Modeling of full-scale drinking water treatment plants with embedded plant control

2009 ◽  
Vol 9 (3) ◽  
pp. 253-261 ◽  
Author(s):  
A. W. C. van der Helm ◽  
L. T. J. van der Aa ◽  
K. M. van Schagen ◽  
L. C. Rietveld

In general, the available control actions in drinking water treatment plants are not directly related to the process objectives for water quality. Model based optimization of operation of a drinking water treatment plant by direct control of water quality objectives is discussed. Plant control with PID controllers is embedded in the model of a drinking water treatment plant and the ozonation process in the plant is used as a case study. It is concluded that direct control of water quality objectives, e.g. Giardia inactivation for ozonation, can largely reduce uncertainty and variation in process performance and leads to improvements of drinking water quality. In the discussed case it led to less bromate formation at the same disinfection capacity. Embedded plant control with PID controllers in the model of drinking water treatment plants through the use of code for writing control functionality has a large potential for model based optimization of operation.

2002 ◽  
Vol 2 (5-6) ◽  
pp. 193-199
Author(s):  
M.J. Yu ◽  
H.M. Cho ◽  
J.Y. Koo ◽  
I.S. Han ◽  
E.M. Gwon ◽  
...  

Recently, Seoul city has tried to modify and upgrade the existing facilities and utilities and to improve the established water treatment plants, instead of application of a new treatment process. These efforts have finally lowered the turbidity of finished water below 0.1NTU. Small lab-scale and pilot-scale experiments have been conducted and they have provided optimum parameters for the design and operation of drinking water treatment plants. In addition, quantitative and/or trace analysis technologies developed for monitoring water quality of effluent from unit processes and automization of facilities, have contributed to the improvement of turbidity in drinking water. The Kueui water treatment plant, one of the drinking water treatment plants in Seoul, produces finished water with 0.08 NTU. It results from the operators' continuous endeavor to lower the turbidity in a scale of 0.01 NTU. The data for 12 months indicated that turbidity of settled water was less than 1.16 NTU and that of filtered water was less than 0.12 NTU for 95% of the period. Sedimentation basins and sand filters satisfy the recommended turbidity criteria, 2 NTU and 0.3 NTU, respectively. Also Kueui water treatment plant has focused on the control of organic matters to decrease in DBPs and on the removal of microorganisms.


2019 ◽  
Vol 24 (1) ◽  
pp. 135-163
Author(s):  
Jader Martínez Girón ◽  
Jenny Vanessa Marín-Rivera ◽  
Mauricio Quintero-Angel

Population growth and urbanization pose a greater pressure for the treatment of drinking water. Additionally, different treatment units, such as decanters and filters, accumulate high concentrations of iron (Fe) and manganese (Mn), which in many cases can be discharged into the environment without any treatment when maintenance is performed. Therefore, this paper evaluates the effectiveness of vertical subsurface wetlands for Fe and Mn removal from wastewater in drinking water treatment plants, taking a pilot scale wetland with an ascending gravel bed with two types of plants: C. esculenta and P. australis in El Hormiguero (Cali, Colombia), as an example. The pilot system had three upstream vertical wetlands, two of them planted and the third one without a plant used as a control. The wetlands were arranged in parallel and each formed by three gravel beds of different diameter. The results showed no significant difference for the percentage of removal in the three wetlands for turbidity (98 %), Fe (90 %), dissolved Fe (97 %) and Mn (98 %). The dissolved oxygen presented a significant difference between the planted wetlands and the control. C. esculenta had the highest concentration of Fe in the root with (103.5 ± 20.8) µg/g ; while P. australis had the highest average of Fe concentrations in leaves and stem with (45.7 ± 24) µg/g and (41.4 ± 9.1) µg/g, respectively. It is concluded that subsurface wetlands can be an interesting alternative for wastewater treatment in the maintenance of drinking water treatment plants. However, more research is needed for the use of vegetation or some technologies for the removal or reduction of the pollutant load in wetlands, since each drinking water treatment plant will require a treatment system for wastewater, which in turn requires a wastewater treatment system as well.


