scholarly journals Effects of Air Temperature Step Changes on Thermal Perception and Perceived Arousal in an Actual Environment under Hot-Humid Climate Conditions

2019 ◽  
Vol 22 (1) ◽  
pp. 7-15
Author(s):  
Etika Vidyarini ◽  
Takafumi Maeda
2021 ◽  
Vol 2021 ◽  
pp. 1-12
Author(s):  
Zuzhong Li ◽  
Yayun Zhang ◽  
Chunguang Fa ◽  
Xiaoming Zou ◽  
Haiwei Xie ◽  
...  

Temperature is known to be one of the most important factors affecting the design and performance of asphalt concrete pavement. The distresses of asphalt overlay are closely related to its temperature, particularly in Guangxi, a hot-humid-climate region in China. This research is to analyze the impact of meteorological factors on temperature at 2 cm depth in asphalt overlay by ReliefF algorithm and also obtain the temperature prediction model using MATLAB. Two test sites were installed to monitor the temperatures at different pavement depths from 2014 to 2016; meanwhile, the meteorological data (including air temperature, solar radiation, wind speed, and relative humidity) were collected from the two meteorological stations. It has been found that the temperature at 2 cm depth experiences greater temperature variation, and the maximum and minimum temperatures of asphalt overlay, respectively, occur at 2 cm depth and on the surface. Besides, the results of ReliefF algorithm have also shown that the temperature at 2 cm depth is affected significantly by solar radiation, air temperature, wind speed, and the relative humidity. Based on these analyses, the prediction model of maximum temperature at 2 cm depth is developed using statistical regression. Moreover, the data collected in 2017 are used to validate the accuracy of the model. Compared with the existing models, the developed model was confirmed to be more effective for temperature prediction in hot-humid region. In addition, the analysis of rutting depth and overlay deformation for the two test sections with different materials is done, and the results have shown that reasonable structure and materials of asphalt overlay are vital to promote the high-temperature antideforming capability of pavement.


2017 ◽  
Vol 46 (1) ◽  
pp. 3-25
Author(s):  
Athanas Chatalov

Quartz-rich sandstones and ironstone crusts occur in the lowermost part of the Upper Triassic Moesian Group exposed in the western Balkanides. On the basis of performed field studies, micropetrography, X-ray diffraction, and major-element chemistry, these deposits are defined as first-cycle quartz arenites and laterites, respectively. The former were deposited in an alluvial environment, while the latter developed in gravel-dominated fluvial sediments. The main control on their formation was warm to hot humid climate conditions combined with low relief, quiescent tectonic setting, mixed source area, and slow sedimentation rate. The decreasing compositional maturity of the sandstones forming the Glavatsi Member (quartz arenites→feldsarenites→litharenites), the disappearance of the lateritic crusts upwards in the continental succession, and the presence of thick overlying fluvial and playa deposits in the Komshtitsa Formation (or Chelyustnitsa Formation) reflect gradual transition from humid to subhumid climate, and then to persistent semi-arid climate regime. This irreversible trend correlates with other Upper Triassic strata deposited in the Western Tethys realm and adjacent areas. The coeval formation of quartz arenites and laterites must have been related to the most distinctive climate change during the Triassic, i.e., the global Carnian Humid Episode. The new results and interpretations appear to be the first geological record for the effect of pronounced mid-Carnian humidity reported from Eastern Europe. They also present indirect sedimentological evidence for the stratigraphical range of the Moesian Group in NW Bulgaria.


