37 patients with pituitary macroadenomas. A point-resolved spectroscopy sequence (TR 2000 msec, TE 135 msec) with 128 averages and chemical shift selective pulses for water suppression was used. Voxel dimensions were adapted to ensure that the volume of interest was fully located within the lesion and to obtain optimal homogeneity of the magnetic field. In addition, water-unsuppressed spectra (16 averages) were acquired from the same volume of interest for eddy current correction, absolute quantification of metabolite signals, and determination of full width at half maximum of the unsuppressed water peak (FWHMwater). Metabolite concentrations of choline-containing compounds (Cho) were computed using the LCModel program and correlated with MIB-1 as a proliferative cell index from a tissue specimen. Results In 16 patients harboring macroadenomas without hemorrhage, there was a strong positive linear correlation between metabolite concentrations of Cho and the MIB-1 proliferative cell index (R = 0.819, p < 0.001). The metabolite concentrations of Cho ranged from 1.8 to 5.2 mM, and the FWHMwater was 4.4–11.7 Hz. Eleven patients had a hemorrhagic adenoma and showed no assignable metabolite concentration of Cho, and the FWHMwater was 13.4–24.4 Hz. In 10 patients the size of the lesion was too small (< 20 mm in 2 directions) for the acquisition of MR spectroscopy data. Conclusions Quantitative 1H-MR spectroscopy provided important information on the proliferative potential and hemorrhaging of pituitary macroadenomas. These data may be useful for noninvasive structural monitoring of pituitary macroadenomas. Differences in the FWHMwater could be explained by iron ions of hemosiderin, which lead to worsened homogeneity of the magnetic field.


Author(s):  
Chuncheng Yang ◽  
Zhong Liu ◽  
Xiangyu Pei ◽  
Cuiling Jin ◽  
Mengchun Yu ◽  
...  

Magnetorheological fluids (MRFs) based on amorphous Fe-Si-B alloy magnetic particles were prepared. The influence of annealing treatment on stability and rheological property of MRFs was investigated. The saturation magnetization ( Ms) of amorphous Fe-Si-B particles after annealing at 550°C is 131.5 emu/g, which is higher than that of amorphous Fe-Si-B particles without annealing. Moreover, the stability of MRF with annealed amorphous Fe-Si-B particles is better than that of MRF without annealed amorphous Fe-Si-B particles. Stearic acid at 3 wt% was added to the MRF2 to enhance the fluid stability to greater than 90%. In addition, the rheological properties demonstrate that the prepared amorphous particle MRF shows relatively strong magnetic responsiveness, especially when the magnetic field strength reaches 365 kA/m. As the magnetic field intensified, the yield stress increased dramatically and followed the Herschel-Bulkley model.


2003 ◽  
Vol 13 (12) ◽  
pp. 3783-3789 ◽  
Author(s):  
F. E. SMITH ◽  
P. LANGLEY ◽  
L. TRAHMS ◽  
U. STEINHOFF ◽  
J. P. BOURKE ◽  
...  

Multichannel magnetocardiography measures the magnetic field distribution of the human heart noninvasively from many sites over the body surface. Multichannel magnetocardiogram (MCG) analysis enables regional temporal differences in the distribution of cardiac magnetic field strength during depolarization and repolarization to be identified, allowing estimation of the global and local inhomogeneity of the cardiac activation process. The aim of this study was to compare the spatial distribution of cardiac magnetic field strength during ventricular depolarization and repolarization in both normal subjects and patients with cardiac abnormalities, obtaining amplitude measurements by magnetocardiography. MCGs were recorded at 49 sites over the heart from three normal subjects and two patients with inverted T-wave conditions. The magnetic field intensity during depolarization and repolarization was measured automatically for each channel and displayed spatially as contour maps. A Pearson correlation was used to determine the spatial relationship between the variables. For normal subjects, magnetic field strength maps during depolarization (R-wave) showed two asymmetric regions of magnetic field strength with a high positive value in the lower half of the chest and a high negative value above this. The regions of high R-wave amplitude corresponded spatially to concentrated asymmetric regions of high magnetic field strength during repolarization (T-wave). Pearson-r correlation coefficients of 0.7 (p<0.01), 0.8 (p<0.01) and 0.9 (p<0.01) were obtained from this analysis for the three normal subjects. A negative correlation coefficient of -0.7 (p<0.01) was obtained for one of the subjects with inverted T-wave abnormalities, suggesting similar but inverted magnetic field and current distributions to normal subjects. Even with the high correlation values in these four subjects, the MCG was able to identify differences in the distribution of magnetic field strength, with a shift in the T-wave relative to the R-wave. The measurement of cardiac magnetic field distribution during depolarization and repolarization of normal subjects and patients with clinical abnormalities should enable the improvement of theoretical models for the explanation of the cardiac depolarization and repolarization processes.


2019 ◽  
Vol 21 (25) ◽  
pp. 13696-13705 ◽  
Author(s):  
Alexey S. Kiryutin ◽  
Bogdan A. Rodin ◽  
Alexandra V. Yurkovskaya ◽  
Konstantin L. Ivanov ◽  
Dennis Kurzbach ◽  
...  

The magnetic field strength during sample transfer in dissolution dynamic nuclear polarization influences the resulting spectra.


1972 ◽  
Vol 50 (2) ◽  
pp. 116-118 ◽  
Author(s):  
C. W. T. Chien ◽  
R. E. Bardsley ◽  
F. W. Dalby

Zero-field level-crossing techniques have been used to measure some upper-state lifetimes of the helium atom. The half-widths of curves obtained by plotting the polarization against the magnetic field strength for the n1D–21D transitions yielded lifetimes of 2.03 × 10−8 s for the 31D state, 3.36 × 10−8 s for the 41D state, and 7.44 × 10−8 s for the 51D state. Collision cross sections for these 1D levels were also determined.


Sign in / Sign up

Export Citation Format

Share Document