scholarly journals Overhead power lines magnetic field reducing in multi-story building by active shielding means

Author(s):  
B. I. Kuznetsov ◽  
T. B. Nikitina ◽  
I. V. Bovdui ◽  
V. V. Kolomiets ◽  
B. B. Kobylianskiy

Aim. Reducing of magnetic flux density of magnetic field in multi-storey building, generated by overhead power lines to the sanitary standards level by active shielding means. The tasks of the work are the synthesis, computer simulation and experimental research of three-circuits system of active shielding, which includes three shielding coils. Methodology. When synthesizing the system of active shielding of magnetic field, are determined their number, configuration, spatial arrangement and of shielding coils as well as the shielding coils currents and resulting magnetic flux density value in the shielding space. The synthesis is based on the multi-criteria game decision, in which the payoff vector is calculated on the basis on quasi-stationary approximation solutions of the Maxwell equations. The game decision is based on the stochastic particles multiswarm optimization algorithms. Results. Computer simulation and experimental research of three-circuit system of active shielding of magnetic field, generated by overhead power lines with phase conductors triangle arrangements in multi-storey building are given. The possibility of initial magnetic flux density level reducing in multi-storey building to the sanitary standards level is shown. Originality. For the first time to reducing of magnetic flux density of magnetic field in multi-storey building the synthesis, computer simulation and experimental research of three-circuit system of active shielding of magnetic field generated by single-circuit overhead power line with phase conductors triangular arrangements carried out. Practical value. Practical recommendations from the point of view of the practical implementation on reasonable choice of the spatial arrangement of three shielding coils of three-circuit system of active shielding of the magnetic field generated by single-circuit overhead power line with phase conductors triangular arrangements in multi-storey building are given.

2019 ◽  
Vol 32 (4) ◽  
pp. 555-569
Author(s):  
Slavko Vujevic ◽  
Tonci Modric

There has been apprehension about the possible adverse health effects resulting from exposure to power frequency magnetic field, especially in the overhead power lines vicinity. Research work on the biological effects of magnetic field has been substantial in recent decades. Various international regulations and safety guidelines, aimed at the protection of human beings, have been issued. Numerous measurements are performed and different numerical algorithms for computation of the magnetic field, based on the Biot- Savart law, are developed. In this paper, a previously developed 3D quasistatic numerical algorithm for computation of the magnetic field (i.e. magnetic flux density) produced by overhead power lines has been improved in such a way that cylindrical segments of passive conductors are also taken into account. These segments of passive conductors form the conductive passive contours, which can be natural or equivalent, and they substitute conductive passive parts of the overhead power lines and towers. Although, their influence on the magnetic flux density distribution and on the total effective values of magnetic flux density is small, it is quantified in a numerical example, based on a theoretical background that was developed and presented in this paper.


Sensors ◽  
2021 ◽  
Vol 21 (7) ◽  
pp. 2522
Author(s):  
Guangdou Liu ◽  
Shiqin Hou ◽  
Xingping Xu ◽  
Wensheng Xiao

In the linear and planar motors, the 1D Halbach magnet array is extensively used. The sinusoidal property of the magnetic field deteriorates by analyzing the magnetic field at a small air gap. Therefore, a new 1D Halbach magnet array is proposed, in which the permanent magnet with a curved surface is applied. Based on the superposition of principle and Fourier series, the magnetic flux density distribution is derived. The optimized curved surface is obtained and fitted by a polynomial. The sinusoidal magnetic field is verified by comparing it with the magnetic flux density of the finite element model. Through the analysis of different dimensions of the permanent magnet array, the optimization result has good applicability. The force ripple can be significantly reduced by the new magnet array. The effect on the mass and air gap is investigated compared with a conventional magnet array with rectangular permanent magnets. In conclusion, the new magnet array design has the scalability to be extended to various sizes of motor and is especially suitable for small air gap applications.


2010 ◽  
Vol 129-131 ◽  
pp. 692-696
Author(s):  
Jian Bing Meng ◽  
Xiao Juan Dong ◽  
Chang Ning Ma

A mathematical model was developed to describe the oscillating amplitude of the plasma arc injected transverse to an external transverse alternating magnetic field. The characteristic of plasma arc under the external transverse alternating magnetic field imposed perpendicular to the plasma current was discussed. The effect of processing parameters, such as flow rate of working gas, arc current, magnetic flux density and the standoff from the nozzle to the workpiece, on the oscillation of plasma arc were also analyzed. The results show that it is feasible to adjust the shape of the plasma arc by the transverse alternating magnetic field, which expands the region of plasma arc thermal treatment upon the workpiece. Furthermore, the oscillating amplitude of plasma arc decreases with decrease of the magnetic flux density. Under the same magnetic flux density, more gas flow rate, more arc current, and less standoff cause the oscillating amplitude to decrease. The researches have provided a deeper understanding of adjusting of plasma arc characteristics.


