scholarly journals Comparison of Quantitative POCT Plasma D Dimer Values with Semiautomated Method (Research Article)

2021 ◽  
Vol 11 (1) ◽  
pp. 105-109
Author(s):  
R.D. Malathi ◽  
Jyotsna Volturi ◽  
Dawood Suleman
2008 ◽  
Vol 41 (10) ◽  
pp. 12-13
Author(s):  
JANE SALODOF MACNEIL
Keyword(s):  

2008 ◽  
Vol 1 (2) ◽  
pp. 11
Author(s):  
DAMIAN MCNAMARA
Keyword(s):  
D Dimer ◽  

VASA ◽  
2014 ◽  
Vol 43 (6) ◽  
pp. 450-458 ◽  
Author(s):  
Julio Flores ◽  
Ángel García-Avello ◽  
Esther Alonso ◽  
Antonio Ruíz ◽  
Olga Navarrete ◽  
...  

Background: We evaluated the diagnostic efficacy of tissue plasminogen activator (tPA), using an enzyme-linked immunosorbent assay (ELISA) and compared it with an ELISA D-dimer (VIDAS D-dimer) in acute pulmonary embolism (PE). Patients and methods: We studied 127 consecutive outpatients with clinically suspected PE. The diagnosis of PE was based on a clinical probability pretest for PE and a strict protocol of imaging studies. A plasma sample to measure the levels of tPA and D-dimer was obtained at enrollment. Diagnostic accuracy for tPA and D-dimer was determined by the area under the receiver operating characteristic (ROC) curve. Sensitivity, specificity, predictive values, and the diagnostic utility of tPA with a cutoff of 8.5 ng/mL and D-dimer with a cutoff of 500 ng/mL, were calculated for PE diagnosis. Results: PE was confirmed in 41 patients (32 %). Areas under ROC curves were 0.86 for D-dimer and 0.71 for tPA. The sensitivity/negative predictive value for D-dimer using a cutoff of 500 ng/mL, and tPA using a cutoff of 8.5 ng/mL, were 95 % (95 % CI, 88–100 %)/95 % (95 % CI, 88–100 %) and 95 % (95 % CI, 88–100 %)/94 %), respectively. The diagnostic utility to exclude PE was 28.3 % (95 % CI, 21–37 %) for D-dimer and 24.4 % (95 % CI, 17–33 %) for tPA. Conclusions: The tPA with a cutoff of 8.5 ng/mL has a high sensitivity and negative predictive value for exclusion of PE, similar to those observed for the VIDAS D-dimer with a cutoff of 500 ng/mL, although the diagnostic utility was slightly higher for the D-dimer.


1999 ◽  
Vol 82 (11) ◽  
pp. 1412-1416 ◽  
Author(s):  
Wojciech Zareba ◽  
John Horan ◽  
Arthur Moss ◽  
Joel Kanouse ◽  
◽  
...  

SummaryOur previous prospective study of post-infarction patients described a strong and significant association of increased plasma D-dimer concentrations in those who experienced a subsequent coronary death or non-fatal myocardial infarction. In the present study, we compare results on stored plasma obtained two months after the index myocardial infarction from 1,038 patients of this trial, using a simple automated latex agglutination (LA) assay in parallel with the standard ELISA test. Results show a somewhat higher mean value for the LA assay (702 ± 1092 vs. 638 ± 986 ng/ml, p = 0.0002), a strong linear correlation of the two assays (r = 0.86) and 88% agreement for values below 500 ng/ml by the ELISA test. D-dimer concentrations determined by each assay were highly correlated in patients with subsequent coronary artery events (p = 0.93) and quartile values for both the LA and ELISA were equally predictive of such events (p = 0.003 and p = 0.001, respectively). This is the first demonstration that a latex agglutination assay for D-dimer can be used to assess the prognostic risk of recurrent coronary thrombotic disease after myocardial infarction


1999 ◽  
Vol 81 (04) ◽  
pp. 527-531 ◽  
Author(s):  
U. Kjellberg ◽  
N.-E. Andersson ◽  
S. Rosén ◽  
L. Tengborn ◽  
M. Hellgren

SummaryForty-eight healthy pregnant women were studied prospectively and longitudinally. Blood sampling was performed at 10-15, 23-25, 32-34 and 38-40 weeks of gestation, within one week and at eight weeks postpartum. Classic and modified activated protein C ratio decreased as pregnancy progressed. In the third trimester 92% of the ratios measured with the classic test were above the lower reference level whereas all modified test ratios were normal. Slight activation of blood coagulation was shown with increased levels of prothrombin fragment 1+2, soluble fibrin and D-dimer. Fibrinogen, factor VIII and plasminogen activator inhibitor type 1 and type 2 increased. Protein S and tissue plasminogen activator activity decreased. Protein C remained unchanged. No correlation was found between the decrease in classic APC ratio and changes in factor VIII, fibrinogen, protein S, prothrombin fragment 1+2 or soluble fibrin, nor between the increase in soluble fibrin and changes in prothrombin fragment 1+2, fibrinogen and D-dimer.


Sign in / Sign up

Export Citation Format

Share Document