2009 ◽  
Vol 4 (2) ◽  
pp. 150-157 ◽  
Author(s):  
Vijayalaxmi J ◽  
S.P Sekar

In a hot-humid tropical climate, indoor thermal performance can be enhanced by comfort ventilation. Indoor ventilation depends upon building opening size. But risks involved in providing openings include ingress of mosquitoes and insects which thrive in the tropical climate. A practical and prevalent option to prevent insects in ventilated dwellings of the tropical, hot-humid city of Chennai, India is through the use of fly screens. Fly screens, when used over openings, prevent a certain quantum of solar radiation and wind from entering inside the rooms. Reduced direct solar radiation prevents the indoors from heating up, while reduced wind movement prevents the cross ventilation. Therefore, it is important to know the indoor thermal performance of ventilated rooms in the presence of fly screens with changing opening sizes. The criterion to evaluate indoor thermal performance in this paper is indoor air temperature. The aim of this research is to investigate the influence of fly screens on openings with varying sizes, in a naturally ventilated dwelling in the hot-humid climate of Chennai, India, during the summer period. The results of the study show that fly screens raise the indoor air temperature when openings are in the range of 100% to 35% of the room floor area. There is no significant change in the indoor air temperature when the opening sizes are less than 30% of the room floor area.


Author(s):  
Christian A. Njoku ◽  
Ikenna Orisakwe ◽  
Vincent N. Ojeh

The human biometeorological conditions at mid-afternoon during 12 months of 2012 in the city of Minna North-Central Nigeria have been evaluated based on energy budget indices (UTCI and PET) using climate parameters -air temperature, relative humidity, wind speed and solar radiation) observed at 15:00LST as input into the Rayman model. Air temperature demonstrated strongest significant correlation coefficient (r) with UTCI and PET (r= 0.91, r= 0.93) (P<0.0001) while windspeed show weakest association with them(r=-0.10, r=-0.20) (P<0.03, P<0.001) respectively. March and August were characterized by peak and slightest monthly thermal stress conditions according to both indices. The correlation coefficient between both indices was significantly (P<0.0001) very strong (r=0.98) and more noticeable for equivalent temperatures in strong stress thresholds (UTCI>=32°C, PET>=35°C), which shows that both indices can be used indifferently in warm climates. However, during May to October, UTCI better expressed warm conditions than PET mainly due to the difference in the definition of reference environment for both indices; this study is relevant to the urban sightseeing industry as tourists would most likely opt for a period of lesser thermal discomfort.


2021 ◽  
Vol 2042 (1) ◽  
pp. 012062
Author(s):  
Vajreshwari Patil ◽  
Maite Bizcarguenaga ◽  
Katherine Lieberknecht ◽  
Juliana Felkner

Abstract In this study we examine the summer cooling effects of trees and green facades on reducing urban heat island effects. Using ENVI-met model simulations, we investigate the influence of added greenery on the surface and ambient air temperature and its role on air fluctuations in the hot humid climate of Austin, TX, at pedestrian height. Under the specific conditions considered in this model, the results show the combination of trees and green facades has a greater cooling effect. Added greenery to the building mostly impacts the building's surface temperature during the hottest hours of the day, registering a maximum surface temperature reduction of 20.33°C. Simulations also show a maximum overall potential air temperature reduction of 0.54°C, and a maximum potential air temperature cooling effect near the building of 0.91°C. Future research should be conducted to address this study's limitations. Nevertheless, these findings can provide architects, designers, planners, and policymakers with a better understanding of the many benefits trees and green facades have, and provide them with the necessary tools to implement new solutions across sectors and scales to reduce the impacts urban areas have on the environment and provide a better living for all.


2018 ◽  
Vol 34 ◽  
pp. 02053
Author(s):  
Esra’a Sh. Abbaas ◽  
Ala’eddin A. Saif ◽  
MAC Munaaim ◽  
Md. Azree Othuman Mydin

The influence of courtyard on the thermal performance of Development Department office building in University Malaysia Perlis (UniMAP, Pauh Putra campus) is investigated through simulation study for the effect of ventilation on indoor air temperature and relative humidity of the building. The study is carried out using EnergyPlus simulator interface within OpenStudio and SketchUp plug in software to measure both of air temperature and relative humidity hourly on 21 April 2017 as a design day. The results show that the ventilation through the windows facing the courtyard has sufficient effect on reducing the air temperature compared to the ventilation through external windows since natural ventilation is highly effective on driving the indoor warm air out to courtyard. In addition, the relative humidity is reduced due to ventilation since the courtyard has high ability to remove or dilute indoor airborne pollutants coming from indoor sources. This indicates that the presence of courtyard is highly influential on thermal performance of the building.


