scholarly journals Pengaruh Parameter Milliampere-Second (mAs) terhadap Kualitas Citra Dan Dosis Radiasi Pada Pemeriksaan CT scan Kepala Pediatrik

2020 ◽  
Vol 17 (1) ◽  
pp. 1 ◽  
Author(s):  
Muhammad Irsal ◽  
Guntur Winarno

Radiographers are responsible for administering radiation doses according to the principle of As Low As Reasonably Achievable (ALARA), to optimize the use of CT parameters to produce good image quality by minimizing radiation doses. The purpose of this study was to determine the effect of mAs parameters on image quality and radiation dose received by pediatric CT head examination patients. The research method to perform image processing results of examination using radiant viewer and analysis of value Contrast to noise ratio (CNR) as a parameter of image quality and CTDIvol to determine the estimated radiation dose, then an analysis is performed to determine whether there is an influence of mAs on the CNR and CTDIvol values. The mean value of kV 116 ± 8.28, the mean value of parameter mAs 161.5 ± 63.46, the mean SNR parameter value is 7.5 ± 0.8, the mean return value of CNR parameter was 0.318 ± 0.291, the mean value of the CTDIvol parameter is 18.68 mGy ± 4.55 mGy, the average value of DLP parameters was 408.7 mGy x cm ± 105.2 mGy x cm, the mean value of parameter DLP is 441.2 mGy x cm ± 155.2 mGy x cm. With linear regression analysis of test results between mAs to CNR is R2 = 0.045. then to the results of linear regression between mAs against CTDI is R2 = 0704, the estimated radiation dose limit for the average value of CTDIvol 18.68 mGy and the average value of DLP 408.7 mGy x cm, this means the protocol CT scan of the head of the pediatric use is still within safe limits by Diagnostic Reference Level of BAPETEN in 2018 to pediatric head CT examination

2019 ◽  
Vol 188 (1) ◽  
pp. 73-78
Author(s):  
Anne Mattila ◽  
Heli Larjava ◽  
Olli Helminen ◽  
Matti Kairaluoma

Abstract This study aimed to determine the exposure to radiation delivered to the patient during routine intraoperative cholangiography (IOC) in cholecystectomy and examine the factors affecting radiation dose and fluoroscopy time (FT). From January 2016 to December 2017, 598 IOC examinations were performed. This study included 324 intraoperative cholangiographies performed with c-arm equipment not exceeding 10 years of age. When residents performed the procedures, the mean kerma area product (KAP) was 0.36 (standard deviation [SD] 0.70) Gycm 2 and in specialist surgeons group 0.36 (SD 0.47) Gycm2, P = 0.47. In residents group, the mean FT was 11.4 (SD 10.1) seconds and in specialist surgeons group, 9.2 (SD 11.9) seconds, P < 0.01. Linear regression analysis showed association between increased KAP-values and the presence of common bile duct (CBD) stones and body mass index (BMI). Age, BMI, laparoscopic surgery, acute cholecystitis, presence of CBD stones, resident surgeon performing IOC and ASA III–IV were associated with higher FT. National diagnostic reference level for IOC has not been introduced in Finland so far. Our mean KAP values (0.36 Gycm2) were 3–4 times lower and FT (10.1 seconds) were 3–5 times lower than the few reported in the literature. Routine use of IOC during cholecystectomy results in relatively low-radiation dose performed either by residents or specialist surgeons, irrespective of whether CBD stones were visualized or not.


Author(s):  
Nikos Rikos ◽  
Demetra Telli ◽  
Athanasia Hatzinikolaou ◽  
Demetra Mantikou ◽  
Michael Rovithis ◽  
...  

Background & Aim: The current study aimed to investigate workplace bullying, specifically verbal abuse of working nurses, and its consequences on the physical and psychological levels. Methods & Materials: A cross-sectional study was designed and implemented in 151 nurses working at a university hospital. The survey was conducted in 2018 at a university hospital in Greece, and the Verbal Abuse Scale (G-AVQ v.0/2015) was used to assess the verbal abuse level. Multiple linear regression analysis was applied, and distributions were tested for their symmetry using Blom's method (QQ plot). Results: 88.1% were women as the mean age of all was 41.7 years and 16.1 years the mean length of employment. Almost all nurses (94.7%) reported experiencing verbal abuse, as 77.6% reported that the perpetrator was a patient's relative (p<0.05). Among cognitive assessment, coping, severity of effects, and strength of feeling, coping had the highest mean value the highest mean value, while severity of effects had the lowest (2.52 vs. 1.83, p<0.05). Multiple linear regression analysis showed that frequency of verbal abuse type has a significant correlation with higher coping (β=0.28, p=0.007) and strength of feeling values (β=0.29, p=0.010). Similarly, the severity of verbal abuse type has a significant correlation with higher strength of feeling values (β=0.30, p=0.014). Conclusion: Almost all the nurses reported experiencing verbal abuse as the 'patients' relatives were the main perpetrators. Although the nurses seem to cope with verbal abuse successfully, this fact is described as stressful. Moreover, the frequency, severity of verbal abuse, and consequences are correlated to the emotions that arise from it.


