scholarly journals Verification of the method of finding a faulty sensor in reduced meters

2021 ◽  
pp. 100-107
Author(s):  
E Gorelov ◽  
Oleksander Zbrutsky ◽  
S Schogoleva

The reliability of the method for determining a failed sensor in a redundant angular velocity meter (AVM) by means of its experimental verification is considered. The mutual non-orthogonal arrangement of six axes of sensor sensitivity has been optimized to reduce the instrumental errors of each sensitive element and ensure the equality of their contribution. Provides approximately the same sensitivity to the level of error in case of failure. One of the six experimentally obtained sensor signals contains an error that exceeds the specified permissible limit. The algorithm for searching for a sensor is checked, the error of which exceeds the specified one, and which, for this reason, is considered faulty.

2012 ◽  
Vol 542-543 ◽  
pp. 727-730
Author(s):  
Chuan Zhi Mei ◽  
Lin Hua Piao ◽  
Quan Gang Yu ◽  
Bao Li Zhang ◽  
Xia Ding ◽  
...  

This paper reports about a nozzle array structure fluidic gyroscope. The gyro used setting sub-nozzle around the main nozzle to inhibit the attenuation which had been caused by the main nozzle jet column spread out and to increase the angular velocity difference of sensitive element in the thermal resistance wire when the jet flow rate had been input, thereby to improve the performance of the jet gyro. The test results showed that: a resolution of better than 0.1°/s nozzle formation jet gyro sensitivity better than 10mv/(0.1°/s), the measurement range is better than ± 60°/s; non-linearity of better than 1%.The impact of the gyroscope impact resistance capability, small size and wide range of applications.


Akustika ◽  
2021 ◽  
pp. 168-172
Author(s):  
Nikolay Akhremenko ◽  
Yasemin Durukan ◽  
Ekaterina Popkova ◽  
Mikhail Shevelko

The paper discusses the principles of the occurrence of inherent noise of the sensitive element of the angular velocity sensor, the calculation of these noises and methods of their reduction. The principle of operation of the sensing element of the angular velocity sensor on bulk acoustic waves, which consists in detecting the rotation of the polarization vector of the emitted linearly polarized shear wave, is presented in the work. The results of calculations of the noise level for various materials and sizes of plate piezoelectric transducers and acoustic duct are presented in the work. It is shown that a sensitive element with plate piezoelectric transducers made of langasite and an acoustic duct made of glass, a heavy flint, has a minimum noise level. It is shown that with an increase in the operating frequency of a plate piezoelectric transducer, the noise level decreases. A program for calculating the noise characteristics of solid-state angular velocity sensors based on bulk acoustic waves has been developed. The element base of the receiving amplifier of the device has been selected. Recommendations for reducing the level of noise are formulated, such as: increasing the operating frequency and reducing the bandwidth of plate piezoelectric transducers, as well as the choice of optimal materials for both piezoelectric transducers and acoustic duсt.


2013 ◽  
Vol 753-755 ◽  
pp. 2700-2703
Author(s):  
Jing Bo Chen ◽  
Lin Hua Piao ◽  
Pan Pan Yang

In this paper, research the influence on spacing thermal wires in the sensitive element of fluidic gyroscope. Using ANSYS-FLOTRAN CFD software, the finite element simulation is conducted by a series of procedures, such as two-dimensional model building of fluidic gyroscope, meshing, loads applying and equation solving. The two-dimensional airflow distributions of different distances between two thermal wires in sensitive element of fluidic gyroscope are calculated. The results show that, when the angular velocity ωi<20o/s, and the distance between two thermal wires d=4mm, the structure can reduce the velocity of vortex in sensitive element, and increase the thermal wires variation, thus it will increase bridge output voltage, and improve the sensitivity of fluidic gyroscope.


1966 ◽  
Vol 25 ◽  
pp. 323-325 ◽  
Author(s):  
B. Garfinkel

The paper extends the known solution of the Main Problem to include the effects of the higher spherical harmonics of the geopotential. The von Zeipel method is used to calculate the secular variations of orderJmand the long-periodic variations of ordersJm/J2andnJm,λ/ω. HereJmandJm,λare the coefficients of the zonal and the tesseral harmonics respectively, withJm,0=Jm, andωis the angular velocity of the Earth's rotation. With the aid of the theory of spherical harmonics the results are expressed in a most compact form.


2020 ◽  
pp. 54-59
Author(s):  
A. A. Yelizarov ◽  
A. A. Skuridin ◽  
E. A. Zakirova

A computer model and the results of a numerical experiment for a sensitive element on a planar mushroom-shaped metamaterial with cells of the “Maltese cross” type are presented. The proposed electrodynamic structure is shown to be applicable for nondestructive testing of geometric and electrophysical parameters of technological media, as well as searching for inhomogeneities in them. Resonant frequency shift and change of the attenuation coefficient value of the structure serve as informative parameters.


2020 ◽  
Vol 2 (1) ◽  
Author(s):  
Rizki Andalia ◽  
Mulia Aria Suzanni ◽  
Rini Rini

Lipstick or lip dye is a cosmetic dose that serves to coloring, decorative the lips, as a moisturizing material and protect the lips from exposure the sun to provide optimum results. Lipstick should not contain chemicals such as lead (Pb) because the Pb is a heavy metal that is very dangerous when continuously used on the skin, because it will be absorbed into the blood and attack the body organ causing the onset of disease. According to BPOM that the lead rate on the lipstick does not exceed the permissible limit of 20 mg/kg or 20 ppm.This research aims to know the levels contained in the samples are 4 brands of matte lipstick that are sold in the Aceh market in Banda Aceh City with the method of atomic absorption spectrophotometry (AAS). The results showed that on the 4 brands of lipstick matte contain heavy metal lead (Pb) with a rate still qualified allowed by BPOM  is samples A, B, C, and D, respectively at 0.24 ppm; 0.10 ppm; 2.87 ppm and 1.32 ppm, so that the 4 brands of lipstick matte are still used.


Sign in / Sign up

Export Citation Format

Share Document