2020 ◽  
Vol 12 (7) ◽  
pp. 2591
Author(s):  
Jin Wei ◽  
Fangsi Yu ◽  
Haixiu Liang ◽  
Maohui Luo

Due to the different types of courtyards in vertical courtyard system (VCS), their impacts on thermal performance in office buildings may vary. To better understand this issue, this paper investigates the thermal performance impact of three typical vertical courtyards. A field case study was conducted in VCSs during two typical extreme hot days under hot-humid climate conditions. The results show that the vertical courtyards have significant cooling effects under hot-humid climatic conditions. Via testing on linear, integrated, and rooftop courtyard with fusion layout, the fusion one has an obviously positive impact on air temperature reduction (4.3 °C). Compared with the linear and integrated courtyards, the maximum air temperature difference of fusion layout is around 1.6 °C. The thermal radiation environment of the fusion layout was better than that of the other two (linear and integrated). Besides, the surface temperature of the pavements (wood panel) in the vertical courtyards can reach 47 °C, while the vegetation can lower it by 8 °C under the same weather conditions. These findings show that the courtyard with fusion layout is more suitable for extreme hot weather conditions.


2020 ◽  
Vol 12 (14) ◽  
pp. 5741 ◽  
Author(s):  
Sheikh Ahmad Zaki ◽  
Siti Wan Syahidah ◽  
Mohd Fairuz Shahidan ◽  
Mardiana Idayu Ahmad ◽  
Fitri Yakub ◽  
...  

This study investigated the variation of outdoor air temperature in the shaded area covered by buildings in an urban university campus in Malaysia. In-situ field measurements were conducted to measure the distribution of outdoor air temperature at eight different locations for seven days. Meanwhile, the building-induced shadows were generated using the AutoCAD Revit software to investigate the air temperature change. The study used four urban morphological parameters namely building to greenery ratio, sky view factor (SVF), and height-to-street width (H/W) ratio. The relationship between building-induced shadow and outdoor air temperature (Tout) obtained from the in-situ measurement was investigated. The results showed that the building-induced shadows could lower air temperature. It can be noted that a high ratio of building to greenery resulted in a higher air temperature. In contrast, the area with a low SVF value due to the combination of prolonged shading by buildings and trees had a lower air temperature. Thus, the area with a high building ratio, low greenery ratio, higher SVF value, and low H/W ratio potentially has a higher outdoor air temperature. Conclusively, combination of building shading created by appropriate ratio of building morphology and sufficient greenery able to improve the microclimate of a campus area.


2020 ◽  
Vol 22 ◽  
pp. 100762
Author(s):  
Zeyad Amin Al-Absi ◽  
Mohd Isa Mohd Hafizal ◽  
Mazran Ismail ◽  
Ahmad Mardiana ◽  
Azhar Ghazali

2020 ◽  
Vol 103 ◽  
pp. 71-81
Author(s):  
Akhlish Diinal Aziiz ◽  
M. Donny Koerniawan ◽  
Risa Kawakami ◽  
Hishashi Hasebe ◽  
Vebryan Rhamadana

This research works’ objective is to observe the workers’ productivity by measuring the physiology and psychology based on the environment provided — the multivariate analysis presented to review the value of the significant data using JMP 11. Analysis of Variants and Bivariate Analysis then used to understand the cause-effect of the result gained. Result from of physiology that record the subject skin temperature and heart rate first analyze to break down the relationship between the environment to the body. Psychology test relating to the overall environment and their bodily feeling is questioned to the subject. The result then is analyzed using a scatter diagram and boxplot to observe its consistency. Four levels of air temperature and three levels of humidity were set in the room designed as a climate chamber for the respondent of who role as workers. The physiology result shows that the skin temperature and heart rate was the most significance that reacts to the air temperature, following up by the concentration level. Meanwhile, the physiology and psychology test consistently reveal that tropical natives highly react to hot temperature than colder temperature by agreeing to the label of uncomforted or dissatisfied and inform that the air temperature around 22°C. to 28°C. is suited for working productivity in the office in a hot-humid climate.


Sign in / Sign up

Export Citation Format

Share Document