Dose-Response ◽  
2021 ◽  
Vol 19 (1) ◽  
pp. 155932582098566
Author(s):  
Bian Bingyang ◽  
Wang Gang ◽  
Shao Zhiqing ◽  
Nan Li ◽  
BoXu Zhou ◽  
...  

Objectives: In the present study, we introduced a practical approach to quantify organ-specific radiation doses and investigated whether low-dose head circumference (HC)-based protocols for non-enhanced head computed tomography (CT) could reduce organs-specific radiation dose in pediatric patients while maintaining high image quality. Methods: A total of 83 pediatric patients were prospectively recruited. Without limits to the HC, 15 patients were selected as a convention group (CON group) and underwent non-enhanced head CT scan with standard-dose protocols (tube current-time products of 250mAs). Low-dose group (LD group), including remaining 68 pediatrics were divided into 3 subgroups based on the HC: 54.1-57.0 cm for LD200mAs group (HC-based protocols of 200mAs), 51.1-54.0 cm for LD150mAs group (HC-based protocols of 150mAs), 48.1-51.0 cm for LD100mAs group (HC-based protocols of 100mAs). Subjective and objective image quality was evaluated and measured by 2 experienced radiologists. Radimetrics was used to calculate organs-specific radiation dose, including the brain, eye lenses, and salivary glands. Results: In CON250mAs group, radiation doses in the brain and salivary glands were conversely correlated with HC, and pediatric patients with smaller HC received higher organs-specific radiation dose. Reducing tube current-time product from 250 to 100mAs could significantly reduce the organ-specific radiation dose. The subjective image quality score ≥ 3.0 is acceptable for diagnosis purposes. The signal to noise ratio (SNR) and the contrast to noise ratio (CNR) of bilateral thalamus and centrum semiovale in 3 LD subgroups were not statistically different compared with the CON group. Conclusion: Our research indicated that low-dose HC-based protocols of non-enhanced head CT scan can evidently reduce the organ-specific radiation doses, while maintaining high image quality. HC can serve as a vital tool to guide personalized low-dose head CT scan for pediatric patients.


1988 ◽  
Vol 29 (4) ◽  
pp. 481-485 ◽  
Author(s):  
R. Havukainen

The radiation dose exposure, and the faults in about 1700 dental units inspected at dental surgeries by the Finnish Centre for Radiation and Nuclear Safety in 1981–1985, were analysed. The mean value of skin doses in the bite-wing projection was about 6.2 mGy, the range 0.5 to 151 mGy. The mean energy imparted per bite-wing examination was estimated as 0.68 mJ and that per panoramic examination as 1.2 mJ. That gives a total imparted energy of about 600 J per year for conventional dental examinations and about 420 J per year for panoramic examinations. This gives a total of 0.13 mJ from conventional and 0.089 mJ from panoramic examinations per inhabitant per year. The collective effective dose equivalent was calculated as about 9 manSv for conventional dental examinations and about 6 manSv for panoramic examinations. Twenty per cent of units had some fault which was capable of decreasing radiation safety. Forty per cent of units were served reparation orders or other remarks were made in inspection documents. Large doses were usually accounted for by incorrect film processing and malfunction of the exposure timer.


