scholarly journals DEVELOPMENT OF UV SPECTROPHOTOMETRIC METHOD FOR THE DETERMINATION OF BENIDIPINE HYDROCHLORIDE BY USING QUALITY BY DESIGN (QbD) APPROACH

2018 ◽  
Vol 10 (4) ◽  
pp. 92 ◽  
Author(s):  
Manish Kumar ◽  
Ajay Kumar Shukla ◽  
Ram Singh Bishnoi ◽  
C. P. Jain

Objective: To develop a simple, rapid, accurate, robust and inexpensive spectrophotometric method for the estimation of benidipine hydrochloride by using quality by design (QbD)” approach.Methods: A UV spectrophotometric method was developed on Shimadzu UV-1800 double beam spectrophotometer using methanol as solvent and wavelength of 236 nm was selected as absorbance maxima (𝜆max). Effect of input variables on spectrum characteristics were studied for the selection of critical parameters and proposed method was validated for various parameters like system suitability, linearity, precision, accuracy, detection limits and quantification limits as per the International Conference on Harmonization guidelines ICH Q2(R1).Results: Linearity of the method was found to be excellent over the concentration range 3 to 18 µg/ml with high correlation coefficient value of 0.9999. Limits of detection and quantification were found to be 0.20 µg/ml and 0.60 µg/ml respectively. The mean recovery was found to be 100.35 % with low percentage relative standard deviation (% RSD) value. The precision study also has shown low % RSD value (<1). No interfering peaks were observed during specificity studies.Conclusion: Obtained result indicated that the developed spectrophotometric method is robust and efficient for the determination of benidipine hydrochloride.

2021 ◽  
Vol 14 (4) ◽  
pp. 2165-2172
Author(s):  
Deepshi Arora ◽  
Manish Kumar ◽  
Shailendra Bhatt ◽  
Yugam Taneja ◽  
Abhishek Tiwari ◽  
...  

Background: Rivastigmine Tartrate belongs to the class of cholinesterase inhibitors in Anti-alzheimer’s disease with optimum therapeutic efficacy. Till now no validated method of its quantification has been reported in simulated nasal fluid. Objective: The current research investigation aims to develop a rapid, simple, and reliable UV spectrophotometric method for the quantitative determination of the pure form of Rivastigmine Tartrate in SNF. Method: A suitable method was developed by using double beam UV spectrophotometer and selection of a suitable solvent system for estimation of Rivastigmine Tartrate at absorbance maxima 263nm in SNF. The method was validated for various parameters like including accuracy, linearity and precision as per the International Conference on Harmonization guidelines. Results: The method developed by selecting simulated nasal fluid as the solvent system satisfied the optimum condition of the good quality peak at the selected wavelength. The results proposed the developed method for Rivastigmine Tartrate quantification in the simulated nasal fluid to be linear in the working concentration range of 5-60 µg/ml with a co-relation coefficient of 0.998. The % accuracy was found to be 99.8 -100.57. The % RSD values were < 2 while LOD & LOQ values were detected to be 0.316 and 1.053 respectively. Conclusion: The stated method was analyzed to be rapid, accurate, reliable, and precise. Further, it can be used in checking the quality control parameters of the Rivastigmine Tartrate in routine analysis.


2013 ◽  
Vol 6 (1) ◽  
pp. 133-141 ◽  
Author(s):  
S. Binte Amir ◽  
M. A. Hossain ◽  
M. A. Mazid

The present study was undertaken to develop and validate a simple, sensitive, accurate, precise and reproducible UV spectrophotometric method for cefuroxime axetil using methanol as solvent. In this method the simple UV spectrum of cefuroxime axetil in methanol was obtained which exhibits absorption maxima (?max) at 278 nm. The quantitative determination of the drug was carried out at 278 nm and Beer’s law was obeyed in the range of (0.80-3.60) µg/ml. The proposed method was applied to pharmaceutical formulation and percent amount of drug estimated (95.6% and 96%) was found in good agreement with the label claim. The developed method was successfully validated with respect to linearity, specificity, accuracy and precision. The method was shown linear in the mentioned concentrations having line equation y = 0.05x + 0.048 with correlation coefficient of 0.995. The recovery values for cefuroxime axetil ranged from 99.85-100.05. The relative standard deviation of six replicates of assay was less than 2%. The percent relative standard deviations of inter-day precision ranged between 1.45-1.92% and intra-day precision of cefuroxime axetil was 0.96-1.51%. Hence, proposed method was precise, accurate and cost effective.  Keywords: UV-Vis spectrophotometer; Method validation; Cefuroxime axetil; Recovery studies.  © 2013 JSR Publications. ISSN: 2070-0237 (Print); 2070-0245 (Online). All rights reserved.   doi: http://dx.doi.org/10.3329/jsr.v6i1.14879 J. Sci. Res. 6 (1), 133-141 (2013)  


