scholarly journals Parkinsonism management issues in a patient with exhausted subthalamic deep brain stimulation battery, stricken by severe acute respiratory syndrome coronavirus 2

Author(s):  
Seyed Amir Hassan Habibi ◽  
Luigi Romito ◽  
Oldooz Aloosh ◽  
Mohammad Rohani ◽  
Fatemeh Moghadas ◽  
...  

Background: Nowadays, many neurological conditions, including Parkinson’s disease (PD), are treated with deep brain stimulation (DBS). Life-threatening consequences can occur from DBS hardware failure or sudden implantable pulse generator (IPG) battery depletion. This issue may potentially worsen in concomitance with medical or infectious conditions, requiring stronger emergency management. Methods: We present here a 58 year-old PD patient with DBS, whose IPG replacement surgery was complicated by severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and we report management of this patient along with recommendations for patients with similar situation. Results: As the newly-emerged coronavirus disease 2019 (COVID-19) is now announced to be pandemic, new protocols and specific measures for each individual group of patients with chronic diseases seem obligatory. Regarding our recent experience with a patient suffering from PD, on DBS treatment, who needed hospitalization, we felt useful to share our experience as a recommended protocol for similar patients in the time of current pandemic. Conclusion: Close monitoring of laboratory and clinical signs should be warranted in patients with PD awaiting IPG replacement in order to be prepared in these novel conditions that may precipitate an akinetic crisis/dystonic storm and to prevent life-threatening complications during the current pandemic.

2010 ◽  
Vol 2010 ◽  
pp. 1-4 ◽  
Author(s):  
Ankur Garg ◽  
Avinash L. Mohan ◽  
P. Charles Garell

Deep brain stimulation (DBS) is a common surgical procedure used for the treatment of Parkinson's disease (PD) and essential tremor. A potential complication of this procedure is hardware failure. The authors report a case of DBS hardware failure in which repeated fractures of the extension wire were caused by abnormal rotational movements of the IPG placed in the loose subclavicular tissue of an overweight female. Implantation of the IPG in the suprascapular area prevented further extension wire fractures. This strategy may be especially relevant in overweight females with loose subclavicular tissue.


2010 ◽  
Vol 113 (3) ◽  
pp. 630-633 ◽  
Author(s):  
Jonathan A. Hyam ◽  
Nicholas de Pennington ◽  
Carole Joint ◽  
Alexander L. Green ◽  
Sarah L. F. Owen ◽  
...  

Infection in the context of implant surgery is a dreaded complication, usually necessitating the removal of all affected hardware. Severe dystonia is a debilitating condition that can present as an emergency and can occasionally be life threatening. The authors present 2 cases of severe dystonia in which deep brain stimulation was maintained despite the presence of infection, using ongoing stimulation by externalization of electrode wires and an extracorporeal pulse generator. This allowed the infection to clear and wounds to heal while maintaining stimulation. This strategy is similar to that used in the management of infected cardiac pacemakers. The authors suggest that this prolonged extracorporeal stimulation should be considered by neurosurgeons in the face of this difficult clinical situation.


2020 ◽  
Vol 133 (2) ◽  
pp. 403-410 ◽  
Author(s):  
Travis J. Atchley ◽  
Nicholas M. B. Laskay ◽  
Brandon A. Sherrod ◽  
A. K. M. Fazlur Rahman ◽  
Harrison C. Walker ◽  
...  

