Nitrification in partially aerated flocculation filters - a full-scale approach

1998 ◽  
Vol 38 (3) ◽  
pp. 135-142
Author(s):  
G. Kolisch

In a full-scale approach, we investigated whether nitrification can be carried out in partially aerated flocculation filters without compromising the removal of suspended solids. The objective is an aerated filter in addition to an advanced nitrification in the main biological treatment step to reduce low NH4-N concentrations in the effluent to very low concentrations. In two separate sets of experiments with an aerated filtering layer of 0.7 m and 1.4 m, nitrification rates up to 14 g N/(m3/h) were achieved. Compared to unaerated chambers, there was approximately the same removal of particulate COD and of precipitated phosphorus compounds. Due to the formation of anoxic zones, nonspecific denitrification occurred in the chambers under both conditions. Decay products are suspected to be the endogenous H-donors.

2019 ◽  
Vol 15 (1) ◽  
pp. 19-27 ◽  
Author(s):  
P. Kängsepp ◽  
M. Sjölin ◽  
A. G. Mutlu ◽  
B. Teil ◽  
C. Pellicer-Nàcher

Abstract The suspended solids (SS) concentrations in effluent from moving bed biofilm reactors (MBBRs) used for secondary biological treatment can be up to 500 mg/L. Microscreens (Drumfilters or Discfilters) can be used as alternatives to traditional clarification or dissolved air flotation to remove SS and total phosphorus (TP). This study shows how a small-scale municipal WWTP for 5,700 population equivalent (PE) can be upgraded to 12,000 PE by combining MBBR with coagulation-flocculation tanks and a Discfilter with a total footprint of 160 m2. This long-term investigation demonstrated that even though influent turbidity (range 146–431 NTU) and flow (25–125 m3/h) varied considerably, very low effluent turbidities (below 10 NTU) could be achieved continuously. Furthermore, this compact treatment system can provide average reductions of ammonium (NH4-N) from 19 to 0.04 mg/L, COD from 290 to 10 mg/L, and TP from 4.5 to 0.3 mg/L. The results show that effluent requirements can be reached by combining MBBR, coagulation-flocculation and disc filtration at full scale, without a primary clarifier upstream of MBBR.


1992 ◽  
Vol 25 (1) ◽  
pp. 17-22 ◽  
Author(s):  
C. Hajipakkos

The suitability of anaerobic digestion for the treatment of a coffee waste has been demonstrated in a full-scale UASB (Upflow Anaerobic Sludge Blanket) plant. The full-scale plant was designed after successful pilot-scale studies (19 m3 reactor) and was commissioned in September 1988. The design was based on a maximum flow of 2000 m3/day, COD concentration of 4000 mg/l, BOD load 3000 kg/day, suspended solids 1500 mg/l and total sulphur 50 mg/l. The temperature of the wastewater was between 28-30 °C. The required final effluent consent conditions for discharge into the local sewer were 700 kg BOD/day, 3000 mg/l COD, 600 mg/l suspended solids and 1 mg/l of hydrogen sulphide. The treatment plant comprised a primary settlement tank, a pre-acidification tank, a UASB reactor and a submerged aerated filter. The first three units were installed so as to obtain the consent conditions in terms of COD, BOD and suspended solids. The submerged aerated filter was constructed in order to meet the hydrogen sulphide consent. Close monitoring of the plant over a period of about 4 months demonstrated the potential of UASB reactors for the pre-treatment of this wastewater, as well as similar wastes from the food industry. A properly designed ventilation system, and de-odourization with compost filters, eliminated all odours emanating from the plant, demonstrating that anaerobic reactors can be safely installed in densely inhabited areas without causing any environmental nuisance.


1998 ◽  
Vol 38 (3) ◽  
pp. 127-134
Author(s):  
Jaap H. J. M. van der Graaf ◽  
Arjen F. van Nieuwenhuijzen

As yet, filtration of wastewater treatment effluent has not been practised in the Netherlands. The main objections were the expected high costs. In order to gain practical experience an investigation programme studied the applicability and optimization of effluent filtration. Especially multi-layer filtration with the addition of ironchloride seemed to be very effective. Very low concentrations of suspended solids and phosphorus were achieved, even at high filtration rates (up to 30 m/h). This leads to an impressive reduction of expected costs, down to Dfl. 0.02/m3 (treated water).


1999 ◽  
Vol 40 (4-5) ◽  
pp. 107-114 ◽  
Author(s):  
A. Kornmüller ◽  
U. Wiesmann

The continuous ozonation of polycyclic aromatic hydrocarbons (PAH) was studied in a two stage ozonation system followed by serobic biological degradation. The highly condensed PAH benzo(e)pyrene and benzo(k)fluoranthene were oxidized selectiely in synthetic oil/water-emulsions. The influence of the ozone mass transfer gas-liquid on the reaction rate of benzo(k)fluoranthene was studied for process optimization. The dissolved ozone concentration is influenced by temperature to a higher degree than the reaction rate of PAH. In dependence on pH, PAH oxidation occurs by a direct reaction with ozone inside the oil droplets. Two main ozonation products of benzo(e)pyrene were quantified at different retention times during ozonation and their transformation could be shown in the biological treatment step.