2010 ◽  
Vol 7 (4) ◽  
pp. 1612-1620 ◽  
Author(s):  
M. Keyvanfard ◽  
N. Abedi

A new, simple, sensitive and selective kinetic spectrophotometric method was developed for the determination of ultra trace amounts of vanadium(V). The method is based on the catalytic effect of vanadium(V) on the oxidation of malachite green oxalate (MG) by bromate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in the absorbance of malachite green oxalate (MG) at 625 nm with a fixed-time method. The decrease in the absorbance of MG is proportional to the concentration of vanadium(V) in the range of 1-100 ng/mL with a fixed time of 0.5-2 min from the initiation of the reaction. The limit of detection is 0.71 ng/mL of vanadium(V). The relative standard deviation for the determination of 5, 30, 50 ng/mL of vanadium(V) was2.5% 2.6%, 2.4% and respectively. The method was applied to the determination of vanadium(V) in water samples.


2017 ◽  
Vol 9 (5) ◽  
pp. 102
Author(s):  
Sukhjinder Kaur ◽  
Taranjit Kaur ◽  
Gurdeep Kaur ◽  
Shivani Verma

Objective: The aim of the present work was to develop a simple, rapid, accurate and economical UV-visible spectrophotometric method for the determination of hydroquinone (HQ) in its pure form, marketed formulation as well as in the prepared nanostructured lipid carrier (NLC) systems and to validate the developed method.Methods: HQ was estimated at UV maxima of 289.6 nm in pH 5.5 phosphate buffer using UV-Visible double beam spectrophotometer. Following the guidelines of the International Conference on Harmonization (ICH), the method was validated for various analytical parameters like linearity, precision, and accuracy robustness, ruggedness, limit of detection, quantification limit, and formulation analysis.Results: The obtained results of the analysis were validated statistically. Recovery studies were performed to confirm the accuracy of the proposed method. In the developed method, linearity over the concentration range of 5-40 μg/ml of HQ was observed with the correlation coefficient of 0.998 and found in good agreement with Beer Lambert’s law. The precision (intra-day and inter-day) of the method was found within official RCD limits (RSD<2%).Conclusion: The sensitivity of the method was assessed by determining the limit of detection and limit of quantification. It could be concluded from the results obtained that the purposed method for estimation of HQ in pure form, in the marketed ointment and in the prepared NLC-formulation was simple, rapid, accurate, precise and economical. It can be used successfully in the quality control of pharmaceutical formulations and for the routine laboratory analysis.


2013 ◽  
Vol 2013 ◽  
pp. 1-5
Author(s):  
Mohsen Keyvanfard ◽  
Khadijeh Alizad ◽  
Razieh Shakeri

A new kinetic spectrophotometric method is described for the determination of ultratrace amounts of sodium cromoglycate (SCG). The method based on catalytic action of SCG on the oxidation of amaranth with periodate in acidic and micellar medium. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of the amaranth at 518 nm, for the first 4 min from initiation of the reaction. Calibration curve was linear in the range of 4.0−36.0 ng mL−1SCG. The limit of detection is 2.7 ng mL−1SCG. The relative standard deviation (RSD) for ten replicate analyses of 12, 20, and 28 ng mL−1SCG was 0.40%, 0.32%, and 0.53%, respectively. The proposed method was used for the determination of SCG in biological samples.


2009 ◽  
Vol 2009 ◽  
pp. 1-8 ◽  
Author(s):  
Ibrahim A. Darwish ◽  
Heba H. Abdine ◽  
Sawsan M. Amer ◽  
Lama I. Al-Rayes

Simple and rapid spectrophotometric method has been developed and validated for the determination of paroxetine (PRX) in tablets. The proposed method was based on nucleophilic substitution reaction of PRX with 1,2-naphthoquinone-4-sulphonate (NQS) in an alkaline medium to form an orange-colored product of maximum absorption peak () at 488 nm. The stoichiometry and kinetics of the reaction were studied, and the reaction mechanism was postulated. Under the optimized reaction conditions, Beer's law correlating the absorbance (A) with PRX concentration (C) was obeyed in the range of 1–8 g . The regression equation for the calibration data was: A = 0.0031 + 0.1609 C, with good correlation coefficients (0.9992). The molar absorptivity () was L  1 . The limits of detection and quantitation were 0.3 and 0.8 g , respectively. The precision of the method was satisfactory; the values of relative standard deviations did not exceed 2%. The proposed method was successfully applied to the determination of PRX in its pharmaceutical tablets with good accuracy and precisions; the label claim percentage was %. The results obtained by the proposed method were comparable with those obtained by the official method.