OBJECTIVEInfection and erosion following implantable pulse generator (IPG) placement are associated with morbidity and cost for patients with deep brain stimulation (DBS) systems. Here, the authors provide a detailed characterization of infection and erosion events in a large cohort that underwent DBS surgery for movement disorders.METHODSThe authors retrospectively reviewed consecutive IPG placements and replacements in patients who had undergone DBS surgery for movement disorders at the University of Alabama at Birmingham between 2013 and 2016. IPG procedures occurring before 2013 in these patients were also captured. Descriptive statistics, survival analyses, and logistic regression were performed using generalized linear mixed effects models to examine risk factors for the primary outcomes of interest: infection within 1 year or erosion within 2 years of IPG placement.RESULTSIn the study period, 384 patients underwent a total of 995 IPG procedures (46.4% were initial placements) and had a median follow-up of 2.9 years. Reoperation for infection occurred after 27 procedures (2.7%) in 21 patients (5.5%). No difference in the infection rate was observed for initial placement versus replacement (p = 0.838). Reoperation for erosion occurred after 16 procedures (1.6%) in 15 patients (3.9%). Median time to reoperation for infection and erosion was 51 days (IQR 24–129 days) and 149 days (IQR 112–285 days), respectively. Four patients with infection (19.0%) developed a second infection requiring a same-side reoperation, two of whom developed a third infection. Intraoperative vancomycin powder was used in 158 cases (15.9%) and did not decrease the infection risk (infected: 3.2% with vancomycin vs 2.6% without, p = 0.922, log-rank test). On logistic regression, a previous infection increased the risk for infection (OR 35.0, 95% CI 7.9–156.2, p < 0.0001) and a lower patient BMI was a risk factor for erosion (BMI ≤ 24 kg/m2: OR 3.1, 95% CI 1.1–8.6, p = 0.03).CONCLUSIONSIPG-related infection and erosion following DBS surgery are uncommon but clinically significant events. Their respective timelines and risk factors suggest different etiologies and thus different potential corrective procedures.


2013 ◽  
Vol 124 (3) ◽  
pp. 166-174 ◽  
Author(s):  
Jules M. Nazzaro ◽  
Joshua A. Klemp ◽  
William M. Brooks ◽  
Galen Cook-Wiens ◽  
Matthew S. Mayo ◽  
...  

2014 ◽  
Vol 2014 ◽  
pp. 1-9 ◽  
Author(s):  
Sara Manafi ◽  
Hai Deng

A small planar modified Minkowski fractal antenna is designed and simulated in dual frequency bands (2.4 and 5.8 GHz) for wireless energy harvesting by deep brain stimulation (DBS) devices. The designed antenna, physically being confined inside a miniaturized structure, can efficiently convert the wireless signals in dual ISM frequency bands to the energy source to recharge the DBS battery or power the pulse generator directly. The performance metrics such as the return loss, the specific absorption rate (SAR), and the radiation pattern within skin and muscle-fat-skin tissues are evaluated for the designed antenna. The gain of the proposed antenna is 3.2 dBi at 2.4 GHz and 4.7 dBi at 5.8 GHz; also the averaged SAR of the antenna in human body tissue is found to be well below the legally allowed limit at both frequency bands. The link budget shows the received power at the distance of 25 cm at 2.4 GHz and 5.8 GHz are around 0.4 mW and 0.04 mW, which can empower the DBS implant. The large operational bandwidth, the physical compactness, and the efficiency in wireless signal reception make this antenna suitable in being used in implanted biomedical devices such as DBS pulse generators.


2017 ◽  
Vol 126 (1) ◽  
pp. 108-113 ◽  
Author(s):  
Alastair J. Martin ◽  
Paul S. Larson ◽  
Nathan Ziman ◽  
Nadja Levesque ◽  
Monica Volz ◽  
...  

