scholarly journals Comparative Study of Tube in Tube Flat Slab with Tube in Tube Waffle Slab, Structures Under the Sesmic Loads

Author(s):  
Syed Zubair Uddin

Abstract: The tube in tube structure is one of the type that is been broadly used as structural system for tall structures. Considering the lateral loads due to the seismic force it gives more stiffness and gives more strength to the high-rise structures. Lateral loads are shared between the inner and outer tubes our aim is to make the structure stiff by its connectivity and comparing them by providing drops to the waffle. By adding tube in tube to the flat slab and waffle slab, concept is they both does not have the beams such that to know the comparison of both the models. This both models have been designed using e-tabs software and the dimensions, limitations are been taken from the provision Indian standard code book. Keywords: High-rise building, tube in tube, Response spectrum analysis.

2021 ◽  
Vol 6 (2) ◽  
Author(s):  
Mahammad Fayeemuddin ◽  
A. Vimala

The performance of any structure under lateral loads depends on its structural configuration. Most of the codes worldwide mentioned the provisions for the lateral load analysis for regular structures. Structures may be irregular in practice due to uneven distributions in mass, stiffness and strength. In India, most common type of multi-storied apartments constructed varies from 5 to 15 storeys and many apartments are constructed with penthouse which creates mass irregularity in the structures. The present study investigates the performance of mass irregular structures which are created by providing penthouse and also modeled as a stepped setback structure. Total four structures, 5, 7, 11 and 16 storied with an aspect ratio (height to width of the structure) of 0.64, 0.88, 1.36 and 1.96 are considered. For each structure response spectrum analysis is carried and the response parameters like storey displacements, storey drift and base shear variation in 4 seismic zones of India is studied. The main focus of the investigation is to understand the acceptance of mass irregularity with respect to the aspect ratio of the structure. The acceptance limit of the mass irregularity is also investigated as per 4 seismic zones of India. The results are compared with Indian standard code limits and concluded the acceptance limit as per seismic zones of India.


Author(s):  
Md. Shahid Iqbal

Abstract: Structural design and analysis produces the capability of resisting all the applied loads without failure during its intended life. Lateral loads mainly due to earthquake govern the design of high-rise buildings. The interior structural system or exterior structural system provides the resistance to lateral loads in the structure. The present paper describes the analysis and design of high-rise buildings with Steel Plate Shear Wall (SPSW) for (G+20) stories. The properties of Steel plate shear wall system include the stiffness for control of structural displacement, ductile failure mechanism and high-energy absorption. The design and analysis of the composite building with steel plate shear wall is carried out using software ETABS. The present study is to carry out the response spectrum analysis of a high-rise composite building by optimizing the thickness of steel plate shear wall and to compare the results of displacement, story drift, overturning moment and story shear. The models are analyzed by Response Spectrum analysis as per IS 1893:2002. All structural members are designed as per IS 456:2002 & IS 800:2007 considering all load combinations. Keywords: Seismic; Composite; Shear Wall; Earthquake; Reinforced concrete.


2012 ◽  
Vol 594-597 ◽  
pp. 860-868
Author(s):  
Kai Hu ◽  
Ge Qu

The most common analysis methods of complex high-rise buildings are the response spectrum analysis, elastic time history analysis, pushover analysis and etc. Meanwhile, for the analysis of those high-rises whose height is higher than 200 meters, period is longer than 4 seconds, the dynamic nonlinear analysis would be more accurate. In this paper, the dynamic nonlinear analysis was executed in use of the Perform-3D program. The results show that the maximum top displacement can meet the national codes; most tie beams and the frame beams of the upper structure yielded in the IO~IS stage and parts reached the CP stage; both the laminated columns and the frame columns had a good performance on the shear behavior; and it is also proposed to strengthen the reinforcement at the reducted storeys. By all these above, it can be judged that the structure reached the codes’ seismic performance objectives.


Author(s):  
Shaikh Jafar Shaikh Ismail ◽  
L. G. Patil

In present era, there is a huge scarcity of vacant land led to the development of the high rise structures. For the construction of high rise buildings, normal R.C.C. system is not suitable. These problems can overcome by using flat slab system along with shear wall arrangements. It is very essential that the shear wall position should be appropriate in structure so as to achieve the lateral stiffness and solid structure against lateral loads. In this work, two main factors i.e. with drop panels and without drop panels have been considered for 12 storey structures. In each factor 5 models of various locations of shear wall is taken for consideration. For stabilization of variable parameters such as storey displacement, storey stiffness and storey shear etc the seismic investigation & design of structures had carried out in software ETABS. After performing seismic investigation & design of all the structures, result shows that if we provide shear wall at incorrect or inappropriate locations then it will only increase the dead load and cost of the structure. So the final outcomes we have achieved is to provide shear walls at desired position where lateral loads are more predominantly acting on the structures


2021 ◽  
Author(s):  
Natalie Simone Bryon

This study provides an in-depth comparative review of the response reduction factors per NBCC 2015 code used to reduce the elastic response of the structure. An assembly of eight (8) reinforced concrete buildings of which four (4) different Seismic Force Resisting System (SFRS) types was included. The models were also categorized based on ductility and overstrength characteristics specifically ductile and conventional construction moment frames as well as ductile and conventional construction shear walls. All eight (8) models were analyzed using elastic Response Spectrum Analysis (RSA). Each SFRS was also analyzed as both a 12 storey and 40 storey building in order to explore the effects / restrictions of building height. The Equivalent Lateral Force Procedure was performed on the assembly of models for comparison to determine if the static procedure as per NBCC 2015 provisions resulted in overly conservative or similar results. The relevant structural response such as base reactions, storey drifts, storey forces, and member forces were recorded and analyzed.


