scholarly journals Effect of Acacia arabica gum on histochemical changes in the renal cortex of rats exposed to gamma radiation

2021 ◽  
Vol 3 (1) ◽  
pp. 1-24
Author(s):  
Heba Kandeal ◽  
Hemmat Abdelhafez ◽  
Fatma Eid ◽  
Amr Abd Elhady
Author(s):  
Kosuke Ueda ◽  
Hiroto Washida ◽  
Nakazo Watari

IntroductionHemoglobin crystals in the red blood cells were electronmicroscopically reported by Fawcett in the cat myocardium. In the human, Lessin revealed crystal-containing cells in the periphral blood of hemoglobin C disease patients. We found the hemoglobin crystals and its agglutination in the erythrocytes in the renal cortex of the human renal lithiasis, and these patients had no hematological abnormalities or other diseases out of the renal lithiasis. Hemoglobin crystals in the human erythrocytes were confirmed to be the first case in the kidney.Material and MethodsTen cases of the human renal biopsies were performed on the operations of the seven pyelolithotomies and three ureterolithotomies. The each specimens were primarily fixed in cacodylate buffered 3. 0% glutaraldehyde and post fixed in osmic acid, dehydrated in graded concentrations of ethanol, and then embedded in Epon 812. Ultrathin sections, cut on LKB microtome, were doubly stained with uranyl acetate and lead citrate.


Author(s):  
K. Cowden ◽  
B. Giammara ◽  
T. Devine ◽  
J. Hanker

Plaster of Paris (calcium sulfate hemihydrate, CaSO4. ½ H2O) has been used as a biomedical implant material since 1892. One of the primary limiting factors of these implants is their mechanical properties. These materials have low compressive and tensile strengths when compared to normal bone. These are important limiting factors where large biomechanical forces exist. Previous work has suggested that sterilization techniques could affect the implant’s strength. A study of plaster of Paris implant mechanical and physical properties to find optimum sterilization techniques therefore, could lead to a significant increase in their application and promise for future use as hard tissue prosthetic materials.USG Medical Grade Calcium Sulfate Hemihydrate Types A, A-1 and B, were sterilized by dry heat and by gamma radiation. Types A and B were additionally sterilized with and without the setting agent potassium sulfate (K2SO4). The plaster mixtures were then moistened with a minimum amount of water and formed into disks (.339 in. diameter x .053 in. deep) in polyethylene molds with a microspatula. After drying, the disks were fractured with a Stokes Hardness Tester. The compressive strengths of the disks were obtained directly from the hardness tester. Values for the maximum tensile strengths σo were then calculated: where (P = applied compression, D = disk diameter, and t = disk thickness). Plaster disks (types A and B) that contained no setting agent showed a significant loss in strength with either dry heat or gamma radiation sterilization. Those that contained potassium sulfate (K2SO4) did not show a significant loss in strength with either sterilization technique. In all comparisons (with and without K2SO4 and with either dry heat or gamma radiation sterilization) the type B plaster had higher compressive and tensile strengths than that of the type A plaster. The type A-1 plaster however, which is specially modified for accelerated setting, was comparable to that of type B with K2SO4 in both compressive and tensile strength (Table 1).


1999 ◽  
Vol 96 (1) ◽  
pp. 143-146 ◽  
Author(s):  
J.-P. Pouget ◽  
J.-L. Ravanat ◽  
T. Douki ◽  
M.-J. Richard ◽  
J. Cadet

1979 ◽  
Vol 18 (01) ◽  
pp. 40-45 ◽  
Author(s):  
M. Malešević ◽  
Lj. Stefanović ◽  
N. Vanlić-Razumenić

The renal radiopharmaceutical preparations 99mTc-DMS and 99mTc-GH were examined chemically, biologically and clinically. Both preparations are of high radiochemical purity. The biodistribution of both preparations was examined in experimental animals at different time intervals, from 15 min to 4 hr; the percentage of incorporation of 99mTc-DMS into kidneys is much higher (29.4% to 52.0%) than that of 99mTc-GH (12.80% to 22.20%). Both preparations accumulate to a greater extent in the renal cortex than in the medulla.The most suitable time for renal scintigraphy for "mTc-DMS is 90-150 min while for 99mTc-GH it is 60-90 min. It is concluded that 99mTc-DMS is more suitable for static scintigrams on the scanner and 99mTc-GH for dynamic studies with the gamma camera.


1965 ◽  
Vol 05 (01) ◽  
pp. 56-67
Author(s):  
I. Pál ◽  
J. Földes ◽  
I. Krasznai

SummaryThe authors investigated the use of 197Hg EDTA complex for kidney scanning. They describe the physical, biological and toxicological properties of the compound; its distribution within the organism, its excretion with urine and faeces and its uptake by the kidneys. The authors have established that the renal cortex selectively secretes the material which makes it suitable for kidney scanning. Some scintigrams of both normal and pathologic kidneys are presented.Finally a detailed discussion of the dosimetry is included. The radiation doses due to 197Hg EDTA are compared with those due to 203Hg-neohydrin and to intravenous pyelography. This comparison shows clearly that the use of 197Hg EDTA considerably decreases the radiation dose to the patient.


2020 ◽  
pp. 8-12
Author(s):  
Alexandr V. Oborin ◽  
Anna Y. Villevalde ◽  
Sergey G. Trofimchuk

The results of development of the national primary standard of air kerma, air kerma rate, exposure, exposure rate and energy flux for X-rays and gamma radiation GET 8-2011 in 2019 are presented according to the recommendations of the ICRU Report No. 90 “Key Data for Ionizing-Radiation Dosimetry: Measurement Standards and Applications”. The following changes are made to the equations for the units determination with the standard: in the field of X-rays, new correction coefficients of the free-air ionization chambers are introduced and the relative standard uncertainty of the average energy to create an ion pair in air is changed; in the field of gamma radiation, the product of the average energy to create an ion pair in air and the electron stopping-power graphite to air ratio for the cavity ionization chambers is changed. More accurate values of the units reproduced by GET 8-2019 are obtained and new metrological characteristics of the standard are stated.


1975 ◽  
Vol 116 (7) ◽  
pp. 517 ◽  
Author(s):  
O.F. Prilutskii ◽  
I.L. Rozental' ◽  
V.V. Usov
Keyword(s):  

Sign in / Sign up

Export Citation Format

Share Document