2014 ◽  
Vol 69 (10) ◽  
pp. 2029-2035 ◽  
Author(s):  
M. Hallberg ◽  
G. Renman ◽  
L. Byman ◽  
G. Svenstam ◽  
M. Norling

The use of road tunnels in urban areas creates water pollution problems, since the tunnels must be frequently cleaned for traffic safety reasons. The washing generates extensive volumes of highly polluted water, for example, more than fivefold higher concentrations of suspended solids compared to highway runoff. The pollutants in the wash water have an affinity for particulate material, so sedimentation should be a viable treatment option. In this study, 12 in situ sedimentation trials were carried out on tunnel wash water, with and without addition of chemical flocculent. Initial suspended solids concentration ranged from 804 to 9,690 mg/L. With sedimentation times of less than 24 hours and use of a chemical flocculent, it was possible to reach low concentrations of suspended solids (<15 mg/L), PAH (<0.1 μg/L), As (<1.0 μg/L), Cd (<0.05 μg/L), Hg (<0.02 μg/L), Fe (<200 μg/L), Ni (<8 μg/L), Pb (<0.5 μg/L), Zn (<60 μg/L) and Cr (<8 μg/L). Acute Microtox® toxicity, mainly attributed to detergents used for the tunnel wash, decreased significantly at low suspended solids concentrations after sedimentation using a flocculent. The tunnel wash water did not inhibit nitrification. The treated water should be suitable for discharge into recipient waters or a wastewater treatment plant.


2012 ◽  
Vol 518-523 ◽  
pp. 2130-2137
Author(s):  
Si Hao Lv ◽  
Hui Chang ◽  
Zhi Hui Liang ◽  
Yan Yan Zeng ◽  
Hong Bo Fan

A pilot study was carried out to evaluate the application of aerobic submerged MBR in treating polyester wastewater and a full scale system in which MBR was adopted as the key aspect was put forward to treat the polyester wastewater of Zhuhai Yuhua Polyester co., Ltd., China. The pilot study revealed that HRT could be affected by the influent COD, and a HRT larger than 36h was proposed for treating polyester wastewater by MBR. Volumetric loading rate and sludge loading rate ranged in 0.7-2.0 kgCOD/m3•d and 0.09~0.24 kgCOD/ kgMLSS•d respectively were of small influence on the COD removal. DO in the range of 2.5-4.0 mg/L seemed to be optimal for avoiding limitations due to oxygen concentration and creating an effective turbulence. The modified full scale system which includes anaerobic digesting tank and MBR followed by a stabilization pond was verified to be effective to treat the polyester wastewater in the latest two years. The results illustrated that the effluent water quality could meet the discharge limits of water pollutants (DB 44/26-2001) which was established in Guangdong, China. Observed sludge yield of the system fluctuated between 0.10-0.18 gMLSS/gCOD and averaged at 0.137 gMLSS/gCOD. The membrane permeate at around 10 L/m2h, TMP of less than 0.7bar, and total mixed liquor suspended solids (MLSS) between 6-7g/L were suitable to operate the MBR.


2012 ◽  
Vol 7 (1) ◽  
Author(s):  
S. S. Fatima ◽  
S. Jamal Khan

In this study, the performance of wastewater treatment plant located at sector I-9 Islamabad, Pakistan, was evaluated. This full scale domestic wastewater treatment plant is based on conventional activated sludge process. The parameters which were monitored regularly included total suspended solids (TSS), mixed liquor suspended solids (MLSS), mixed liquor volatile suspended solids (MLVSS), biological oxygen demand (BOD), and chemical oxygen demand (COD). It was found that the biological degradation efficiency of the plant was below the desired levels in terms of COD and BOD. Also the plant operators were not maintaining consistent sludge retention time (SRT). Abrupt discharge of MLSS through the Surplus Activated sludge (SAS) pump was the main reason for the low MLSS in the aeration tank and consequently low treatment performance. In this study the SRT was optimized based on desired MLSS concentration between 3,000–3,500 mg/L and required performance in terms of BOD, COD and TSS. This study revealed that SRT is a very important operational parameter and its knowledge and correct implementation by the plant operators should be mandatory.


2014 ◽  
Vol 69 (8) ◽  
pp. 1720-1727 ◽  
Author(s):  
E. N. P. Courtens ◽  
F. Meerburg ◽  
V. Mausen ◽  
S. E. Vlaeminck

Water is not enough. Nowadays, numerous chemicals are used for fire extinction. After use, however, these may unintentionally enter sewerage systems. In order to safely treat firefighting wastewater (FFWW), knowledge of the potential effects of these chemicals on biological treatment processes is essential. This study characterized and mimicked the composition of FFWW containing two powders, three foams and one foam degrader. Nitrogen (162–370 mg NH4+-N L−1) and phosphorus (173–320 mg PO43−-P L−1) concentrations exceeded discharge limits, whereas chemical and biological oxygen demand, suspended solids and detergent concentrations remained sufficiently low. Adequate nutrient removal could be obtained through FeCl3 addition and nitrification/denitrification with acetate as substrate. In batch tests, residual nitrifying activities of 84, 81, 89, 95 and 93% were observed in the presence of powders, foams, foam degrader, synthetic and real FFWW, respectively. All categories showed higher denitrification rates than the control. Although the powders at first seemed to inhibit anammox activity at 82%, after pH correction anammox was fully feasible, allowing nitrogen removal through oxygen-limited nitrification/denitrification (OLAND). Detailed cost calculations indicated that OLAND could save 11% of capital and 68% of operational costs compared to nitrification/denitrification, identifying OLAND as the most recommendable process for nitrogen removal from firefighting wastewaters.


Sign in / Sign up

Export Citation Format

Share Document