scholarly journals Coherent interfaces with mixed hybridization govern direct transformation from graphite to diamond

Author(s):  
Zhisheng Zhao ◽  
Kun Luo ◽  
Bing Liu ◽  
Wentao Hu ◽  
Xiao Dong ◽  
...  

Abstract Understanding the direct transformation from graphite to diamond has been a long-standing challenge with great scientific and practical importance. Previously proposed transformation mechanisms1-3, based on traditional experimental observations that lacked atomistic resolution, cannot account for the complex nanostructures occurring at graphite-diamond interfaces during the transformation4,5. Here, we report the identification of coherent graphite-diamond interfaces constituted with four structural motifs in partially transformed graphite samples recovered from static compression, using high-angle annular dark-field scanning transmission electron microscope. These observations provide vital insight into possible pathways of the transformation. Theoretical calculations confirm that transformation through these coherent interfaces is energetically favored to those through other paths previously proposed1-3. The graphite-to-diamond transformation is governed by the formation of nanoscale coherent interfaces (diamond nucleation), which, under static compression, advance to consume the remaining graphite (diamond growth). These results also shed light on transformation mechanisms of other carbon materials and boron nitride under different synthetic conditions.

Author(s):  
L. Gandolfi ◽  
J. Reiffel

Calculations have been performed on the contrast obtainable, using the Scanning Transmission Electron Microscope, in the observation of thick specimens. Recent research indicates a revival of an earlier interest in the observation of thin specimens with the view of comparing the attainable contrast using both types of specimens.Potential for biological applications of scanning transmission electron microscopy has led to a proliferation of the literature concerning specimen preparation methods and the controversy over “to stain or not to stain” in combination with the use of the dark field operating mode and the same choice of technique using bright field mode of operation has not yet been resolved.


Author(s):  
M. G. R. Thomson

The variation of contrast and signal to noise ratio with change in detector solid angle in the high resolution scanning transmission electron microscope was discussed in an earlier paper. In that paper the conclusions were that the most favourable conditions for the imaging of isolated single heavy atoms were, using the notation in figure 1, either bright field phase contrast with β0⋍0.5 α0, or dark field with an annular detector subtending an angle between ao and effectively π/2.The microscope is represented simply by the model illustrated in figure 1, and the objective lens is characterised by its coefficient of spherical aberration Cs. All the results for the Scanning Transmission Electron Microscope (STEM) may with care be applied to the Conventional Electron Microscope (CEM). The object atom is represented as detailed in reference 2, except that ϕ(θ) is taken to be the constant ϕ(0) to simplify the integration. This is reasonable for θ ≤ 0.1 θ0, where 60 is the screening angle.


Author(s):  
Earl J. Kirkland ◽  
Robert J. Keyse

An ultra-high resolution pole piece with a coefficient of spherical aberration Cs=0.7mm. was previously designed for a Vacuum Generators HB-501A Scanning Transmission Electron Microscope (STEM). This lens was used to produce bright field (BF) and annular dark field (ADF) images of (111) silicon with a lattice spacing of 1.92 Å. In this microscope the specimen must be loaded into the lens through the top bore (or exit bore, electrons traveling from the bottom to the top). Thus the top bore must be rather large to accommodate the specimen holder. Unfortunately, a large bore is not ideal for producing low aberrations. The old lens was thus highly asymmetrical, with an upper bore of 8.0mm. Even with this large upper bore it has not been possible to produce a tilting stage, which hampers high resolution microscopy.


