scholarly journals Exploring FPGA Based Lock-in Techniques for Brain Monitoring Applications

Author(s):  
Giuseppe Costantino Giaconia ◽  
Giuseppe Greco ◽  
Leonardo Mistretta ◽  
Raimondo Rizzo

Functional Near Infrared Spectroscopy (fNIRS) systems for e-health applications usually suffer of poor signal detection mainly due to a low end-to-end signal to noise ratio of the electronics chain. Lock-In Amplifiers (LIA) historically represent a powerful technique helping to improve performances in such circumstances. In this work it has been designed and implemented a digital LIA system, based on a Zynq® Field Programmable Gate Array (FPGA), trying to explore if this technique might improve fNIRS system performances. More broadly, FPGA based solution flexibility has been investigated, with particular emphasis applied to digital filter parameters, needed in the digital LIA, and it has been evaluated its impact on the final signal detection and noise rejection capability. The realized architecture was a mixed solution between VHDL hardware modules and software ones, running within a softcore microprocessor. Experimental results have shown the goodness of the proposed solutions and comparative details among different implementation will be detailed. Finally a key aspect taken into account throughout the design was its modularity, allowing an ease increase of the input channels while avoiding the growth of the design cost of the electronics system.

2013 ◽  
Vol 389 ◽  
pp. 489-493
Author(s):  
Yong Lv ◽  
Chun Hui Niu ◽  
Yue Qiang Li ◽  
Qing Shan Chen ◽  
Xiao Ying Li ◽  
...  

In order to detect the weak signal deeply buried in the noise, a weak signal detection system based on lock-in amplifier is proposed. The system includes the preamplifier circuit, active low pass filter circuit, AC amplifying circuit and phase sensitive demodulation circuit. Test results show that it can greatly increase the signal-to-noise ratio (SNR) up to 12.7db.


2021 ◽  
Author(s):  
Laura Jones ◽  
Madeleine Verriotis ◽  
Robert Cooper ◽  
Maria Laudiano-Dray ◽  
Mohammed Rupawala ◽  
...  

Topographic cortical maps are essential for spatial localisation of sensory stimulation and generation of appropriate task-related motor responses. Somatosensation and nociception are finely mapped and aligned in the adult somatosensory (S1) cortex, but in infancy, when pain behaviour is disorganised and poorly directed, nociceptive maps may be less refined. We compared the topographic pattern of S1 activation following noxious (clinically required heel lance) and innocuous (touch) mechanical stimulation of the same skin region in newborn infants (n=32) using multi-optode functional near-infrared spectroscopy (fNIRS). Signal to noise ratio and overall activation area did not differ with stimulus modality. Within S1 cortex, touch and lance of the heel elicit localised, partially overlapping increases in oxygenated haemoglobin (HbO), but while touch activation was restricted to the heel area, lance activation extended into cortical hand regions. The data reveals a widespread cortical nociceptive map in infant S1, consistent with their poorly directed pain behaviour.


2013 ◽  
Vol 06 (04) ◽  
pp. 1350035
Author(s):  
MEHDI AMIAN ◽  
S. KAMALEDIN SETAREHDAN

Functional near infrared spectroscopy (fNIRS) is a technique that is used for noninvasive measurement of the oxyhemoglobin (HbO2) and deoxyhemoglobin (HHb) concentrations in the brain tissue. Since the ratio of the concentration of these two agents is correlated with the neuronal activity, fNIRS can be used for the monitoring and quantifying the cortical activity. The portability of fNIRS makes it a good candidate for studies involving subject's movement. The fNIRS measurements, however, are sensitive to artifacts generated by subject's head motion. This makes fNIRS signals less effective in such applications. In this paper, the autoregressive moving average (ARMA) modeling of the fNIRS signal is proposed for state-space representation of the signal which is then fed to the Kalman filter for estimating the motionless signal from motion corrupted signal. Results are compared to the autoregressive model (AR) based approach, which has been done previously, and show that the ARMA models outperform AR models. We attribute it to the richer structure, containing more terms indeed, of ARMA than AR. We show that the signal to noise ratio (SNR) is about 2 dB higher for ARMA based method.