2019 ◽  
Vol 9 (3) ◽  
pp. 22
Author(s):  
António Roque ◽  
Duarte M. Sousa ◽  
Pedro Sebastião ◽  
Elmano Margato ◽  
Gil Marques

This paper describes an innovative solution for the power supply of a fast field cycling (FFC) nuclear magnetic resonance (NMR) spectrometer considering its low power consumption, portability and low cost. In FFC cores, the magnetic flux density must be controlled in order to perform magnetic flux density cycles with short transients, while maintaining the magnetic flux density levels with high accuracy and homogeneity. Typical solutions in the FFC NMR literature use current control to get the required magnetic flux density cycles, which correspond to an indirect magnetic flux density control. The main feature of this new relaxometer is the direct control of the magnetic flux density instead of the magnet current, in contrast with other equipment available in the market. This feature is a great progress because it improves the performance. With this solution it is possible to compensate magnetic field disturbances and parasitic magnetic fields guaranteeing, among other possibilities, a field control below the earth magnetic field. Experimental results validating the developed solution and illustrating the real operation of this type of equipment are shown.


Author(s):  
Seok Woo Lee ◽  
Seung S. Lee

In this paper, PDMS membrane for a large displacement is fabricated by new fabrication process which can be integrated with electrical components on substrates fabricated by conventional microfabrication processes and the performance of the membrane using electromagnetism was evaluated. Rectangular PDMS membranes are designed as 2mm and 3mm in width, respectively and are actuated by Lorentz force induced by current paths spread on the membrane. The PDMS membrane is fabricated by reducing a viscosity of uncured PDMS with dilution and spin coating on the substrate on which electric components generating Lorentz force. Finally, PDMS membrane including electric components is opened by a bulk micromachining. The device is tested in magnetic field induced by Nd-Fe-B magnet whose magnetic flux density is 90G. When applied currents are 20, 25, and 30mA, the maximum deflections of membranes are 1.21, 3.07, and 20.2μm for 1.5mm width membrane and 3.34, 31.0, and 50.9μm for width 3mm membrane, respectively. The large displacement PDMS membrane actuator has potentially various applications such as fluidics, optics, acoustics, and electronics. Currently, we are planning to measure the optical performance of the actuator as a focal tunable liquid lens.


Author(s):  
Ping-Hsun Lee ◽  
Jen-Yuan (James) Chang

Abstract In this paper we proposed a platform for measuring shear force of magnetorheological (MR) fluid by which the relationship of yield stress and magnetic flux density of specific material can be determined. The device consisted of a rotatable center tube in a frame body and the magnetic field was provided by two blocks of permanent magnets placed oppositely outside the frame body. The magnitude and direction of the magnetic field were manipulated by changing the distance of the two permanent magnets from the frame body and rotating the center tube, respectively. For determining the magnetic field of the device, we adopted an effective method by fitting the FEM (finite element method) result to the measured one and then rebuilt the absent components to approximate the magnetic field, which was hardly to be measured simultaneously as different device setup were required. With the proposed platform and analytical methods, the drawing shear force and the corresponding yield stress contributed by MR fluid could be evaluated in respect to the magnitude and direction of given magnetic flux density with acceptable accuracy for specific designing purposes without a large, complex, and expensive instrument.


1999 ◽  
Vol 3 (2) ◽  
pp. 157-161 ◽  
Author(s):  
Yunbo Zhong ◽  
Zhongming Ren ◽  
Kang Deng ◽  
Guochang Jiang ◽  
Kuangdi Xu

2014 ◽  
Vol 565 ◽  
pp. 133-137
Author(s):  
Athirot Mano ◽  
Wisut Titiroongruang

In a measurement of magnetic flux density with high accuracy by using Hall effect sensor must be considered position of Hall sensor, that perfect perpendicular with magnetic flux line for measurement. Only one Hall element can cause measuring error. Therefore, this paper presents an application of independent directional magnetic field measurement technique on two dimensions for high accuracy magnetometer. It is presented by using two Hall sensors locate perpendicular to each other and use the relation of the two voltage output signal from both Hall sensors to calculate constant Hall voltage and Magnetic flux density with high accuracy by using trigonometric function with Lab-View programming. And as the result of experiment, this technique can reduce the limitation in term of this angle in the range magnetic flux density can be measured 0-1800 gauss. A calibration curve of this system compare with standard Gauss meter shows the coefficient of determination (R2) equal to 1 and has the accuracy percentage as less than 0.5%.


Author(s):  
Gui-Ping Zhu ◽  
Nam-Trung Nguyen

This paper reports the numerical and experimental investigation on magnetic particle concentration in a uniform magnetic field. The flow system consists of water-based ferrofluid and glycerol/DI water mixture streams. Two regimes were observed with spreading and mixing phenomena. With a low magnetic field strength, the spread of magnetic particles is caused by improved diffusion migration. With a relatively high field strength, instability at the interface would occur due to the mismatch in magnetization of the fluid streams. The transport of magnetic particles is induced by chaotic mixing of the fluids caused by a secondary flow. The mixing phenomena are characterized by magnetic flux density. For configuration with flow rate and viscosity ratio (between diamagnetic and magnetic streams) being set at 1 and 0.5, the mixing efficiency analyzed based on magnetic particles concentration increases approximately by 0.3 at around 3.5 mT. This value of magnetic flux density indicates the requirement on instability inception. The mixing efficiency increases with magnetic flux density increases further. Complete mixing can be achieved with a magnetic flux density at around 10 mT. The magnetic approach offers a wireless, heat-free and pH-independent solution for a lab-on-a-chip system.


Sign in / Sign up

Export Citation Format

Share Document