Author(s):  
R.D. Leapman ◽  
S.Q. Sun ◽  
S-L. Shi ◽  
R.A. Buchanan ◽  
S.B. Andrews

Recent advances in rapid-freezing and cryosectioning techniques coupled with use of the quantitative signals available in the scanning transmission electron microscope (STEM) can provide us with new methods for determining the water distributions of subcellular compartments. The water content is an important physiological quantity that reflects how fluid and electrolytes are regulated in the cell; it is also required to convert dry weight concentrations of ions obtained from x-ray microanalysis into the more relevant molar ionic concentrations. Here we compare the information about water concentrations from both elastic (annular dark-field) and inelastic (electron energy loss) scattering measurements.In order to utilize the elastic signal it is first necessary to increase contrast by removing the water from the cryosection. After dehydration the tissue can be digitally imaged under low-dose conditions, in the same way that STEM mass mapping of macromolecules is performed. The resulting pixel intensities are then converted into dry mass fractions by using an internal standard, e.g., the mean intensity of the whole image may be taken as representative of the bulk water content of the tissue.


2017 ◽  
Vol 7 ◽  
pp. 184798041770717 ◽  
Author(s):  
Anna D Dobrzańska-Danikiewicz ◽  
Weronika Wolany ◽  
Dariusz Łukowiec ◽  
Karolina Jurkiewicz ◽  
Paweł Niedziałkowski

The purpose of the article is to discuss the process of oxidation of carbon nanotubes subsequently subjected to the process of decoration with rhenium nanoparticles. The influence of functionalization in an oxidizing medium is presented and the results of investigations using Raman spectroscopy and infrared spectroscopy are discussed. Multiwalled carbon nanotubes rhenium-type nanocomposites with the weight percentage of 10%, 20% and 30% of rhenium are also presented in the article. The structural components of such nanocomposites are carbon nanotubes decorated with rhenium nanoparticles. Microscopic examinations under transmission electron microscope and scanning transmission electron microscope using the bright and dark field confirm that nanocomposites containing about 20% of rhenium have the most homogenous structure.


1999 ◽  
Vol 5 (S2) ◽  
pp. 670-671 ◽  
Author(s):  
O.L. Krivanek ◽  
N. Dellby ◽  
A.R. Lupini

Even though two generations of electron microscopists have come to accept that the resolution of their instruments is limited by spherical aberration, three different aberration correctors showing that the aberration can be overcome have recently been built [1-3]. One of these correctors was developed by us specifically for forming small electron probes in a dedicated scanning transmission electron microscope (STEM) [3, 4]. It promises to revolutionize the way STEM instruments are built and the types of problems that they are applied to.As was the case with the Berlin Wall, when a barrier that was once thought immovable finally crumbles, many of the consequences can be quite unexpected. For STEM, the removal of spherical aberration (Cs) as the main resolution limit is likely to lead to a new paradigm in which:1) The resolution at a given operating voltage will improve by about 3x relative to today's best. When Cs can be adjusted arbitrarily in a STEM being used for microanalysis or dark field imaging, defocus and Cs are set to values that optimally oppose the effect of the 5th-order spherical aberration C5.


1999 ◽  
Vol 589 ◽  
Author(s):  
Y Kotaka ◽  
T. Yamazaki ◽  
Y Kikuchi ◽  
K. Watanabe

AbstractThe high-angle annular dark-field (HAADF) technique in a dedicated scanning transmission electron microscope (STEM) provides strong compositional sensitivity dependent on atomic number (Z-contrast image). Furthermore, a high spatial resolution image is comparable to that of conventional coherent imaging (HRTEM). However, it is difficult to obtain a clear atomic structure HAADF image using a hybrid TEM/STEM. In this work, HAADF images were obtained with a JEOL JEM-2010F (with a thermal-Schottky field-emission) gun in probe-forming mode at 200 kV. We performed experiments using Si and GaAs in the [110] orientation. The electron-optical conditions were optimized. As a result, the dumbbell structure was observed in an image of [110] Si. Intensity profiles for GaAs along [001] showed differences for the two atomic sites. The experimental images were analyzed and compared with the calculated atomic positions and intensities obtained from Bethe's eigen-value method, which was modified to simulate HAADF-STEM based on Allen and Rossouw's method for convergent-beam electron diffraction (CBED). The experimental results showed a good agreement with the simulation results.


Sign in / Sign up

Export Citation Format

Share Document