scholarly journals Emission load of car service interiors

2016 ◽  
Vol 62 (No. 3) ◽  
pp. 122-128
Author(s):  
I. Vitázek ◽  
D. Michalíková ◽  
B. Vitázková ◽  
J. Klúčik

Car service centres are specific in terms of production of pollutants. The aim of the paper is to assess the quality of indoor environment of car service interiors with respect to the safe range of oxocarbon emission limits, concentration of gaseous and solid aerosols of selected chemical pollutants and occupational noise exposure. Measurements of concentration and exposure time indicated that the permitted limits were kept. CO concentration reached values in the range from 0 to 10 ppm, CO<sub>2</sub> concentration was observed in the range from 493 to 967 ppm. Concentration of solid aerosol of polyester bitumen reached the maximum value of 0.37 mg/m<sup>3</sup>, while for gaseous aerosol (e.g. toluene) it equalled 8.114 mg/m<sup>3</sup>. Measurements of chemical factors were carried out and evaluated by companies with appropriate accreditation. Occupational Exposure Limits (OELs) were higher in case of all selected substances. OEL was not demonstrably exceeded at any chemical factor. Noise emissions approached the limit values; therefore, hearing protection is required.

2020 ◽  
Vol 305 ◽  
pp. 00044
Author(s):  
Sorin Simion ◽  
Alexandru Simion ◽  
Izabella Kovacs ◽  
Vlad Lautaru

A general problem in the vicinity of industrial compressors is the noise generated in the working environment by their operation. A large number of workers suffer from hearing problems caused by exposure to high levels of noise in the workplace. Thus, legal provisions regulating occupational noise exposure aim to reduce the risk of hearing loss by reducing noise level, the most effective measures being those applied directly to the noise source combined with the use of hearing protection. Quantification of noise exposure level and mitigation of occupational hazards generated by it at each workplace is required in order to prevent accidents and occupational diseases. The current paper analyses how noise generated by industrial compressors influences worker’s activity. Prevention of noise exposure must be based on noise level measurements. In this sense, the purpose of the paper is to analyse noise measurements performed at a compressor hall and to compare the values obtained with limit values set by in force legislation, in order to apply the best technical organizational methods for lowering noise exposure and increasing acoustic comfort in order to improve working conditions of those working in the compressor hall.


2015 ◽  
Vol 16 (1) ◽  
pp. 15-24
Author(s):  
Vance Gunnell ◽  
Jeff Larsen

Hearing thresholds and distortion product otoacoustic emissions were measured for teachers of vocal performance who were gathered for a national conference. Results showed mean audiometric thresholds to be consistent with noise induced hearing loss, more than what would be expected with normal aging. Years of instruction and age were considered as factors in the hearing loss observed. It was concluded that hearing conservation should be initiated with this group to help raise awareness and protect them from hearing loss due to occupational noise exposure.


2018 ◽  
Vol 28 (4) ◽  
pp. 1329-1333
Author(s):  
Miodrag Šmelcerović

The protection of the environment and people’s health from negative influences of the pollution of air as a medium of the environment requires constant observing of the air quality in accordance with international standards, the analysis of emission and imission of polluting matters in the air, and their connection with the sources of pollution. Having in mind the series of laws and delegated legislations which define the field of air pollution, it is necessary to closely observe these long-term processes, discovering cause-and-effect relationships between the activities of anthropogenic sources of emission of polluting matters and the level of air degradation. The relevant evaluation of the air quality of a certain area can be conducted if the level of concentration of polluting matters characteristic for the pollution sources of this area is observed in a longer period of time. The data obtained by the observation of the air pollution are the basis for creation of the recovery program of a certain area. Vranje is a town in South Serbia where there is a bigger number of anthropogenic pollution sources that can significantly diminish the air quality. The cause-and-effect relationship of the anthropogenic sources of pollution is conducted related to the analysis of systematized data which are in the relevant data base of the authorized institution The Institute of Public Health Vranje, for the time period between the year of 2012. and 2017. By the analysis of data of imission concentrations of typical polluting matters, the dominant polluting matters were determined on the territory of the town of Vranje, the ones that are the causers of the biggest air pollution and the risk for people’s health. Analysis of the concentration of soot, sulfur dioxide and nitrogen oxides indicates their presence in the air of Vranje town area in concentrations that do not exceed the permitted limit values annually. The greatest pollution is caused by the soot content in the air, especially in the winter period when the highest number of days with the values above the limit was registered. By perceiving the influence of natural and anthropogenic factors, it is clear that the concentration of polluting matters can be decreased only by establishing control over anthropogenic sources of pollution, and thus it can be contributed to the improvement of the air quality of this urban environment.


2021 ◽  
Vol 685 (1) ◽  
pp. 012002
Author(s):  
Afiqah Kamaruzzaman ◽  
Tengku Azmina Ibrahim ◽  
Fazrul Razman Sulaiman ◽  
Ismaniza Ismail

2015 ◽  
Vol 669 ◽  
pp. 150-157
Author(s):  
Peter Michal ◽  
Alena Vagaská ◽  
Miroslav Gombár

Paper tracks experimentally confirmed relationship between chemical composition of electrolyte and resulting surface finish quality of created oxide layer during the process of anodic oxidation of aluminium. Examined chemical factors were: concentrations of sulphuric acid, oxalic acid, boric acid and sodium chloride. Aggressive effects of electrolyte were chosen as indicator of resulting layer quality – presence and extent of etching of used substrate sample.


Sign in / Sign up

Export Citation Format

Share Document