2018 ◽  
Vol 203 ◽  
pp. 06014
Author(s):  
Zafarullah Nizamani ◽  
Seah Kay Seng ◽  
Akihiko Nakayama ◽  
Mohamad Shariff Bin Omar Khan ◽  
Haider Bilal

Most of the residential buildings in Malaysia are not designed to withstand the seismic forces, while the high-rise buildings. However, since the Sumatra 2004 earthquake, there had been increasing concerns about the structure vulnerability in our country to earthquakes. Several recent studies had also revealed that Malaysia had the possibility to be influenced by both local and far field earthquakes. This study is conducted to analyze the vulnerability of a high rise building to local and far field earthquakes using Scia Engineer. Modal Response Spectrum method of Scia Engineer is used. The model is a 12 story hotel building from Ipoh, Perak. The designing code is the Eurocode with Malaysia Annex. Different Peak Ground Accelerations (PGA) that represents the local and far field earthquakes is acted on the model to obtain the seismic performance. The deformation of the building by the seismic combinations is compared to the ASCE-7 design to evaluate the vulnerability. Research of seismic performance of the flat slab system is also conducted along with beam frame system. The result shows that the building is in a safe condition in terms of deformation and the seismic performance of the flat slab system is advantageous.


In a developing country like India urbanization and industrialization has accelerated real estate development which leds to scarcity of land. This started the construction of multistorey buildings on sloping ground. Buildings constructed on sloping ground are very irregular and unsymmetrical in vertical and horizontal plane as compared to the buildings on level ground. Also, these buildings on sloping ground require great attention for seismic analysis. The present work studies the behavior of flat slab buildings on sloping ground. For this, G+8 storey 36 different building models with square plan area on sloping ground are considered. The total plan area and mass of the building is kept constant for all models. The sloping angles 0°, 16°, 21° are considered for square plan. The corner and core columns of some models are replaced with shear wall by keeping the mass constant. The response spectrum analysis of all models is carried out using software Etabs17. The study concludes that flat slab building with shear wall at outer periphery of building is preferable than the discontinuous shear wall at core of the building.


Author(s):  
Hridya. K

Torsion force is a load that is a applied to a building through torque. The torque applied creates a shear stress. If a torsion force is large enough, it can cause a building to undergo a twisting action. The main aim of the project is to study the effect of location of shear wall on torsional performance of symmetric and asymmetric high-rise building ,post tensioned slabs are being used in the construction of building hence the thesis also analyze these post tensioned slab structures by changing shear wall configuration. Post tensioned slab structures have weak resistance to lateral loads. so to provide stiffness to structures against lateral forces shear walls are used. A study of 30 storey building in zone III, is considered and determine various parameters like base shear, storey drift, and storey displacement.post-tensioning is a mature technology as it provide efficient, economic and elegant structural solutions for a wide range of applications. Post-tensioned flat slab could be a better option compared to RCC flat slab, in respect of the cost of project and time of construction. ETABS 2017 software is used for the analysis.


Nowadays highly increases in the high rise building with architectural requirement in modern city. The purpose of the study is to understand the response of the building due to vertical irregularities. In this paper the incorporated irregularities are as per IS1893 (Part )1:2016 and study response of 12 story building frame 13 models with mass irregular, stiffness irregular and vertical geometric irregularities are analyze in ETABS 2017 by linear dynamic analysis i.e. Response spectrum Analysis. The various structural response parameters such as maximum storey displacement, inter story drift and storey shear are taken to compare the result. Mass irregularity is placed in fourth story, stiffness irregularity is provided in first storey and vertical geometric irregularity is provided in different upper floor. It is concluded that the soft story at bottom highly increases the lateral displacement of that floor, mass irregular at fourth story highly increases the storey shear below that storey and vertical geometric irregularity effect on the relative displacement of building. Combined irregularity highly effect performance of the building therefore chance of collapse also increases as increases in irregularities. All the comparison are represented graphically.


2021 ◽  
Vol 889 (1) ◽  
pp. 012045
Author(s):  
Mir Rahman Naseri ◽  
Balwinder Singh

Abstract A hybrid structure is one that combines more than two different types of materials to compensate for weak places while also maximizing strength. Hybrid steel and concrete frameworks, as well as other modern materials, are unified at the member or framework unit. Hybrid structures are frequent in high-rise and super-high-rise building projects, and they provide the benefit of cost savings. Shear walls are built to withstand lateral loadings like earthquakes and winds loads. The response spectrum analysis approach is frequently used to measure design stresses for earthquake-prone structures. The modelling and analysis of the regular plan structures are done by CSI ETABS 2019 in IV seismic zones, on type II (medium soil) of India According to IS 1893 (Part-1) 2016. The aims of this study Response spectrum analysis of 41 storey RCC and hybrid structures with shear walls and without shear walls are compared. RCC and hybrid structures with shear walls showed lower storey displacement, storey drift, and story shear values than RCC and hybrid structures without shear walls, according to the results of this study. The research results will be helpful as a reference and a tool for seismic analysis of hybrid structures.