PREPARATION OF WATER FOR THE OPERATION OF BOILER AND HEATING NETWORKS IN THE DISTRICTS OF THE CITY OF SAMARA, CITIES AND TOWNS OF THE SAMARA REGION

2018 ◽  
Vol 8 (1) ◽  
pp. 50-53
Author(s):  
Svetlana A. MINKINA ◽  
Larisa L. NEGODA ◽  
Tatyana S. KURMAYEVA

The problem of water quality is considered for the operation of boiler and heating networks in the example of the districts of the city of Samara, as well as cities and towns of the Samara region. The results of the chemical analysis of natural waters in the areas of the city of Samara, cities and towns of the Samara region are presented. As the main quality indicators in the choice of water preparation methods, the total hardness, carbonate hardness, the dry residue of the initial water, the hydrogen index are considered. Based on water quality indicators, recommendations are given on the choice of water treatment methods in boiler rooms for boilers of various types and depending on their thermal capacity. Att ention is focused on the correct choice of the softening method depending on the water quality indicators.

Author(s):  
S. I. Kravets ◽  
O. V. Krushelnytska ◽  
N. V. Poliukhovych

The growth and development of fish depend on the physicochemical properties of water, such as temperature, turbidity, concentration of hydrogen ions (pH), dissolved oxygen, total alkalinity, total hardness, nitrates, nitrites, etc. The article presents data on the hydrochemical regime of growing ponds of the farm “Rudnyky” of Lviv region. Studies have shown that the water quality indicators of growing ponds during the growing season are within the normative values and the water is suitable for fish farming. In the breeding ponds of the Rudnyky fishery, the water quality indicators fluctuated within the following limits, namely: the hydrogen index (pH) was within the maximum permissible concentrations (6.7–8.0). The content of dissolved oxygen in the water during the growing season was within normal limits (6.5 to 7.8 mg/l) and fully met the requirements for carp fish ponds, the alkalinity of the water was average and varied between 2.40 and 3.20 mg-eq/l, permanganate and dichromate oxidation varied slightly – 8.6–15.45 mgO/l and 25.6–40.50 mgO/l, which corresponds to the normative indicators for fish farming. The concentration of ammonium nitrogen (NH4+) in the growing ponds of the farm averaged 0.008–0,520 mg N/l, the content of nitrites and nitrates was 0.002–0.100 mg N/l and 0.060–0,520 mg N/l, respectively. The average concentration ranged from 0.10 mg P/l to 0.40 mg P/l of mineral phosphorus (PO4-3), which did not exceed the normative values. The amount of total iron in the water of the pond did not have high values, averaged 0.10–0.38 mg Fe/l, which was within the maximum allowable concentrations. The values of total hardness of water were determined as moderately hard and were in the range of 2.9–5.0 mg-eq/l. The salt composition of pond water was characterized by total mineralization, the ratio of ions and the content of chlorides, sulfates, bicarbonates. During the study period, the content of chlorides (Cl-) sulfates (SO4 2-); hydrocarbons (HCO3-), did not exceed the maximum allowable concentration. Among the cations in the pond water, calcium ions (Ca2+ ) predominated, their content averaged 28.2–80 mg Ca/l. In the studied pond, the concentration of magnesium (Mg2+) reached average values – 6.8–20.0 mg/l. The total mineralization of water was 300.4–440.4 mg/l. By the nature of the ionic composition, the water of the growing ponds belongs to the hydrocarbonate composition of the calcium group.


TAPPI Journal ◽  
2009 ◽  
Vol 8 (3) ◽  
pp. 14-20 ◽  
Author(s):  
YUAN-SHING PERNG ◽  
EUGENE I-CHEN WANG ◽  
SHIH-TSUNG YU ◽  
AN-YI CHANG

Trends toward closure of white water recirculation loops in papermaking often lead to a need for system modifications. We conducted a pilot-scale study using pulsed electrocoagulation technology to treat the effluent of an old corrugated containerboard (OCC)-based paper mill in order to evaluate its treatment performance. The operating variables were a current density of 0–240 A/m2, a hydraulic retention time (HRT) of 8–16 min, and a coagulant (anionic polyacrylamide) dosage of 0–22 mg/L. Water quality indicators investigated were electrical con-ductivity, suspended solids (SS), chemical oxygen demand (COD), and true color. The results were encouraging. Under the operating conditions without coagulant addition, the highest removals for conductivity, SS, COD, and true color were 39.8%, 85.7%, 70.5%, and 97.1%, respectively (with an HRT of 16 min). The use of a coagulant enhanced the removal of both conductivity and COD. With an optimal dosage of 20 mg/L and a shortened HRT of 10 min, the highest removal achieved for the four water quality indicators were 37.7%, 88.7%, 74.2%, and 91.7%, respectively. The water qualities thus attained should be adequate to allow reuse of a substantial portion of the treated effluent as process water makeup in papermaking.