2020 ◽  
Vol 6 (1) ◽  
pp. 56-63
Author(s):  
Pooja Shah

Keywords: Effective dose, Dose Length Product, Computed Tomography Dose Indexvolume, Dose Reference Level AbstractAim: The aim of this study was to estimate the effective doses from CT scans using DoseLength Product (DLP) in a Nepalese hospital.Materials and methods: This prospective study was conducted in 150 patients above 18years of age who were referred for CT scan of head, chest and abdomen. The CT scan wasperformed on a 128 slice multi detector scanner. All the subjects who met the inclusioncriteria were included in the study. Following the non-contrast imaging phases of the head,chest and abdomen CTDIvol, DLP, kVp and pitch were recorded for each patient from theconsole display of the scanner. The effective dose was calculated for each examination usingDLP which were graphically analyzed and correlated with the age of the patient.Results: The study showed the mean CTDIvol for head, chest and abdomen to be 53.95±4.83mGy, 5.28±1.17 mGy and 11.15±2.71 mGy respectively along with mean DLP to be923.52±71.11 mGycm, 229.32±48.70 mGycm and 517.02±148.32 mGycm respectively. Usingthese values, the mean effective doses were calculated and found to be 1.93±0.14 mSv,3.20±0.68 mSv and 7.75±2.19 mSv respectively.Conclusion: The calculated effective dose values were lower than in other studies for CTexaminations of chest and abdomen while higher or similar for CT examination of head. Theresults of this survey could motivate other researchers to investigate the radiation doses inother hospitals and help establish national diagnostic reference levels.  


2020 ◽  
Vol 21 ◽  
Author(s):  
Caroline de Avila Fernandes ◽  
Fabiano Nunes Vaz ◽  
Leonir Luiz Pascoal ◽  
Paulo Santana Pacheco ◽  
Matheus Lehnhart de Moraes ◽  
...  

Abstract The aim of this study was to analyse precocity behaviour over nine years in Hereford steers and their crosses, slaughtered with from zero to six teeth. Approximately 144,000 certified carcases in the Carne Pampa programme were analysed between 2010 and 2018. The increase in cold carcase weight per year was evaluated for three periods of the year: the hot season was defined as 26 December to 25 May, the autumn void was defined as 26 May to 25 July, and the cold season from 26 July to 25 December. To assess the behaviour of cold carcase weight over the years per season, the data were submitted to simple linear regression analysis. The average weights per season were compared by the mean value comparison test. The cold season had the highest mean carcase weight, with 239.1 kg, showing an annual increase of 6.45 kg. Analysing the behaviour of mean carcase weight by dentition, animals with zero teeth showed a greater weight increase over the years during the cold season as well as during the autumn void; during the hot season, animals slaughtered with two teeth showed the greater increase in weight. The category that showed the least increase in weight for all three seasons were animals slaughtered with six teeth. It was concluded that over the nine years, there was an increase in slaughter precocity in male cattle certified in the Carne Pampa programme.


2021 ◽  
Vol 28 (Supplement_1) ◽  
Author(s):  
M Chlabicz ◽  
M Paniczko ◽  
J Jamolkowski ◽  
P Sowa ◽  
M Lapinska ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Public Institution(s). Main funding source(s): Medical University of Bialystok, Poland Introduction A low thigh circumference is associated with an increased risk of high blood pressure, diabetes, cardiovascular diseases, and total mortality. Objectives The aim of the study was to investigate the relationship between the thigh circumference and cardiovascular (CV) risk classes, and to assess what type of tissue, adipose tissue or muscle tissue affects the thigh circumference. Methods The longitudinal, population-based, Polish study was conducted in 2017-2020. A total of 931 individuals aged 20-79 were analyzed. Pol-SCORE system was used to assess the 10-year risk of fatal CV based on the following risk factors: age, gender, smoking, systolic blood pressure, and total cholesterol for individuals aged 40-70.  Then, CV risk classes were assessed using the 2019 ESC/EAS guidelines. The measurement of thigh circumference were performed directly below the gluteal fold of the thigh. Both thighs were measured and the mean value was calculated as the final thigh circumference. Body composition was assessed using Dual Energy X-ray Absorptiometry (DEXA). Results The mean age was 49.1 ± 15.5 years and 43.2% male. The mean thigh circumference was 58.2 ± 5.9 cm, the mean legs fat mass was 7.7 ± 2.8kg, and the mean legs lean mass was 16.9 ± 4.0kg. Lower thigh circumference was associated with higher CV risk classes in univariate linear regression analysis (β -0.516, p = 0.002), as well adjusted by age and sex (β -0.839, p = 0.008), adjusted by age, sex, BMI (β -0.886, p &lt;0.001), and age, sex, WHR (β -0.988, p &lt;0.001). In linear regression analysis legs adipose tissue and muscle tissue were related to the thigh circumference independently of CV risk classes (Model 1) and Pol-SCORE value (Model 2). However, fatty tissue (Model 1: β 0.746, p &lt; 0.001; Model 2: β 0.749, p &lt; 0.001) affects the thigh circumference more than the muscle tissue (Model 1: β 0.479, p &lt; 0.001; Model 2: β 0.442, p &lt; 0.001) (Fig. 1). Conclusion Smaller thigh circumference was associated with higher CV risk classes. Thigh circumference was more influenced by adipose tissue than by muscle tissue, regardless of the Pol-SCORE  or CV risk classes. Table 1. Variable Model 1 Model 2 Beta p R2 Beta p R2 Legs fat mass 0.746 &lt;0.001 0.785 0.749 &lt;0.001 0.760 Legs lean mass 0.479 &lt;0.001 0.785 0.442 &lt;0.001 0.760 Model 1: adjusted for Cardiovascular risk classesModel 2: adjusted for Pol-SCOREResults of the linear regression analysis thigh circumference in the general population Abstract Figure 1.