OBJECTIVE The objective of this study was to assess the incidence of postoperative hardware infection following interventional (i)MRI–guided implantation of deep brain stimulation (DBS) electrodes in a diagnostic MRI scanner. METHODS A diagnostic 1.5-T MRI scanner was used over a 10-year period to implant DBS electrodes for movement disorders. The MRI suite did not meet operating room standards with respect to airflow and air filtration but was prepared and used with conventional sterile procedures by an experienced surgical team. Deep brain stimulation leads were implanted while the patient was in the magnet, and patients returned 1–3 weeks later to undergo placement of the implantable pulse generator (IPG) and extender wire in a conventional operating room. Surgical site infections requiring the removal of part or all of the DBS system within 6 months of implantation were scored as postoperative hardware infections in a prospective database. RESULTS During the 10-year study period, the authors performed 164 iMRI-guided surgical procedures in which 272 electrodes were implanted. Patients ranged in age from 7 to 78 years, and an overall infection rate of 3.6% was found. Bacterial cultures indicated Staphylococcus epidermis (3 cases), methicillin-susceptible Staphylococcus aureus (2 cases), or Propionibacterium sp. (1 case). A change in sterile practice occurred after the first 10 patients, leading to a reduction in the infection rate to 2.6% (4 cases in 154 procedures) over the remainder of the procedures. Of the 4 infections in this patient subset, all occurred at the IPG site. CONCLUSIONS Interventional MRI–guided DBS implantation can be performed in a diagnostic MRI suite with an infection risk comparable to that reported for traditional surgical placement techniques provided that sterile procedures, similar to those used in a regular operating room, are practiced.


2012 ◽  
Vol 9 (1) ◽  
pp. 99-102 ◽  
Author(s):  
Brian P. Walcott ◽  
Brian V. Nahed ◽  
Kristopher T. Kahle ◽  
Ann-Christine Duhaime ◽  
Nutan Sharma ◽  
...  

Generalized dystonic syndromes may escalate into persistent episodes of generalized dystonia known as status dystonicus that can be life-threatening due to dystonia-induced rhabdomyolysis and/or respiratory compromise. Treatment of these conditions usually entails parenteral infusion of antispasmodic agents and sedatives and occasionally necessitates a medically induced coma for symptom control. The authors report a series of 3 children who presented with medically intractable, life-threatening status dystonicus and were successfully treated with bilateral pallidal deep brain stimulation. Bilateral globus pallidus internus stimulation appears to be effective in the urgent treatment of medically refractory and life-threatening movement disorders.


2010 ◽  
Vol 88 (6) ◽  
pp. 353-359 ◽  
Author(s):  
Adam P. Burdick ◽  
Michael S. Okun ◽  
Ihtsham U. Haq ◽  
Herbert E. Ward ◽  
Frank Bova ◽  
...  

2017 ◽  
Vol 160 (2) ◽  
pp. 385-387
Author(s):  
Judith Anthofer ◽  
Andreas Herbst ◽  
Annettte Janzen ◽  
Max Lange ◽  
Alexander Brawanski ◽  
...  

2021 ◽  
Vol 15 ◽  
Author(s):  
Hongyang Li ◽  
Daoqing Su ◽  
Yijie Lai ◽  
Xinmeng Xu ◽  
Chencheng Zhang ◽  
...  

Background: Deep brain stimulation (DBS) is a well-established treatment for a variety of movement disorders. Rechargeable cell technology was introduced to pulse generator more than 10 years ago and brought great benefits to patients. However, with the widespread use of rechargeable implanted pulse generators (r-IPGs), a new hardware complication, when charging the r-IPG has been difficult, was encountered.Objective: The aims of this study were to report five cases confronted with r-IPG charging difficulty postoperatively and to explore the predisposing factors and treatment strategies for this rare complication.Methods: We retrospectively reviewed our DBS patient database for those who were implanted with r-IPGs. From 2012, we identified a total of 1,226 patients, with five of them experiencing charging difficulties after surgery. Detailed patient profiles and clinical procedures were scrutinized and reviewed.Results: All the charging problems were resolved by reoperation. Cases 1 and 2 required their r-IPGs to be anchored to the muscle and fascia. Cases 3 and 4 had their r-IPGs inserted in the wrong orientation at the initial surgery, which was resolved by turning around the r-IPGs at the revision surgery. Case 5, in which we propose that the thick subcutaneous fat layer blocked the connection between the r-IPG and the recharger, required a second operation to reposition the r-IPG in a shallow layer underneath the skin. For all cases, the charging problems were resolved without reoccurrences to date.Conclusion: Our case series indicates a novel hardware complication of DBS surgery, which had been rarely reported before. In this preliminary study, we describe several underlying causes of this complication and treatment methods.


Sign in / Sign up

Export Citation Format

Share Document