Sensors ◽  
2021 ◽  
Vol 21 (15) ◽  
pp. 5117
Author(s):  
David Perpetuini ◽  
Daniela Cardone ◽  
Chiara Filippini ◽  
Antonio Maria Chiarelli ◽  
Arcangelo Merla

Functional near infrared spectroscopy (fNIRS) is a neuroimaging technique that allows to monitor the functional hemoglobin oscillations related to cortical activity. One of the main issues related to fNIRS applications is the motion artefact removal, since a corrupted physiological signal is not correctly indicative of the underlying biological process. A novel procedure for motion artifact correction for fNIRS signals based on wavelet transform and video tracking developed for infrared thermography (IRT) is presented. In detail, fNIRS and IRT were concurrently recorded and the optodes’ movement was estimated employing a video tracking procedure developed for IRT recordings. The wavelet transform of the fNIRS signal and of the optodes’ movement, together with their wavelet coherence, were computed. Then, the inverse wavelet transform was evaluated for the fNIRS signal excluding the frequency content corresponding to the optdes’ movement and to the coherence in the epochs where they were higher with respect to an established threshold. The method was tested using simulated functional hemodynamic responses added to real resting-state fNIRS recordings corrupted by movement artifacts. The results demonstrated the effectiveness of the procedure in eliminating noise, producing results with higher signal to noise ratio with respect to another validated method.


2019 ◽  
Author(s):  
Hüsser Alejandra ◽  
Caron-Desrochers Laura ◽  
Tremblay Julie ◽  
Vannasing Phetsamone ◽  
Martínez-Montes Eduardo ◽  
...  

AbstractSignificanceFunctional near-infrared spectroscopy (fNIRS) is a neuroimaging technique that uses near-infrared lights to estimate cerebral hemodynamic response, based on concentration changes in oxygenated and deoxygenated hemoglobin. A multi-dimensional decomposition technique, parallel factor (PARAFAC) analysis, has been validated for the identification of artifacts and cerebral activation patterns in electroencephalography and neuroimaging.AimWe aimed at introducing and validating the use of the PARAFAC model for fNIRS data analysis, which is inherently multidimensional (time, space, wavelength).ApproachEighteen healthy adults underwent fNIRS acquisition during a verbal fluency task. The signal-to-noise ratio and Pearson’s correlation were used to evaluate the efficacy of PARAFAC for motion artifact correction. Temporal, spatial and hemodynamic characteristics of the PARAFAC component allowed to identify task-related cerebral activations.ResultsMotion artifact correction with PARAFAC led to significant improvements in data quality and other advantages as compared to traditional 2D approaches (ICA, tPCA). Although PARAFAC revealed a slightly more distributed functional network, temporal and spatial characteristics of the task-related brain activation identified with PARAFAC mostly overlapped with those obtained with commonly used approaches.ConclusionThis study describes the first implementation of PARAFAC in fNIRS and supports it as a promising data-driven alternative for multi-dimensional data analyses in fNIRS.


2021 ◽  
Vol 8 (3) ◽  
Author(s):  
Huiquan Wang ◽  
Meng Hu ◽  
Fang Xia ◽  
Meng Guo ◽  
Shengzhao Zhang ◽  
...  

In this paper, the signal-to-noise ratios (SNR) of two image channels were enhanced with the fast digital lock-in algorithm. In order to simultaneously improve the quality of white and fluorescence images obtained by fluorescence endoscope, and improve the SNR to achieve a better image processing effect, two sources of white light and near-infrared light of a fluorescence endoscope were modulated, then the acquired images were demodulated into white and fluorescence images. A fluorescent endoscope experimental platform was setup to acquire endoscopic images of a target dyed by indocyanine green. The experimental results showed that the SNR of white and fluorescent images without the lock-in algorithm were 36.56 dB and 33.47 dB, respectively. However, with the lock-in algorithm, the SNR of white and fluorescent images were 39.54 dB and 35.70 dB, respectively. The SNR of white and fluorescent images was increased by 8.2% and 6.7%, respectively, by appling the digital lock-in algorithm. Therefore, this novel fluorescence endoscope based on the fast digital lock-in algorithm can rapidly and simultaneously obtain two-channel images of white light and fluorescence, effectively enhance the SNR of white and fluorescent images, and improve the imaging quality.