2008 ◽  
Vol 27 (2) ◽  
pp. 149 ◽  
Author(s):  
Ivana Savić ◽  
Goran Nikolić ◽  
Vladimir Banković

Simple, accurate and reproducible UV-spectrophotometric method was developed and validated for the estimation of phenylephrine hydrochloride in pharmaceutical nasal drops formulations. Phenylephrine hydrochloride was estimated at 291 nm in 1 mol⋅dm-3 sodium hydroxide (pH 13.5). Beer’s law was obeyed in the concentration range of 10–100 μg⋅cm−3 (r2 = 0.9990) in the sodium hydroxide medium. The apparent molar absorptivity was found to be 1.63×103 dm3⋅mol−1⋅cm−1. The method was tested and validated for various parameters according to the ICH (International Conference on Harmonization) guidelines. The detection and quantitation limits were found to be 0.892 and 2.969 μg⋅cm−3, respectively. The proposed method was successfully applied for the determination of phenylephrine hydrochloride in pharmaceutical nasal drops formulations. The results demonstrated that the procedure is accurate, precise and reproducible (relative standard deviation < 1 %), while being simple, cheap and less time consuming, and hence can be suitably applied for the estimation of phenylephrine hydrochloride in different dosage forms.


Author(s):  
LIPSA SAMAL ◽  
AMARESH PRUSTY

Objective: The aim of the present work was to develop and validate a simple UV spectroscopic method for the determination of duloxetine, which is a thiophene derivative and a selective neurotransmitter reuptake inhibitor for serotonin, norepinephrine, and to lesser degree dopamine. Methods: The UV Spectrophotometric analysis was performed using Shimadzu UV-1800 and Shimadzu UV-1700 spectrophotometer by using solvent system acetonitrile and water in the ratio of 8:2. Detection was performed at a wavelength of 290 nm. Method validation was carried out according to ICH Q2R1 guidelines by taking the parameters linearity, accuracy, precision, ruggedness, and robustness, LOD and LOQ. Results: The UV Spectrophotometric method was found linear in the range of 10-50 μg/ml. The method was rugged and robust with % relative standard deviation less than 2. The extraction recoveries were found to be higher than 99% in all experimental conditions. Conclusion: Based upon the performance characteristics, the proposed method was found accurate, precise and rapid and suitable for the determination of Duloxetine for routine analysis.


2006 ◽  
Vol 89 (1) ◽  
pp. 139-143 ◽  
Author(s):  
Maria Helena Iha ◽  
Myrna Sabino

Abstract A method was developed and validated in-house for the determination of patulin (PAT), a toxic mold metabolite, in apple juice. The sample was extracted with ethyl acetatehexane and analyzed by liquid chromatography equipped with a C18 column and diode array detector. The mobile phase used for the quantification was waterethanol, at a flow rate of 0.5 mL/min. The method showed a mean recovery of 84.8%, the relative standard deviation obtained in the precision study was &lt;7.7%, the quantification and detection limits were 7 and 3 μg/L, respectively, and the linear range for PAT in apple juice was 2.6650 μg/L. The ruggedness was evaluated by an intralaboratory experiment, in which 5 factors were studied, and only one was found to influence the observed results. The developed method is fast, practical, and simple; the solvents (except hexane) and reagents used were nontoxic. The results of the validation confirmed the efficiency of the method, which is sensitive enough to be used in studies required to quantify PAT in apple juice.


Author(s):  
Jaspreet Kaur ◽  
Daljit Kaur ◽  
Sukhmeet Singh

Objective: A simple, accurate, and selective ultraviolet-spectrophotometric method has been developed for the estimation of febuxostat in the bulk and pharmaceutical dosage forms.Method: The method was developed and validated according to International Conference on Harmonization (ICH Q2 R1) guidelines. The developed method was validated statistically with respect to linearity, range, precision, accuracy, ruggedness, limit of detection (LOD), limit of quantitation (LOQ), and recovery. Specificity of the method was demonstrated by applying different stressed conditions to drug samples such as acid hydrolysis, alkaline hydrolysis, oxidative, photolytic, and thermal degradation.Results: The study was conducted using phosphate buffer pH 6.8 and λmax was found to be 312 nm. Standard plot having a concentration range of 1–10 μg/ml showed a good linear relationship with R2=0.999. The LOD and LOQ were found to be 0.118 μg/ml and 0.595 μg/ml, respectively. Recovery and percentage relative standard deviations were found to be 100.157±0.332% and <2%, respectively.Conclusion: Proposed method was successfully applicable to the pharmaceutical formulations containing febuxostat. Thus, the developed method is found to be simple, sensitive, accurate, precise, reproducible, and economical for the determination of febuxostat in pharmaceutical dosage forms.


Sign in / Sign up

Export Citation Format

Share Document