2019 ◽  
Vol 19 (8) ◽  
pp. 2330-2337
Author(s):  
Susumu Hasegawa ◽  
Yasuhiro Tanaka ◽  
Naokazu Wake ◽  
Ryosuke Takagi ◽  
Hideto Matsuyama

Abstract Recently, membrane filtration systems have become increasingly common in drinking water treatment plants. In this industry, preventing membrane fouling is of utmost importance. Many studies on the relationship between raw water components and membrane fouling have been performed in laboratory conditions. However, very few studies have analyzed the components of foulants on the fouled membrane as operated in actual drinking water treatment plants. By analyzing these components in plant-conditions, membrane fouling will be more effectively prevented. In this study, we analyzed the components of foulants extracted with 0.1 N NaOH from a fouled membrane operated in a drinking water treatment plant in Japan. Our analysis revealed that the main foulants were humic substances. In order to dissolve the accumulated humic substances, additional chemical cleaning was attempted with 500 ppm sodium hypochlorite. As a result, it was found that humic substances were dissolved and filtration resistance significantly decreased. Additionally, the removal of inorganic foulants was also greater after chemical cleaning with 500 ppm sodium hypochlorite, as inorganic foulants trapped within humic substances were released to the membrane surface as hydroxides by the additional sodium hypochlorite cleaning and were dissolved by the periodic citric acid cleaning.


2008 ◽  
Vol 8 (3) ◽  
pp. 297-304 ◽  
Author(s):  
A. W. C. van der Helm ◽  
L. C. Rietveld ◽  
Th. G. J. Bosklopper ◽  
J. W. N. M. Kappelhof ◽  
J. C. van Dijk

Optimization for operation of drinking water treatment plants should focus on water quality and not on environmental impact or costs. Using improvement of water quality as objective for optimization can lead to new views on operation, design and concept of drinking water treatment plants. This is illustrated for ozonation in combination with biological activated carbon (BAC) filtration at drinking water treatment plant Weesperkarspel of Waternet, the water cycle company for Amsterdam and surrounding areas. The water quality parameters that are taken into account are assimilable organic carbon (AOC), dissolved organic carbon (DOC) and pathogens. The operational parameters that are taken into account are the ozone dosage and the regeneration frequency of the BAC filters. It is concluded that ozone dosage and regeneration frequency should be reduced in combination with application of newly developed insights in design of ozone installations. It is also concluded that a new concept for Weesperkarspel with an additional ion exchange (IEX) step for natural organic matter (NOM) removal will contribute to the improvement of the disinfection capacity of ozonation and the biological stability of the produced drinking water.


2017 ◽  
Vol 18 (1) ◽  
pp. 279-287 ◽  
Author(s):  
E. Bertone ◽  
K. O'Halloran ◽  
M. Bartkow ◽  
K. Mann

Abstract The Mudgeeraba drinking water treatment plant, in Southeast Queensland, Australia, can withdraw raw water from two different reservoirs: the smaller Little Nerang dam (LND) by gravity, and the larger Advancetown Lake, through the use of pumps. Selecting the optimal intake is based on water quality and operators' experience; however, there is potential to optimise this process. In this study, a comprehensive hybrid (data-driven, chemical, and mathematical) intake optimisation model was developed, which firstly predicts the chemicals dosages, and then the total (chemicals and pumping) costs based on the water quality at different depths of the two reservoirs, thus identifying the cheapest option. A second data-driven, probabilistic model then forecasts the volume of the smaller LND 6 weeks ahead in order to minimise the depletion and spill risks. This is important in case the first model identifies this reservoir as the optimal intake solution, but this could lead in the long term to depletion and full reliance on the electricity-dependent Advancetown Lake. Both models were validated and proved to be accurate, and with the potential for substantial monetary savings for the water utility.


Water ◽  
2018 ◽  
Vol 11 (1) ◽  
pp. 57 ◽  
Author(s):  
Abderrezzaq Benalia ◽  
Kerroum Derbal ◽  
Antonio Panico ◽  
Francesco Pirozzi

