Automated Latex Agglutination and ELISA Testing Yield Equivalent D-Dimer Results in Patients with Recent Myocardial Infarction

1999 ◽  
Vol 82 (11) ◽  
pp. 1412-1416 ◽  
Author(s):  
Wojciech Zareba ◽  
John Horan ◽  
Arthur Moss ◽  
Joel Kanouse ◽  
◽  
...  

SummaryOur previous prospective study of post-infarction patients described a strong and significant association of increased plasma D-dimer concentrations in those who experienced a subsequent coronary death or non-fatal myocardial infarction. In the present study, we compare results on stored plasma obtained two months after the index myocardial infarction from 1,038 patients of this trial, using a simple automated latex agglutination (LA) assay in parallel with the standard ELISA test. Results show a somewhat higher mean value for the LA assay (702 ± 1092 vs. 638 ± 986 ng/ml, p = 0.0002), a strong linear correlation of the two assays (r = 0.86) and 88% agreement for values below 500 ng/ml by the ELISA test. D-dimer concentrations determined by each assay were highly correlated in patients with subsequent coronary artery events (p = 0.93) and quartile values for both the LA and ELISA were equally predictive of such events (p = 0.003 and p = 0.001, respectively). This is the first demonstration that a latex agglutination assay for D-dimer can be used to assess the prognostic risk of recurrent coronary thrombotic disease after myocardial infarction

1987 ◽  
Author(s):  
F Keller ◽  
P Schanzenbächer ◽  
F Dati ◽  
J Huber ◽  
K kochsiek

The new drug pro-urokinase, a proenzyme of urokinase (scu-PA), seems to have advantages in comparison with other fibrinolytic agents. Properties like higher fibrin specifity, non-systemic activity and lower antigenity may lead to a lower rate of complications. In a pilot study 10 patients with acute myocardial infarction have been treated under angiographical control with pro-urokinase (3-9 millions IU) by i.v. application. In case of no perfusion a further administration of streptokinase was carried on. The blood samples were obtained at therapy begin and after 5, 10, 30, 60 and 120 minutes. The therapy monitoring was performed by determination of established haemostasis parameters, like fibrinogen, fibrin(ogen)-split products (FSP), a2-antiplasmin. Plasminogen and batroxobin-time. Furthermore, the diagnostic relevance of new laboratory tests for fibrinolysis, D-Dimer and thrombin-anti thrombin Ill-complex (TAT) has been investigated considering some typical follow-ups. D-Dimer were determined by latex agglutination test and TAT by enzyme immunoassay.Generally the application of pro-urokinase in contrast to streptokinase results in minimal changes of the classic fibrinolysis parameters like fibrinogen, FSP, batroxobin-time etc. demonstrating no systemic lysis. The appearance of plasmic degradation products of cross-linked fibrin (D-Dimer) is a specific indi-cater of the release of thrombotic material. Other non-specific degradation products (fibrinogenolysis) were detected by the measurement of FSP. In some cases in which perfusion ocurred an increase of TAT followed by a rapid decrease was observed. This indicates a higher thromboplastic activity which may originate from the infarcted area producing TAT complex formation.


1994 ◽  
Vol 71 (03) ◽  
pp. 270-274 ◽  
Author(s):  
Siri Dale ◽  
Geir O Gogstad ◽  
Frank Brosstad ◽  
Hans C Godal ◽  
Jostein Holtlund ◽  
...  

SummaryNinety-two consecutive patients referred for suspicion of deep venous thrombosis (DVT) were analyzed for D-dimer using ELISA, latex test, and a new immunofiltration method (NycoCard D-Dimer). Contrast venography verified the diagnosis in 40, and excluded the diagnosis in 52 patients. The sensitivity, negative predictive values, specificity and positive predictive values were, for ELISA 98%, 95%, 38% and 54, for NycoCard D-Dimer 100%, 100%, 42% and 57% and for the latex test 73%, 78%, 75%, and 69%, respectively. Sensitivity and specificity were inversely related with increasing pathological cutoff value. Comparison of test results by concentration category revealed a good agreement between ELISA and NycoCard D-Dimer, but to less extent between latex and the two other tests. It is concluded that NycoCard D-Dimer and D-dimer ELISA are well-suited as exclusion tests for DVT. A plasma sample is tested with NycoCard D-Dimer in less than 2 min. Thus, this test combines advantageous analytical properties comparable to the ELISA-test, with rapidity and simplicity comparable to the latex test.


1996 ◽  
Vol 76 (04) ◽  
pp. 518-522 ◽  
Author(s):  
A Elias ◽  
I Aptel ◽  
B Huc ◽  
J J Chale ◽  
F Nguyen ◽  
...  

SummaryThe current D-Dimer ELISA methods provide high sensitivity and negative predictive value for the diagnosis of deep vein thrombosis but these methods are not suitable for emergency or for individual determination. We have evaluated the performance of 3 newly available fast D-Dimer assays (Vidas D-Di, BioMerieux; Instant IA D-Di, Stago; Nycocard D-Dimer, Nycomed) in comparison with 3 classic ELISA methods (Stago, Organon, Behring) and a Latex agglutination technique (Stago). One-hundred-and-seventy-one patients suspected of presenting a first episode of deep vein thrombosis were investigated. A deep vein thrombosis was detected in 75 patients (43.8%) by ultrasonic duplex scanning of the lower limbs; in 11 of them the thrombi were distal and very limited in size (<2 cm). We compared the performance of the tests by calculating their sensitivity, specificity, positive and negative predictive value for different cut-off levels and by calculating the area under ROC curves. The concordance of the different methods was evaluated by calculating the kappa coefficient. The performances of the 3 classic ELISA and of the Vidas D-Di were comparable and kappa coefficients indicated a good concordance between the results provided by these assays. Their sensitivity slightly declined for detection of the very small thrombi. Instant IA D-Di had a non-significantly lower sensitivity and negative predictive value than the 4 previous assays; however its performance was excellent for out-patients. As expected, the Latex assay had too low a sensitivity and negative predictive value to be recommended. In our hands, Nycocard D-Dimer also exhibited low sensitivity and negative predictive value, which were significantly improved when the plasma samples were tested by the manufacturer. Thus significant progress has been made, allowing clinical studies to be planned to compare the safety and cost-effectiveness of D-Dimer strategy to those of the conventional methods for the diagnosis of venous thrombosis.