2018 ◽  
Vol 69 (10) ◽  
pp. 2940-2952 ◽  
Author(s):  
Martina Zelenakova ◽  
Pavol Purcz ◽  
Radu Daniel Pintilii ◽  
Peter Blistan ◽  
Petr Hlustik ◽  
...  

Evaluating trends in water quality indicators is a crucial issue in integrated water resource management in any country. In this study eight chemical and physical water quality indicators were analysed in seven river profiles in the River Laborec in eastern Slovakia. The analysed water quality parameters were biochemical oxygen demand (BOD5), chemical oxygen demand (CODCr), pH, temperature (t), ammonium nitrogen (NH4+-N), nitrite nitrogen (NO2--N), nitrate nitrogen (NO3--N), and total phosphorus (TP). Data from the monitored indicators were provided by the Ko�ice branch of the Slovakian Water Management Company, over a period of 15 years from 1999 to 2013. Mann�Kendall non-parametric statistical test was used for the trend analysis. Biochemical and chemical oxygen demand, ammonium and nitrite nitrogen content exhibit decreasing trends in the River Laborec. Decreasing agricultural activity in the area has had a significant impact on the trends in these parameters. However, NO2--N was the significant parameter of water quality because it mostly exceeds the limit value set in Slovak legislation, Regulation No. 269/2010 Coll. In addition, water temperature revealed an increasing trend which could be caused by global increase in air temperature. These results indicate that human activity significantly impacts the water quality.


Hydrology ◽  
2021 ◽  
Vol 8 (2) ◽  
pp. 86
Author(s):  
Angeliki Mentzafou ◽  
George Varlas ◽  
Anastasios Papadopoulos ◽  
Georgios Poulis ◽  
Elias Dimitriou

Water resources, especially riverine ecosystems, are globally under qualitative and quantitative degradation due to human-imposed pressures. High-temporal-resolution data obtained from automatic stations can provide insights into the processes that link catchment hydrology and streamwater chemistry. The scope of this paper was to investigate the statistical behavior of high-frequency measurements at sites with known hydromorphological and pollution pressures. For this purpose, hourly time series of water levels and key water quality indicators (temperature, electric conductivity, and dissolved oxygen concentrations) collected from four automatic monitoring stations under different hydromorphological conditions and pollution pressures were statistically elaborated. Based on the results, the hydromorphological conditions and pollution pressures of each station were confirmed to be reflected in the results of the statistical analysis performed. It was proven that the comparative use of the statistics and patterns of the water level and quality high-frequency time series could be used in the interpretation of the current site status as well as allowing the detection of possible changes. This approach can be used as a tool for the definition of thresholds, and will contribute to the design of management and restoration measures for the most impacted areas.


Author(s):  
Petra Nováková

The aim of the work was to elaborate and evaluate the water quality of water reservoir Vranov nad Dyjí. Fresh water was sampled in five different locations of the reservoir (three important tributaries, dam and water captation locality). Ten, the most essential water quality indicators were selected. From the point of view of water quality indicators complexity the most integrated samples were taken in the water captation locality (period 1984 – 2002). At other locations, there were missing dates from the eightieth, but their volume was sufficient for statistical processing.Correlation analyses for the individual locations and dimensions were done as so as determination coefficients for all localities during the time period of 1994 – 2002. The results demonstrate very good allocation of the water captation from the point of view of the water flow.Multiples and factor analysis was done for the period of 1984 – 2002 in the locality Jelení zátoka where the object of water captation is situated. The results of the analysis are nine factors, which influence the water quality of the reservoir. From the point of view of the importance three factors were interpreted.The analyses and results are part of my Ph.D. thesis. The results will be used for other evaluations of the water quality in the reservoir and tributaries, for activities in the catchment’s area and for proposal processing other zones of second level of protected areas.


2021 ◽  
Vol 25 (3) ◽  
pp. 34-43
Author(s):  
Tamarah A. Adnan ◽  
◽  
Eman A. Mohammed ◽  
Abdul-Sahib T. Al-Madhhachi ◽  
◽  
...  

Tigris River is the only potable source in Baghdad city therefor many water treatment plants were built on the banks such as Al-Karkh, Sharq Dijla, Al-Sadr, Al-Wathba, Al-Karama, AlQadisia, Al-Dora, Al-Wahda, and Al-Rashed project. Tigris River suffers from the pollution that comes from various sources such as Industry, domestic sanitation, and farming activities therefore several indices were used to calculate water quality within Baghdad to convert physicochemical parameters of water to a single value that represents the river status (good, bad, very bad, etc..).The aim of this review paper to show the results of previous studies about the water quality for the Baghdad region. Most results showed that water quality was good in the north of the city of Baghdad and bad in the south of Baghdad. The deterioration of water quality was due to many reasons such as the discharge of wastewater directly into the river without pretreatment, increase in (Electic conductivity, Turbidity, and total suspended solids, total hardness, Iron ion, the fecal coliform)concentrations, and Climate change, therefore, Tigris River needs intensive treatment before using by humans.


Sign in / Sign up

Export Citation Format

Share Document