In this study, the use of acorn leaves as a natural coagulant to reduce raw water turbidity and globally improve drinking water quality was investigated. The raw water was collected from a drinking water treatment plant located in Mila (Algeria) with an initial turbidity of 13.0 ± 0.1 NTU. To obtain acorn leaf powder as a coagulant, the acorn leaves were previously cleaned, washed with tap water, dried, ground and then finely sieved. To improve the coagulant activity and, consequently, the turbidity removal efficiency, the fine powder was also preliminarily treated with different solvents, as follows, in order to extract the coagulant agent: (i) distilled water; (ii) solutions of NaCl (0.25; 0.5 and 1 M); (iii) solutions of NaOH (0.025; 0.05 and 0.1 M); and (iv) solutions of HCl (0.025; 0.05 and 0.1 M). Standard Jar Test assays were conducted to evaluate the performance of the coagulant in the different considered operational conditions. Results of the study indicated that at low turbidity (e.g., 13.0 ± 0.1 NTU), the raw acorn leaf powder and those treated with distilled water (DW) were able to decrease the turbidity to 3.69 ± 0.06 and 1.97 ± 0.03 NTU, respectively. The use of sodium chloride solution (AC-NaCl) at 0.5 M resulted in a high turbidity removal efficiency (91.07%) compared to solutions with different concentrations (0.25 and 1 M). Concerning solutions of sodium hydroxide (AC-NaOH) and hydrogen chloride (AC-HCl), the lowest final turbidities of 1.83 ± 0.13 and 0.92 ± 0.02 NTU were obtained when the concentrations of the solutions were set at 0.05 and 0.1 M, respectively. Finally, in this study, other water quality parameters, such as total alkalinity hardness, pH, electrical conductivity and organic matters content, were measured to assess the coagulant performance on drinking water treatment.


Water ◽  
2019 ◽  
Vol 11 (12) ◽  
pp. 2512 ◽  
Author(s):  
Titus Cooray ◽  
Yuansong Wei ◽  
Junya Zhang ◽  
Libing Zheng ◽  
Hui Zhong ◽  
...  

Installation of decentralized water-treatment plants is an ideal option to supply safe drinking water for rural communities. Presently in Sri Lanka, over 3.6 million villagers face acute water-quality problems, and chronic kidney disease of unknown etiology (CKDu) is also prevalent among this community. Most of the drinking water in these villages is unpalatable due to high hardness and salinity. As an interim measure, reverse-osmosis (RO) water-treatment plants are introduced to provide safe water. However, due to deficient electrolytes, RO-treated water tastes unpleasant to some consumers; hence, people refuse it after prolonged use. The operation, maintenance, and management of RO plants are other major problems. Aimed at providing safe drinking water to the rural sector in a cost-effective manner, in this study, we fabricated an automated drinking-water purification system based on nanofiltration (NF) membrane technology, which can remove divalent cations, dissolved organic carbon (DOC) and pathogens efficiently, and monovalent ions partially, and thus keep electrolytes to some degree. Ten commercial NF membranes were tested in a laboratory, for solute and DOC removal efficiency and robustness. The DF-90 membrane showed the highest removal of DOC and hardness, and it was therefore selected, to design a pilot NF drinking-water treatment plant. The adhered DOC by the membrane can be cleaned by NaOH solution (pH = 12). The pilot NF drinking-water treatment plant has been in use since September 2018, and it shows excellent performance of removing DOC, TDS, hardness, fluoride, and pathogens in groundwater, and the permeate water of the NF plant has been well-accepted by the stakeholders of the society. The dominant genus of source water, and throughout the two processes (NF and RO), is Pseudomonas, and their difference is significant in the concentrates of the NF and RO processes.


Author(s):  
Mohamed Deyab ◽  
Magda El-Adl ◽  
Fatma Ward ◽  
Eman Omar

Abstract This work aims to study the seasonal fluctuation in physicochemical characteristics, trophic status, and some pollutants influencing phytoplankton diversity, and water quality at a compact Kafr El-Shinawy drinking-water treatment plant, Damietta – Egypt seasonally during 2018. Phytoplankton distribution was affected by the trophic status of water, level of pollutants, and physicochemical treatment processes of water. The predominance of phytoplankton species, especially Aphanizomenon flos aquae (Cyanophyta), Gomphosphaeria lacustris (Cyanophyta), Microcystis aeruginosa (Cyanophyta), Nostoc punctiforme (Cyanophyta), Oscillatoria limnetica (Cyanophyta), Pediastrum simplex (Chlorophyta), and Melosira granulata (Bacillariophyta) in treated water was much less than that in raw water. Trihalomethanes (THMs) levels in treated waters were higher than in raw water, while lower concentrations of heavy metals were recorded in treated water. Intracellular levels of microcystins were lower, whereas the extracellular levels were higher in treated water than raw water, and the former recorded the highest level in raw water during summer. Hence, the levels of dissolved microcystins and THMs in treated water were higher especially during summer, the season of luxurious growth of Microcystis species. Trophic state index (TSI) was relatively high in raw water compared with treated water due to high concentrations of nutrients (total-P, total-N, nitrite, nitrate, and ammonia) in raw water.