2018 ◽  
Vol 2018 ◽  
pp. 1-10 ◽  
Author(s):  
Richard G. Kavanagh ◽  
John O’Grady ◽  
Brian W. Carey ◽  
Patrick D. McLaughlin ◽  
Siobhan B. O’Neill ◽  
...  

Magnetic resonance imaging (MRI) is the mainstay method for the radiological imaging of the small bowel in patients with inflammatory bowel disease without the use of ionizing radiation. There are circumstances where imaging using ionizing radiation is required, particularly in the acute setting. This usually takes the form of computed tomography (CT). There has been a significant increase in the utilization of computed tomography (CT) for patients with Crohn’s disease as patients are frequently diagnosed at a relatively young age and require repeated imaging. Between seven and eleven percent of patients with IBD are exposed to high cumulative effective radiation doses (CEDs) (>35–75 mSv), mostly patients with Crohn’s disease (Newnham E 2007, Levi Z 2009, Hou JK 2014, Estay C 2015). This is primarily due to the more widespread and repeated use of CT, which accounts for 77% of radiation dose exposure amongst patients with Crohn’s disease (Desmond et al., 2008). Reports of the projected cancer risks from the increasing CT use (Berrington et al., 2007) have led to increased patient awareness regarding the potential health risks from ionizing radiation (Coakley et al., 2011). Our responsibilities as physicians caring for these patients include education regarding radiation risk and, when an investigation that utilizes ionizing radiation is required, to keep radiation doses as low as reasonably achievable: the “ALARA” principle. Recent advances in CT technology have facilitated substantial radiation dose reductions in many clinical settings, and several studies have demonstrated significantly decreased radiation doses in Crohn’s disease patients while maintaining diagnostic image quality. However, there is a balance to be struck between reducing radiation exposure and maintaining satisfactory image quality; if radiation dose is reduced excessively, the resulting CT images can be of poor quality and may be nondiagnostic. In this paper, we summarize the available evidence related to imaging of Crohn’s disease, radiation exposure, and risk, and we report recent advances in low-dose CT technology that have particular relevance.


2016 ◽  
Vol 25 (4) ◽  
pp. 230-234
Author(s):  
Wai-Yung Yu ◽  
Thye Sin Ho ◽  
Henry Ko ◽  
Wai-Yee Chan ◽  
Serene Ong ◽  
...  

Introduction: The use of computed tomography (CT) imaging as a diagnostic modality is increasing rapidly and CT is the dominant contributor to diagnostic medical radiation exposure. The aim of this project was to reduce the effective radiation dose to patients undergoing cranial CT examination, while maintaining diagnostic image quality. Methods: Data from a total of 1003, 132 and 27 patients were examined for three protocols: CT head, CT angiography (CTA), and CT perfusion (CTP), respectively. Following installation of adaptive iterative dose reduction (AIDR) 3D software, tube current was lowered in consecutive cycles, in a stepwise manner and effective radiation doses measured at each step. Results: Baseline effective radiation doses for CT head, CTA and CTP were 1.80, 3.60 and 3.96 mSv, at currents of 300, 280 and 130–150 mA, respectively. Using AIDR 3D and final reduced currents of 160, 190 and 70–100 mA for CT head, CTA and CTP gave effective doses of 1.29, 3.18 and 2.76 mSv, respectively. Conclusion: We demonstrated that satisfactory reductions in the effective radiation dose for CT head (28.3%), CTA (11.6%) and CTP (30.1%) can be achieved without sacrificing diagnostic image quality. We have also shown that iterative reconstruction techniques such as AIDR 3D can be effectively used to help reduce effective radiation dose. The dose reductions were performed within a short period and can be easily achievable, even in busy departments.