1996 ◽  
Vol 75 (05) ◽  
pp. 772-777 ◽  
Author(s):  
Sybille Albrecht ◽  
Matthias Kotzsch ◽  
Gabriele Siegert ◽  
Thomas Luther ◽  
Heinz Großmann ◽  
...  

SummaryThe plasma tissue factor (TF) concentration was correlated to factor VII concentration (FVIIag) and factor VII activity (FVIIc) in 498 healthy volunteers ranging in age from 17 to 64 years. Immunoassays using monoclonal antibodies (mAbs) were developed for the determination of TF and FVIIag in plasma. The mAbs and the test systems were characterized. The mean value of the TF concentration was 172 ± 135 pg/ml. TF showed no age- and gender-related differences. For the total population, FVIIc, determined by a clotting test, was 110 ± 15% and the factor VIlag was 0.77 ± 0.19 μg/ml. FVII activity was significantly increased with age, whereas the concentration demonstrated no correlation to age in this population. FVII concentration is highly correlated with the activity as measured by clotting assay using rabbit thromboplastin. The ratio between FVIIc and FVIIag was not age-dependent, but demonstrated a significant difference between men and women. Between TF and FVII we could not detect a correlation.


2015 ◽  
Vol 5 (4) ◽  
pp. 269-271
Author(s):  
Falgun Gosai ◽  
Parikh Mital ◽  
Abhishek Vadher ◽  
Pathak Jaya ◽  
Jain Nibha ◽  
...  

PEDIATRICS ◽  
1995 ◽  
Vol 96 (5) ◽  
pp. 951-954
Author(s):  
Penny M. Adcock ◽  
Ronald I. Paul ◽  
Gary S. Marshall

Background. Identifying febrile children with invasive bacterial infection is difficult in the absence of telltale physical findings. Urine latex agglutination (ULA) tests have been used for rapid, on-site identification of such children. Objectives. To study the performance of ULA tests in identifying children with Haemophilus influenzae, Streptococcus pneumoniae, and group B streptococcus infection and to examine how the results of ULA tests affect patient treatment. Design. Retrospective review. Setting. Urban children's hospital. Patients. All emergency department and hospital patients tested by ULA in 1990, excluding patients in the neonatal units. Results. Of 1629 patients, 36 had positive tests (20 H influenzae, 5 S pneumoniae, and 11 group B streptococcus). Thirteen of these were false positive based on culture results. Although ULA tests demonstrated excellent specificity, their sensitivity was poor. Positive predictive values for bacteremia ranged from 0.346 to 0.600, and negative predictive values ranged from 0.972 to 0.997. The decision to treat with antibiotics was made before ULA test results were available in 19 (53%) of the 36 patients with positive test results. Of 1593 patients with negative test results, 1211 (76%) were admitted to the hospital, and approximately 81% were empirically treated with parenteral antibiotics. Conclusions. In clinical practice, treatment and disposition decisions are frequently made without regard to ULA test results.


2007 ◽  
Vol 135 (5-6) ◽  
pp. 306-309 ◽  
Author(s):  
Ivana Radonjic ◽  
Aleksandar Dzamic ◽  
Valentina Arsic-Arsenijevic ◽  
Slobodanka Djukic ◽  
Sanja Mitrovic

Introduction: Cystic echinococcosis is a parasitic zoonosis caused by a tapeworm Echinococcus granulosus. Liver infection is the most common form of human echinococcosis. Diagnosis of liver echinococcosis could be made by different methods. It is very important to have good anamnesis and epidemiological evaluation, clinical status and clinical investigations such as X-ray examination, ultrasonography, nuclear magnetic resonance, computerized tomography, laboratory analysis and serology. Different serologic tests could be used for diagnosis of echinococcosis: complement fixation test, immunoelectrophoresis, indirect haemagglutination, latex agglutination, indirect fluorescence test and enzyme immunoassays sush as ELISA test. Objective. The aim of this study was to investigate anti-E. granulosus antibodies by ELISA test as a complementary laboratory method in the diagnosis of human echinococcosis. Method. In this study, we investigated 212 patients of suspected liver cystic echinococcosis. ELISA test was used for detection of whole anti-E. granulosus IgG antibodies specific for AgB. Results. Out of 212 patients, in 26 (12.26%) patients echinococcosis was confirmed by ELISA test. In 7/26 patients who had data about the ultrasonographic morphological type of cyst according to Gharbi, high values of seropositivity were found. Borderline values were found in 15/212 (7.08%) patients. In three patients with borderline values, second sera samples were examined after 18-22 days. In one patient, the test showed the same value, in the second patient echinococcosis was confirmed while in the third, the test showed a negative value. In 171 (80.66%) patients, anti-Echinococcus antibodies were not found by ELISA test. Conclusion. It has already been known that serological investigation has some limitations, but detection of specific antibodies remains an indispensable mark in evaluation of suspected liver cystic echinococcosis patients. .


Sign in / Sign up

Export Citation Format

Share Document